17/30354084 DC : 0
NA
Status of Standard is Unknown
BS EN 16855-2 - WALK-IN COLD ROOMS - DEFINITION, THERMAL INSULATION PERFORMANCE AND TEST METHODS - PART 2: CUSTOMIZED COLD ROOMS
Hardcopy , PDF
English
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Performance
6 Methods to assess thermal insulation performances
of customized walk-in cold room components
7 Methods to assess thermal insulation performances
of customized walk-in cold rooms and total power consumption
8 Installation of walk-in cold rooms
9 Factory Production Control (FPC)
Annex A (normative) - Determination of the declared
values of thermal resistance and thermal conductivity
Annex B (normative) - Determination of the aged values
of thermal resistance and thermal conductivity
Annex C (informative) - Walk-in cold rooms documentation
Annex D (informative) - Recommendations on installation
Bibliography
BS EN 16855-2.
Committee |
RHE/19
|
DocumentType |
Draft
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
NA
|
Standards | Relationship |
PREN 16855-2 : DRAFT 2017 | Identical |
EN 12667:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance |
ISO 9972:2015 | Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
EN 14509:2013 | Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
ISO 12491:1997 | Statistical methods for quality control of building materials and components |
EN 12939:2000 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Thick products of high and medium thermal resistance |
EN 13164:2012+A1:2015 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
EN ISO 4590:2016 | Rigid cellular plastics - Determination of the volume percentage of open cells and of closed cells (ISO 4590:2016) |
ISO 4590:2016 | Rigid cellular plastics Determination of the volume percentage of open cells and of closed cells |
EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
EN ISO 6946:2017 | Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12) |
EN ISO 14683:2017 | Thermal bridges in building construction - Linear thermal transmittance - Simplified methods and default values (ISO 14683:2017) |
ISO 12572:2016 | Hygrothermal performance of building materials and products Determination of water vapour transmission properties Cup method |
EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN ISO 12572:2016 | Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572:2016) |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN ISO 10211:2017 | Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2017) |
EN 13165:2012+A2:2016 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
EN 13167:2012+A1:2015 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
ISO 9001:2015 | Quality management systems — Requirements |
EN 12865:2001 | Hygrothermal performance of building components and building elements - Determination of the resistance of external wall systems to driving rain under pulsating air pressure |
EN 13163:2012+A2:2016 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
EN ISO 9972:2015 | Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method (ISO 9972:2015) |
NFP 75 401-1 : 2001 | BUILDING WORKS - THERMAL INSULATION OF REFRIGERATING BUILDINGS AND OF REGULATED TEMPERATURE PREMISES - PART 1: CONTRACT BILL OF TECHNICAL CLAUSES |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
EN 12086:2013 | Thermal insulating products for building applications - Determination of water vapour transmission properties |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
ISO 14683:2017 | Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.