• Shopping Cart
    There are no items in your cart

11/30217192 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS

Available format(s)

Hardcopy , PDF

Superseded date

06-30-2014

Superseded by

BS EN ISO 4064-2:2017

Language(s)

English

US$57.30
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Terminology
4 Reference conditions
5 Symbols, units and equations
6 External examination
7 Performance tests for all water meters
8 Performance tests related to influence factors and
   disturbances
9 Test programme for type approval
10 Tests for initial verification
11 Presentation of results
Annex A (normative) - Type examination and testing
        of checking facilities of electronic devices
Annex B (normative) - Calculating the relative error
        (of indication) of a water meter
Annex C (normative) - Installation requirements for
        flow disturbance tests
Annex D (normative) - Type evaluation of a family of
        water meters
Annex E (informative) - Examples of methods and
        components used for testing concentric
        water meters
Annex F (informative) - Determining the density of water
Annex G (informative) - Maximum uncertainties in the
        measurement of influence factors and
        disturbances
Annex H (informative) - Pressure loss test pressure
        tappings, hole and slot details
Annex I (normative) - Flow disturbers
Bibliography

BS EN ISO 4064-2

Committee
CPI/30/7
DocumentType
Draft
Pages
114
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

OIML R 49-3 : 2013 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST REPORT FORMAT
OIML G 13 : 1989 PLANNING OF METROLOGY AND TESTING LABORATORIES
OIML D 11 : 2013 GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 60068-3-1:2011 Environmental testing - Part 3-1: Supporting documentation and guidance - Cold and dry heat tests
ISO 4064-4:2014 Water meters for cold potable water and hot water — Part 4: Non-metrological requirements not covered in ISO 4064-1
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60068-2-31:2008 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
ISO 4064-3:2014 Water meters for cold potable water and hot water — Part 3: Test report format
IEC 60068-2-64:2008 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
OIML B 3 : 2011 OIML BASIC CERTIFICATE SYSTEM FOR OIML TYPE EVALUATION OF MEASURING INSTRUMENTS
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60068-3-8:2003 Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC TR 61000-2-1:1990 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems
IEC 61000-2-2:2002+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems
OIML R 49-1 : 2013 WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-3-4:2001 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests
IEC 61000-4-29:2000 Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
ISO 4064-1:2014 Water meters for cold potable water and hot water Part 1: Metrological and technical requirements
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.