16/30337938 DC : 0
NA
Status of Standard is Unknown
BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS
Hardcopy , PDF
English
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 HV shore supply system requirements
6 Shore side installation
7 Ship to shore connection and interface
equipment
8 Ship requirements
9 HVSC system control and monitoring
10 Verification and testing
11 Periodic tests and maintenance
12 Documentation
Annex A (informative) - Ship to shore connection
cable
Annex B (normative) - Additional requirements for
Roll-on Roll-off (Ro-Ro) cargo ships and Ro-Ro
passenger ships
Annex C (normative) - Additional requirements for cruise
ships
Annex D (normative) - Additional requirements of container
ships
Annex E (informative) - Additional requirements of liquefied
natural gas carriers (LNGC)
Annex F (normative) - Additional requirements for tankers
Bibliography
BS EN 80005-1.
Committee |
SME/32
|
DocumentType |
Draft
|
Pages |
72
|
PublisherName |
British Standards Institution
|
Status |
NA
|
IEEE 519-2014 REDLINE | IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems |
IEEE 1202-2006 | IEEE Standard for Flame-Propagation Testing of Wire & Cable |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
EN 50363-10-2:2005 | Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane |
IEC 60228:2004 | Conductors of insulated cables |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEEE 32-1972 | IEEE Standard Requirements, Terminology, and Test Procedures for Neutral Grounding Devices |
MIL-PRF-29504-5 Revision E:2016 | TERMINI, FIBER OPTIC, CONNECTOR, REMOVABLE, ENVIRONMENT RESISTING, SOCKET TERMINUS, SIZE 16, REAR RELEASE, MIL-DTL-38999, SERIES 3 |
IEEE 1662-2008 | IEEE Guide for the Design and Application of Power Electronics in Electrical Power Systems on Ships |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEEE C37.100.1-2007 | IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V |
IEC 60793-2:2015 | Optical fibres - Part 2: Product specifications - General |
IEC 62613-1:2011 | Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-Systems) - Part 1: General requirements |
ISO 4649:2017 | Rubber, vulcanized or thermoplastic — Determination of abrasion resistance using a rotating cylindrical drum device |
IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEEE C37.20.2-2015 | IEEE Standard for Metal-Clad Switchgear |
IEC 60204-11:2000 | Safety of machinery - Electrical equipment of machines - Part 11: Requirements for HV equipment for voltages above 1 000 V a.c. or 1 500 V d.c. and not exceeding 36 kV |
IEEE 1547-2003 | IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems |
IEEE 1299/C62.22.1 : 1996 | GUIDE FOR THE CONNECTION OF SURGE ARRESTERS TO PROTECT INSULATED, SHIELDED ELECTRIC POWER CABLE SYSTEMS |
IEC 60092-504:2016 | Electrical installations in ships - Part 504: Automation, control and instrumentation |
IMO IF110 : 2014 SUPP 2016 | SOLAS CONSOLIDATED EDITION |
IEC 61363-1:1998 | Electrical installations of ships and mobile and fixed offshore units - Part 1: Procedures for calculating short-circuit currents in three-phase a.c. |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
MIL-STD-464 Revision C:2010 | ELECTROMAGNETIC ENVIRONMENTAL EFFECTS REQUIREMENTS FOR SYSTEMS |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEEE C37.20.3-2013 REDLINE | IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV) |
IEC 62613-2:2016 | Plugs, socket-outlets and ship couplers for high-voltage shore connection systems (HVSC-systems) - Part 2: Dimensional compatibility and interchangeability requirements for accessories to be used by various types of ships |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEEE 80-2013 REDLINE | IEEE Guide for Safety in AC Substation Grounding |
MIL-DTL-38999 Revision M:2015 | Connectors, Electrical, Circular, Miniature, High Density, Quick Disconnect (Bayonet, Threaded or Breech Coupling), Environment Resistant with Crimp Removable Contacts or Hermetically Sealed with Fixed, Solderable Contacts, General Specification for |
IEEE 142 : 2007 | GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
IEC 60092-502:1999 | Electrical installations in ships - Part 502: Tankers - Special features |
MIL-STD-1560 Revision C:2015 | INSERT ARRANGEMENTS FOR MIL-DTL-38999, MIL-DTL-27599 AND SAE-AS29600 SERIES A - ELECTRICAL CIRCULAR CONNECTORS |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60092-301:1980 | Electrical installations in ships - Part 301: Equipment - Generators and motors |
IEC 60092-509:2011 | Electrical installations in ships - Part 509: Operation of electrical installations |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEC 60092-101:1994+AMD1:1995 CSV | Electrical installations in ships - Part 101: Definitions and general requirements |
MIL HDBK 1025/10 : 0 | SAFETY OF ELECTRICAL TRANSMISSION AND DISTRIBUTION SYSTEMS |
MIL-STD-1399-680 Base Document:2008 | HIGH VOLTAGE ELECTRIC POWER, ALTERNATING CURRENT |
IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60092-503:2007 | Electrical installations in ships - Part 503: Special features - AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |