1 Scope and object
2 Normative references
3 Terms and definitions
4 Characteristics of solid-state relays
4.1 Summary of characteristics
4.2 Type of solid-state relay
4.3 Rated and limiting values for load circuits
4.4 Load category
4.5 Rated and limiting values for control circuits
5 Marking and documentation
5.1 Marking
5.2 Data
5.3 Instructions for installation, operation and maintenance
6 Normal conditions
6.1 Normal service, transport and storage conditions
6.2 Normal mounting conditions
7 Constructional requirements
7.1 Materials
7.2 Clearances and creepage distances
7.3 Heat and fire resistance
7.4 Terminals
8 Performance requirements
8.1 Temperature-rise
8.2 Overload test
8.3 Endurance test
8.4 Insulation tests
8.5 Impact test
8.6 Ball pressure test
8.7 OFF-state leakage current measurement
8.8 ON-state voltage drop measurement
9 Type test
Annex A (normative) - Insulation coordination
Annex B (normative) - Glow-wire test
Annex C (normative) - Quick-connect terminations
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to particular all-or-nothing electrical relays denominated solid-state relays intended for performing electrical operations by single step function changes to the state of electric circuits between the OFF-state and the ON-state and vice versa. It is applicable to solid-state relays with rated voltages up to 750 V and with a.c. output current up to 160 A.
DevelopmentNote |
Indice de classement: C45-254 PR NF EN 62314 May 2005. (05/2005)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Standards | Relationship |
IEC 62314:2006 | Identical |
UNE-EN 62314:2007 | Identical |
EN 62314 : 2006 | Identical |
NBN EN 62314 : 2006 | Identical |
I.S. EN 62314:2006 | Identical |
SN EN 62314 : 2006 | Identical |
BS EN 62314:2006 | Identical |
DIN EN 62314 : 2007 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
NFC 01 444 : 2002 | ELECTROTECHNICAL VOCABULARY - PART 444: ELEMENTARY RELAYS |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61760-1:2006 | Surface mounting technology - Part 1: Standard method for the specification of surface mounting components (SMDs) |
NF EN 60695-11-10 : 2013 | FIRE HAZARD TESTING - PART 11-10: TEST FLAMES - 50 W HORIZONTAL AND VERTICAL FLAME TEST METHODS |
NF EN 61210 : 2011 | CONNECTING DEVICES - FLAT QUICK-CONNECT TERMINATIONS FOR ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS |
NF EN 60068-2-2 : 2007 | ENVIRONMENTAL TESTING - PART 2-2: TESTS - TESTS B: DRY HEAT |
NF EN 60664-3 : 2017 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATING, POTTING OR MOULDING FOR PROTECTION AGAINST POLLUTION |
NF EN 60529 : 92 AMD 2 2014 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) |
NF EN 60112 : 2003 AMD 1 2010 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
NF EN 61760-1 : 2014 | SURFACE MOUNTING TECHNOLOGY - PART 1: STANDARD METHOD FOR THE SPECIFICATION OF SURFACE MOUNTING COMPONENTS (SMDS) |
NF EN 60068-2-1 : 2007 | ENVIRONMENTAL TESTING - PART 2-1: TESTS - TESTS A: COLD |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
NF EN 60999-1 : 2000 | CONNECTING DEVICES - ELECTRICAL COPPER CONDUCTORS - SAFETY REQUIREMENTS FOR SCREW-TYPE AND SCREW LESS-TYPE CLAMPING UNITS - PART 1: GENERAL REQUIREMENTS AND PARTICULAR REQUIREMENTS FOR CLAMPING UNITS FOR CONDUCTORS FROM 0,2 MM[2] TO 35 MM[2] (INCLUDED) |
NF EN 60068 2-14 : 2009 | ENVIRONMENTAL TESTING - PART 2-14: TESTS - TEST N: CHANGE OF TEMPERATURE |
NFC 20 720 : 87 AMD 1 1988 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TEST METHODS - TEST T - SOLDERING |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
NF EN 60695-10-2 : 2014 | FIRE HAZARD TESTING - PART 10-2: ABNORMAL HEAT - BALL PRESSURE TEST METHOD |
NF EN 60068-2-78 : 2013 | ENVIRONMENTAL TESTING - PART 2-78: TESTS - TEST CAB: DAMP HEAT, STEADY STATE |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 60050-444:2002 | International Electrotechnical Vocabulary (IEV) - Part 444: Elementary relays |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
NF EN 60695-2-10 : 2013 | FIRE HAZARD TESTING - PART 2-10: GLOWING/OUT-WIRE BASED TEST METHOD - GLOW-WIRE APPARATUS AND COMMON TEST PROCEDURE |
NFC 01 195 : 99 AMD 1 2001 | ELECTROTECHNICAL VOCABULARY - CHAPTER 195: EARTHING AND PROTECTION AGAINST ELECTRIC SHOCK |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
Access your standards online with a subscription