WC 3-1992
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
RUBBER-INSULATED WIRE AND CABLE FOR THE TRANSMISSION AND DISTRIBUTION OF ELECTRICAL ENERGY
01-11-2000
12-01-2013
Foreword
PART 1 - GENERAL
Scope
General Information
Information to Be Supplied to Purchaser
PART 2 - CONDUCTORS
Wires, Physical and Electrical Properties
Solid Conductors
Stranded Conductors
Conductor Size Units
Conductor DC Resistance per Unit Length
Conductor Diameter
Stress Control Layer
PART 3 - INSULATION
Material
Insulation Thicknesses
Additional Insulation Thickness for non-sheathed
Submarine Cables
Series Lighting Circuits
Repairs
Insulation Grades and Requirements
Synthetic Rubber, Moisture Resisting, 60 deg C
Natural Rubber, 60 deg C
Synthetic Rubber, 75 deg C
Synthetic Rubber, Heat Resisting, 75 deg C or Moisture
Resisting 60 deg C
Natural Rubber 75 deg C
Synthetic Rubber, Heat and Moisture Resisting, 75 deg C
Ozone-resisting Natural or Synthetic Rubber
Ozone-resisting Butyl Rubber
Synthetic Rubber, 90 deg C
Ozone-resisting Silicone Rubber
Chlorosulfonated Polyethylene
PART 4 - SHIELDING AND COVERINGS
Shielding
Tapes, Braids, Wraps, and Servings
Jackets
PART 5 - ASSEMBLY, FILLERS, BINDERS, AND CONDUCTOR
IDENTIFICATION
Assembly of Multiple-conductor Cables
Multiple-conductor Round Cables
Flat Twin Cables
Fillers
Binder
Conductor Identification
PART 6 - TESTING AND TEST METHODS
Testing
Tests on Samples
Conductor Test Methods
Test Samples and Specimens for Physical and Aging Tests
Short-time Dielectric Strength Test on Insulation
Conductors
Cold Bending and Long-time Dielectric Strength Test
Capacity and Power Factor Tests
Ozone Resisting Tests
Accelerated Water Absorption Tests
Thickness of Tapes
Measurements of Braids
Determination of Yarn Size of Wraps
Braided Cables for Indoor Installations
Saturant for Fibrous Covering for Aerial Cables
Braided Cables for Outdoor Installations
Saturant for Fibrous Covering for Aerial Cables
Braided Cables for Outdoor Installations
Fibrous or Composite Jackets
Thickness of Metallic Sheaths
Thickness of Jute Beddings and Servings
Tests for Thermoplastic Jackets
Tests for Discharge-resisting Jackets
Volume Resistivity
Stripping Test
Retests for Tests on Samples (Except Physical and Aging
Tests)
Voltage Tests
Insulation Resistance
Partial Discharge Test Procedure
Method for Flexibility Test for Continuously Corrugated
Armor
Method for Determining Permittivity (SIC) and Dielectric
Strength of Exuded Nonconducting Polymeric Stress
Control Layers
PART 7 - CONSTRUCTIONS OF SPECIFIC TYPES
Mine Power Cables
Preassembled Aerial Cables
Portable Arc-welding Cables
Control Cables
Primary Underground Residential Distribution Cables -
Butyl Rubber Insulated
Metal-clad Cables with Grounding Conductor
Nonshielded Single-conductor Power Cable
PART 8 - APPENDICES
Abbreviations and Symbols
Representative Tensile Strength and Elongation of Non-
magnetic Metals
Definitions for Maximum Temperature of Conductors in
Insulated Wire and Cable
Emergency Overload Ratings for Rubber-Insulated Cables
Referenced ICEA Publications and ASTM Standards
Shielding
Recommended Bending Radii for Cables
Ampacities for Three-conductor Mine Power Cables 2001
to 15000 Volts copper and Aluminium
Conductor Identification for Control Cables
Additional Conductor Information
Ampacities for Preassembled Aerial Cables
These standards apply to materials, constructions and testing of rubber-insulated wires and cables which are used for the transmission and distribution of electrical energy for normal conditions of installation and service, either indoors, aerial, underground, or submarine.
DocumentType |
Standard
|
PublisherName |
National Electrical Manufacturers Association
|
Status |
Superseded
|
SupersededBy |
A-A-50304 Base Document:1987 | DYNAMOMETER, ENGINE RUN-IN, 500 HORSEPOWER CAPACITY |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEEE 241 : 1990 | ELECTRIC POWER SYSTEMS IN COMMERCIAL BUILDINGS |
IEEE DRAFT 404 : D13 2006 | EXTRUDED AND LAMINATED DIELECTRIC SHIELDED CABLE JOINTS RATED 2500 V - 500 000 V |
IEEE 902-1998 | IEEE Guide for Maintenance, Operation, and Safety of Industrial and Commercial Power Systems (Yellow Book) |
IEEE 141 : 1993 | IEEE Recommended Practice for Electric Power Distribution for Industrial Plants |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
API 540:1999 | ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
TM 5-811-1 : V19950228 | ARMY TECHNICAL MANUAL - ELECTRICAL POWER SUPPLY AND DISTRIBUTION |
EN 61009-1:2012/A12:2016 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
GGG-E-2814 Base Document:1993 | ETCHERS, ELECTRIC, PORTABLE |
API 540 : 1999 : R2006 | ELECTRICAL INSTALLATIONS IN PETROLEUM PROCESSING PLANTS |
MIL C 38359 : A | CABLE, POWER, ELECTRICAL, AIRPORT LIGHTING, CROSS-LINKED, POLYETHYLENE XLP |
MIL M 29212 : B NOTICE 1 | MIXING PLANT, ASPHALT, DRUM TYPE, PORTABLE, ELECTRIC MOTOR DRIVEN, 120 TONS PER HOUR CAPACITY |
MIL-L-741 Revision D:1984 | LEAD, ELECTRICAL, ARC WELDING |
MIL-C-82403 Base Document:1965 | CABLE, SUBMARINE, POWER, CONTROL AND COMBINATION |
EN 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm² up to 300 mm² (included) |
API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
EN 60947-7-1:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS |
MIL-C-11085 Revision D:1986 | CONVEYOR, BELT; (FLAT, SKID-MOUNTED, ELECTRIC-MOTOR-DRIVEN, 24-INCH-WIDE BELT, 50-FOOT-LONG FRAME; CAPACITY, 25 POUNDS PER FOOT, 75 TONS PER HOUR) |
EN 60998-2-1:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
BS EN 60947-1 : 2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
BS EN 60947-7-1:2009 | Low-voltage switchgear and controlgear Ancillary equipment. Terminal blocks for copper conductors |
BS EN 60998-2-1:2004 | Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units |
CSA C22.2 No. 249 : 1996 : R2011 | STANDARD TESTS FOR DETERMINING COMPATIBILITY OF CABLE-PULLING LUBRICANTS WITH WIRE AND CABLE |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60947-7-1:2009 | Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors |
CAN/CSA-C22.2 NO. 60947-1-13 (R2018) | Low-voltage switchgear and controlgear - Part 1: General rules (Tri-national standard, with UL 60947-1 and NMX-J-515-ANCE) |
IEEE 1019-2013 REDLINE | IEEE Recommended Practice for Specifying Electric Submersible Pump Cable—Polypropylene Insulation |
EN 61008-1:2012/A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
CSA C22.2 No. 249 : 1996 : R2015 | STANDARD TESTS FOR DETERMINING COMPATIBILITY OF CABLE-PULLING LUBRICANTS WITH WIRE AND CABLE |
BS EN 60898-1 : 2003 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION |
BS EN 61009-1 : 2012 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
BS EN 60998-2-3:2004 | Connecting devices for low-voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
BS EN 61008-1 : 2012 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
UNE-EN 61008-1:2013 | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules |
NEMA HP 100:1991(R2010) | High-Temperature Instrumentation and Control Cables |
NASA KSC SPEC E 0019 : 1997 | AC POWER CABLE, GENERAL PURPOSE, MULTICONDUCTOR, 600 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
NASA KSC SPEC E 0017 : 1996 | ELECTRICAL POWER CABLE, INSTALLATION OF, SPECIFICATION FOR |
I.S. EN 60898-1:2003 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002 (MOD)) |
API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
I.S. EN 60947-1:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES |
I.S. EN 60947-7-1:2009 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-1: ANCILLARY EQUIPMENT - TERMINAL BLOCKS FOR COPPER CONDUCTORS |
I.S. EN 60998-2-1:2004 | CONNECTING DEVICES FOR LOW-VOLTAGE CIRCUITS FOR HOUSEHOLD AND SIMILAR PURPOSES - PART 2-1: PARTICULAR REQUIREMENTS FOR CONNECTING DEVICES AS SEPARATE ENTITIES WITH SCREW-TYPE CLAMPING UNITS |
ASTM D 3349 : 2017 : REDLINE | Standard Test Method for Absorption Coefficient of Ethylene Polymer Material Pigmented with Carbon Black |
ASTM B 174 : 2017 : REDLINE | Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors |
ASTM B 29 : 2014 : REDLINE | Standard Specification for Refined Lead |
ASTM B 172 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors |
ASTM B 496 : 2016 : REDLINE | Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors |
ASTM B 246 : 2015 : REDLINE | Standard Specification for Tinned Hard-Drawn and Medium-Hard-Drawn Copper Wire for Electrical Purposes |
ASTM D 257 : 2014 : REDLINE | Standard Test Methods for DC Resistance or Conductance of Insulating Materials |
ASTM E 8 : 2004 | Standard Test Methods for Tension Testing of Metallic Materials |
ASTM B 173 : 2017 : REDLINE | Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors |
ASTM D 471 : 2016-02 | TEST METHOD FOR RUBBER PROPERTY - EFFECT OF LIQUIDS |
ASTM D 746 : 2014 : REDLINE | Standard Test Method for Brittleness Temperature of Plastics and Elastomers by Impact |
ASTM D 1693 : 2015 : REDLINE | Standard Test Method for Environmental Stress-Cracking of Ethylene Plastics |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.