• Shopping Cart
    There are no items in your cart

(INACTIVE RECORD)IEEE C50.12 : 2005

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

SALIENT-POLE 50 HZ AND 60 HZ SYNCHRONOUS GENERATORS AND GENERATOR/MOTORS FOR HYDRAULIC TURBINE APPLICATIONS RATED 5 MVA AND ABOVE

Withdrawn date

10-18-2023

Published date

01-01-2005

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
   Cooling classification
   Coolant types
4 Operational requirements
   4.1 Service conditions and steady-state duty
   4.2 Transient event and emergency duty requirements
   4.3 Service environment
5 Rating and performance characteristics
   5.1 Output rating
   5.2 Capability
   5.3 Stator voltage rating
   5.4 Power factor and reactive power capability
   5.5 Rotor voltage ratings
   5.6 Short-circuit ratio
   5.7 Transient and subtransient reactances
   5.8 Voltage wave shape
   5.9 Torques
6 Insulation systems
   6.1 Insulation systems defined
   6.2 Classes of insulation systems
   6.3 The use of different classes of insulation systems
7 Temperatures and temperature limits
   7.1 Temperature limits
   7.2 Methods of temperature determination
   7.3 Locations of embedded temperature detectors
   7.4 Location of coolant temperature detectors
8 Efficiency
   8.1 Methods
   8.2 Reference conditions
   8.3 Types of losses
   8.4 Test tolerance on losses
9 Tests
   9.1 Categories and scope of tests
   9.2 Test procedural requirements
   9.3 Heat exchanger testing
   9.4 Testing high-voltage terminal bushings
10 Marking
   10.1 Nameplate
   10.2 Other marking
   10.3 Terminal markings
Annex A (informative) Bibliography
Annex B (normative) TIF weighting factors

Pertains to all types of 50 Hz and 60 Hz salient-pole synchronous generators and generator/motors rated 5 MVA and above to be used for hydraulic turbine or hydraulic pump/turbine applications.

DevelopmentNote
Supersedes IEEE DRAFT C50.12. (02/2006) Supersedes ANSI C50.12. (10/2007)
DocumentType
Standard
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
Supersedes

IEEE 1095-2012 REDLINE IEEE Guide for the Installation of Vertical Generators and Generator/Motors for Hydroelectric Applications
IEEE 1665 : 2009 GUIDE FOR THE REWIND OF SYNCHRONOUS GENERATORS, 50 HZ AND 60 HZ, RATED 1 MVA AND ABOVE
IEEE 810-2015 IEEE Standard for Hydraulic Turbine and Generator Shaft Couplings and Shaft Runout Tolerances
IEEE 434-2006 IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above
IEEE DRAFT C37.102 : D8 2006 AC GENERATOR PROTECTION
IEEE C37.102-2006 REDLINE IEEE Guide for AC Generator Protection
IEEE 1547-2003 IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems
IEEE 421.6-2017 IEEE Recommended Practice for the Specification and Design of Field Discharge Equipment for Synchronous Machines
IEEE 1129-2014 IEEE Guide for Online Monitoring of Large Synchronous Generators (10 MVA and Above)
IEEE C62.92.2-1989 IEEE Guide for the Application of Neutral Grounding in Electrical Utility Systems, Part II - Grounding of Synchronous Generator Systems
IEEE C37.246-2017 IEEE Guide for Protection Systems of Transmission-to-Generation Interconnections

IEEE C37.102-2006 REDLINE IEEE Guide for AC Generator Protection
IEEE 434-2006 IEEE Guide for Functional Evaluation of Insulation Systems for AC Electric Machines Rated 2300 V and Above
NEMA MG 1 : 2016 MOTORS AND GENERATORS
IEC 60034-3:2007 Rotating electrical machines - Part 3: Specific requirements for synchronous generators driven by steam turbines or combustion gas turbines
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
ISO 7919-5:2005 Mechanical vibration Evaluation of machine vibration by measurements on rotating shafts Part 5: Machine sets in hydraulic power generating and pumping plants
IEEE 1310-2012 REDLINE IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines
ISO 3746:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane
IEEE 95-2002 IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage
IEEE 115-2009 REDLINE IEEE Guide for Test Procedures for Synchronous Machines Part I—Acceptance and Performance Testing Part II—Test Procedures and Parameter Determination for Dynamic Analysis
IEEE 1434-2014 IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEEE 43-2013 REDLINE IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery
IEEE 286-2000 IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.