UTEC 93 526 : 2004

Current

Current

The latest, up-to-date edition.

CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH FOR LOCAL AREA TELECOMMUNICATION NETWORKS - GENERIC SPECIFICATION

Published date

12-01-2013

Sorry this product is not available in your region.

AVANT-PROPOS
SECTION 1 - GÉNÉRALITÉS
1 DOMAINE D'APPLICATION
2 NORMES DE RÉFÉRENCES
3 ASSURANCE DE LA QUALITE
SECTION 2 - CONSTRUCTION DU CABLE
4 CONDUCTEURS
   4.1 Nature du conducteur
   4.2 Type de conducteur
   4.3 État de surface du conducteur
5 ENVELOPPE ISOLANTE
   5.1 Nature de l'enveloppe isolante
   5.2 Épaisseur de l'enveloppe isolante
   5.3 Repérage des conducteurs
6 ÉLÉMENT DE CABLAGE
7 MODE DE CABLAGE DES ÉLÉMENTS
8 CODE DES COULEURS
9 QUARTES DE RÉSERVE
10 REMPLISSAGE
   10.1 Matière de remplissage
11 REVETEMENT DE L'AME DU CABLE
12 GAINE
   12.1 Nature de la gaine
        12.1.1 Polyéthylène (Pe)
        12.1.2 Polychlorure de Vinyle (PVC)
        12.1.3 Matériaux de faible corrosivité
        12.1.4 Matériaux sans halogène
        12.1.5 Écran métallique
   12.2 Application de la gaine
        12.2.1 Gaine
        12.2.2 Gaine avec porteur intégré
        12.2.3 Épaisseur de la gaine
13 PROTECTION DU CABLE
14 CABLE EN ÉTAT DE LIVRAISON
   14.1 Diamètre sur gaine
   14.2 Marquage d'identification et marquage métrique
   14.3 Obturation des extrémités
15 LIVRAISON
SECTION 3 - PRESCRIPTIONS MÉCANIQUES
16 CONDUCTEUR
17 ENVELOPPE ISOLANTE
   17.1 Résistance à l'écrasement des isolants polyéthylène
        cellulaire
18 GAINE
   18.1 Résistance à la traction et allongement
   18.2 Adhérence du ruban métallique au polyéthylène de la gaine
19 CABLE EN ÉTAT DE LIVRAISON
   19.1 Intégrité de la gaine extérieure
   19.2 Résistance à la pénétration de l'eau
   19.3 Vérification de la tenue aux enroulements sous tension
        mécanique
SECTION 4 - PRESCRIPTIONS THERMIQUES ET D'ENVIRONNEMENT
20 ENVELOPPE ISOLANTE
21 GAINE
   21.1 Polyéthylène (Pe)
   21.2 Polychlorure de Vinyle (PVC)
   21.3 Matériaux de faible corrosivité
   21.4 Matériaux sans halogène
SECTION 5 - PRESCRIPTIONS ÉLECTRIQUES
22 RÉSISTANCE ÉLECTRIQUE DU CONDUCTEUR
23 DÉSÉQUILIBRE DE RÉSISTANCE
24 RIGIDITÉ DIÉLECTRIQUE
25 RÉSISTANCE D'ISOLEMENT
26 CAPACITÉ MUTUELLE
27 DÉSÉQUILIBRE DE CAPACITÉ
28 CARACTÉRISTIQUE POUR L'UTILISATION EN RÉGIME NUMÉRIQUE
   28.1 Affaiblissement
   28.2 Impédance caractéristique
   28.3 Diaphonie analogique
   28.4 Diaphonie en régime Numérique
29 PROTECTION ELECTROMAGNETIQUE
   29.1 Facteur réducteur
   29.2 Impédance de retour externe
Annexe A Code des couleurs
Annexe B Identification des faisceaux de base et des faisceaux
         composés
Annexe C Caractéristiques complémentaires pour les polyéthylènes
   C.1 Présence d'antioxydant et de stabilisants
        C.1.1 Sur matière de base
        C.1.2 Après vieillissement pour les isolants massifs et
               pour les isolants cellulaires avec peau des câbles
               remplis
Annexe D Exemple de marquage d'Identification
Annexe E Déséquilibre de capacité (pF)

La présente norme définit les câbles à isolation polyoléfine à usage extérieur pour les réseaux locaux. Cette norme est applicable aux câbles à isolation polyoléfine et gaine polyoléfine remplis ou non remplis, avec des conducteurs en cuivre utilisés comme: Câbles pour une installation en conduites, Câbles pour une pose en pleine terre, Câbles avec un porteur intégré pour les installations aériennes, Câbles de branchement.

DevelopmentNote
Indice de classement: C93-526U. (01/2005) Supersedes NFC 93 526. (03/2005)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current
Supersedes

UTEC 93 527-8 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 278 AND 279
XP C93 503 : 2010 XP MULTI-PAIR CABLES USED IN HIGH BIT RATE COMMUNICATION NETWORKS WITH BANDWIDTH UP TO 30 MHZ - DUCT AND BURIED CABLES
UTEC 93 527-11 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 92
UTEC 93 527-1 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 74
UTEC 93 527-2 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 88 AND 89
UTEC 93 527-7 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 75
UTEC 93 527-3 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 98 AND 99
UTEC 90 486 : 2013 TELECOM RISERS (FOR HOME AND HOME OFFICE)
UTEC 93 527-10 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 5-10E
UTEC 93 527-9 : 2005 TELECOMMUNICATIONS LOCAL NETWORKS CABLES WITH POLYOLEFIN INSULATION AND POLYOLEFIN SHEATH - SERIES 92 AND 5-10
XP C93 504 : 2010 XP MULTI-PAIR CABLES USED IN HIGH BIT RATE COMMUNICATION NETWORKS WITH BANDWIDTH UP TO 30 MHZ - INDOOR AND OUTDOOR RISER CABLES

NF EN 50290-2-24 : 2002 AMD 1 2009 COMMUNICATION CABLES - PART 2-24: COMMON DESIGN RULES AND CONSTRUCTION - PE SHEATHING
UTEC 32 063-2 : 2009 RESISTANCE TO UV RADIATION OF SHEATHING MATERIALS OF COMMUNICATION CABLES
NF EN 50289-4-2 : 2002 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-2: ENVIRONMENTAL TEST METHODS - WATER PENETRATION
IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
NF EN 50290-2-28 : 2002 COMMUNICATION CABLES - PART 2-28: COMMON DESIGN RULES AND CONSTRUCTION - FILLING COMPOUNDS FOR FILLED CABLES
NF EN 50289-1-4 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-4: ELECTRICAL TEST METHODS - INSULATION RESISTANCE
NF EN 50289-3-4 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-4: MECHANICAL TEST METHODS - TENSILE STRENGTH, ELONGATION AND SHRINKAGE OF INSULATION AND SHEATH
NF EN 50290-2-23 : 2017 COMMUNICATION CABLES - PART 2-23: COMMON DESIGN RULES AND CONSTRUCTION - POLYETHYLENE INSULATION FOR MULTI-PAIR CABLES USED IN ACCESS TELECOMMUNICATION NETWORKS: OUTDOOR CABLES
NF EN 50290-2-25 : 2017 COMMUNICATION CABLES - PART 2-25: COMMON DESIGN RULES AND CONSTRUCTION - POLYPROPYLENE INSULATION COMPOUNDS
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
NF EN 50289-3-9 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-9: MECHANICAL TEST METHODS - BENDING TESTS
NF EN 50290-2-27 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-27: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT THERMOPLASTIC SHEATHING COMPOUNDS
UTEC 32 063-1 : 2009 CHEMICAL BEHAVIOUR OF SHEATHING AND INSULATION MATERIALS OF COMMUNICATION CABLES
NF EN 50289-1-2 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-2: ELECTRICAL TEST METHOD - DC RESISTANCE
NF EN 50290-2-22 : 2002 AMD 1 2008 COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS
EN 50289-3-2:2001 Communication cables - Specifications for test methods - Part 3-2: Mechanical test methods - Tensile strength and elongation for conductor
NF EN 50290-1-1 : 2002 COMMUNICATION CABLES - PART 1-1: GENERAL
NF EN 50289-1-3 : 2001 COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-3: ELECTRICAL TEST METHOD - DIELECTRIC STRENGTH
NFC 32 062-1 : 1995 ELECTRONIC COMPONENTS - LOW CORROSIVE MATERIALS FOR INSULATION AND SHEATH USED IN COMMUNICATION CABLES WITH PARTICULAR FIRE RELATED PROPERTIES
NF EN 50290-2-1 : 2005 COMMUNICATION CABLES - PART 2-1: COMMON DESIGN RULES AND CONSTRUCTION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.