15/30288999 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
BS 7273-4 - CODE OF PRACTICE FOR THE OPERATION OF FIRE PROTECTION MEASURES - PART 4: ACTUATION OF RELEASE MECHANISMS FOR DOORS
Hardcopy , PDF
06-30-2015
English
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Categories of actuation
5 Exchange of information and definition of responsibilities
6 Variations from the recommendations of this standard
7 Methods of actuation
8 Mechanisms for unlocking and release of doors
9 Interface design
10 Monitoring, integrity and reliability of actuation arrangements
11 Manual release controls
12 Special considerations for the design of any associated
fire detection and fire alarm system
13 Power supplies
14 Cables, wiring and other interconnections
15 Acoustically-actuated systems
16 Radio-actuated systems
17 Electromagnetic compatibility
18 Electrical safety
19 Door signage
20 Commissioning
Annexes
Annex A (informative) - Applications for mechanisms for unlocking
and releasing doors
Annex B (normative) - Selection of category of actuation
Annex C (informative) - Typical actuation arrangements for
release mechanisms
Annex D (informative) - Example of a suitable sign for a manual
release control
Annex E (informative) - The advantages and disadvantages
of acoustic actuation of release mechanisms
Annex F (informative) - The advantages and disadvantages of
radio actuation of release mechanisms
Annex G (informative) - Model commissioning certificate
Bibliography
BS 7273-4.
Committee |
FSH/12/4
|
DocumentType |
Draft
|
Pages |
59
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
BS 4678-4:1982 | Cable trunking Specification for cable trunking made of insulating material |
BS EN 61386-1:2008 | Conduit systems for cable management General requirements |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
BS EN ISO 9001:2015 | Quality management systems. Requirements |
BS EN 1155:1997 | Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods |
BS EN 12209:2016 | Building hardware. Mechanically operated locks and locking plates. Requirements and test methods |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
1989/336/EEC : 1989 | COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
BS EN 50133-2-1:2000 | Alarm systems. Access control systems for use in security applications. General requirements for components |
EN 300 220-3 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT TO BE USED IN THE 25 MHZ TO 1 000 MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 MW; PART 3: HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE |
BS EN 54-2 : 1998 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
BS EN 14637:2007 | Building hardware. Electrically controlled hold-open systems for fire/smoke door assemblies. Requirements, test methods, application and maintenance |
BS EN 50172:2004 | Emergency escape lighting systems |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
EN 300 220-2 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1 000 MHZ - PART 2: HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM FOR NON SPECIFIC RADIO EQUIPMENT |
BS EN 16005:2012 | Power operated pedestrian doorsets. Safety in use. Requirements and test methods |
119999/5/EC : 1999 | DIRECTIVE 1999/5/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 1999 ON RADIO EQUIPMENT AND TELECOMMUNICATIONS TERMINAL EQUIPMENT AND THE MUTUAL RECOGNITION OF THEIR CONFORMITY |
BS EN 60702-1 : 2002 | MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES |
BS 4422:2005 | Fire. Vocabulary |
BS EN 1527:2013 | Building hardware. Hardware for sliding doors and folding doors. Requirements and test methods |
BS 5266-8(2004) : 2004 | EMERGENCY ESCAPE LIGHTING SYSTEMS |
BS EN 1838:2013 | Lighting applications. Emergency lighting |
EN 300 220-1 : 2.4.1 | SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT |
BS EN 54-11:2001 | Fire detection and fire alarm systems Manual call points |
BS EN 60839-11-1:2013 | Alarm and electronic security systems Electronic access control systems. System and components requirements |
BS 476-22:1987 | Fire tests on building materials and structures Method for determination of the fire resistance of non-loadbearing elements of construction |
BS EN 14846:2008 | Building hardware. Locks and latches. Electromechanically operated locks and striking plates. Requirements and test methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.