08/30184557 DC : DRAFT JUNE 2008
Current
Current
The latest, up-to-date edition.
BS EN 62271-111 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 111: PAD-MOUNTED, DRY VAULT, AND SUBMERSIBLE AUTOMATIC CIRCUIT RECLOSERS AND FAULT INTERRUPTERS FOR ALTERNATING CURRENT SYSTEMS UP TO 38 KV
Published date
11-23-2012
Publisher
Sorry this product is not available in your region.
BS EN 62271-111
| Committee |
PEL/17/1
|
| DocumentType |
Draft
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
| IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
| IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
| IEEE C37.90-2005 | IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus |
| IEC 60502:1994 | Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV |
| IEEE 386-2016 REDLINE | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
| IEEE 4-2013 | IEEE Standard for High-Voltage Testing Techniques |
| IEEE C37.90.3-2001 | IEEE Standard Electrostatic Discharge Tests for Protective Relays |
| IEC 60255-22-6:2001 | Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields |
| IEC 60255-22-3:2007 | Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity |
| IEEE C63.2-2009 | American National Standard for Electromagnetic Noise and Field Strength Instrumentation, 10 Hz to 40 GHz Specifications |
| IEEE C37.90.2:2004 | WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS |
| IEEE C37.06-2009 | AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES |
| IEEE C37.90.1-2012 | IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus |
| IEC 60255-22-2:2008 | Measuring relays and protection equipment - Part 22-2: Electrical disturbance tests - Electrostatic discharge tests |
| IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
| IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
| IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
| IEEE C37.41-2008 REDLINE | IEEE Standard Design Tests for High-Voltage (>1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with These Devices |
| IEEE C37.04-1999 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers |
| IEEE C57.12.28-2014 | IEEE Standard for Pad-Mounted Equipment--Enclosure Integrity |
| IEC 60255-22-4:2008 | Measuring relays and protection equipment - Part 22-4: Electrical disturbance tests - Electrical fast transient/burst immunity test |
Summarise
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Sorry this product is not available in your region.