13/30277457 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 1776 - GAS INFRASTRUCTURE - GAS MEASURING SYSTEMS - FUNCTIONAL REQUIREMENTS
Hardcopy , PDF
12-31-2015
English
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 Basic requirements for measuring systems
6 Energy Determination
7 Design of gas measuring system
8 Construction of a gas measuring installation
9 Testing of the gas measuring installation/station
10 Pre-commissioning and commissioning of the gas
measuring installation
11 Operation and maintenance
12 Decommissioning
Annex A (informative) - Guideline for the selection
of meters
Annex B (informative) - Sensor test procedures
Annex C (informative) - Set of formulae to calculate
volume or mass to energy
Annex D (informative) - Uncertainty calculations for the
energy determination
Annex E (informative) - Examples of the assessment of
conformity of the metrological performance
of a gas measuring system taken from England
and the Netherlands
Annex F (informative) - Documentations and records
Annex G (informative) - Typical examples of positions of
gas measuring installations
Bibliography
BS EN 1776.
Committee |
GSE/33/-/5
|
DocumentType |
Draft
|
Pages |
90
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 1776 : DRAFT 2013 | Identical |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
ISO 9004-1:1994 | Quality management and quality system elements Part 1: Guidelines |
EN 12327:2012 | Gas infrastructure - Pressure testing, commissioning and decommissioning procedures - Functional requirements |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
EN ISO 15796:2008 | Gas analysis - Investigation and treatment of analytical bias (ISO 15796:2005) |
ISO 10715:1997 | Natural gas — Sampling guidelines |
EN 15001-1:2009 | Gas Infrastructure - Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations - Part 1: Detailed functional requirements for design, materials, construction, inspection and testing |
EN 12405-1:2005+A2:2010 | Gas meters - Conversion devices - Part 1: Volume conversion |
EN ISO 13443:2005 | Natural gas - Standard reference conditions (ISO 13443:1996 including Corrigendum 1:1997) |
EN 12007-3:2015 | Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 3: Specific functional requirements for steel |
EN ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003) |
ISO 6976:2016 | Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition |
EN 1775:2007 | Gas supply - Gas pipework for buildings - Maximum operating pressure less than or equal to 5 bar - Functional recommendations |
ISO 15971:2008 | Natural gas Measurement of properties Calorific value and Wobbe index |
EN 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
ISO 10723:2012 | Natural gas — Performance evaluation for analytical systems |
EN 12007-1:2012 | Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 1: General functional requirements |
ISO 15796:2005 | Gas analysis — Investigation and treatment of analytical bias |
EN 13463-1:2009 | Non-electrical equipment for use in potentially explosive atmospheres - Part 1: Basic method and requirements |
EN 1594:2013 | Gas infrastructure - Pipelines for maximum operating pressure over 16 bar - Functional requirements |
2004/22/EC : 2004 | DIRECTIVE 2004/22/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 31 MARCH 2004 ON MEASURING INSTRUMENTS |
EN 24006:1993 | Measurement of fluid flow in closed conduits - Vocabulary and symbols (ISO 4006:1991) |
ISO 12213-3:2006 | Natural gas Calculation of compression factor Part 3: Calculation using physical properties |
ISO/IEC Guide 98-4:2012 | Uncertainty of measurement Part 4: Role of measurement uncertainty in conformity assessment |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
ISO 6975:1997 | Natural gas — Extended analysis — Gas-chromatographic method |
EN ISO 9002:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR PRODUCTION AND INSTALLATION |
EN 15001-2:2008 | Gas infrastructure - Gas installation pipework with an operating pressure greater than 0,5 bar for industrial installations and greater than 5 bar for industrial and non-industrial installations - Part 2: Detailed functional requirements for commissioning, operation and maintenance |
EN ISO 9003:1994/AC:1997 | QUALITY SYSTEMS - SPECIFICATION FOR FINAL INSPECTION AND TEST |
EN ISO 9000-1 : 1994 | QUALITY MANAGEMENT AND QUALITY ASSURANCE STANDARDS - PART 1: GUIDELINES FOR SELECTION AND USE (ISO 9000-1:1994) |
ISO 6143:2001 | Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures |
ISO 5167-2:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 2: Orifice plates |
ISO 15970:2008 | Natural gas Measurement of properties Volumetric properties: density, pressure, temperature and compression factor |
EN ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003) |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN ISO 9004-1 : 1994 | QUALITY SYSTEMS - PRINCIPAL CONCEPTS AND APPLICATIONS - GUIDE TO QUALITY MANAGEMENT AND QUALITY SYSTEM ELEMENTS |
ISO 5167-1:2003 | Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
EN 334:2005+A1:2009 | Gas pressure regulators for inlet pressures up to 100 bar |
PREN 12405-3 : DRAFT 2013 | GAS METERS - CONVERSION DEVICES - PART 3: FLOW COMPUTER |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO 9001:2015 | Quality management systems — Requirements |
EN 1359:2017 | Gas meters - Diaphragm gas meters |
EN 12007-2:2012 | Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 2: Specific functional requirements for polyethylene (MOP up to and including 10 bar) |
OIML R 137-1 & 2 : 2012 AMD 2014 | GAS METERS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
ISO 9003:1994 | Quality systems Model for quality assurance in final inspection and test |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
CEN/CLC/ETSI/TR 50572 : 2011 | FUNCTIONAL REFERENCE ARCHITECTURE FOR COMMUNICATIONS IN SMART METERING SYSTEMS |
ISO 15112:2011 | Natural gas Energy determination |
EN 60079-17:2014 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
EN 12007-4:2012 | Gas infrastructure - Pipelines for maximum operating pressure up to and including 16 bar - Part 4: Specific functional requirements for renovation |
ISO 17089-1:2010 | Measurement of fluid flow in closed conduits - Ultrasonic meters for gas Part 1: Meters for custody transfer and allocation measurement |
EN ISO 12213-2:2009 | Natural gas - Calculation of compression factor - Part 2: Calculation using molar-composition analysis (ISO 12213-2:2006) |
EN ISO 12213-1:2009 | Natural gas - Calculation of compression factor - Part 1: Introduction and guidelines (ISO 12213-1:2006) |
ISO 6141:2015 | Gas analysis Contents of certificates for calibration gas mixtures |
ISO 12213-2:2006 | Natural gas Calculation of compression factor Part 2: Calculation using molar-composition analysis |
EN 12405-2:2012 | Gas meters - Conversion devices - Part 2: Energy conversion |
EN 14236:2007 | Ultrasonic domestic gas meters |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
ISO 9000-1:1994 | Quality management and quality assurance standards — Part 1: Guidelines for selection and use |
EN ISO 9000:2015 | Quality management systems - Fundamentals and vocabulary (ISO 9000:2015) |
EN 16314:2013 | Gas meters - Additional functionalities |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
ISO 17089-2:2012 | Measurement of fluid flow in closed conduits - Ultrasonic meters for gas — Part 2: Meters for industrial applications |
EN 12186:2014 | Gas infrastructure - Gas pressure regulating stations for transmission and distribution - Functional requirements |
ISO 6974:1984 | Natural gas — Determination of hydrogen, inert gases and hydrocarbons up to C8 — Gas chromatographic method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.