CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER
12-01-2013
AVANT-PROPOS
1 Données générales
1.1 Domaine d'application
1.2 Références normatives
2 Termes et définitions
3 Informations relatives aux dimensions
3.1 Caractéristiques communes
3.2 Généralités
3.3 Disposition des contacts de tous les types de
connecteurs
3.4 Etanchéité IP65 et IP
3.5 Variante 13 - CEI 60603-7 industrielle - Levier
de verrouillage
3.6 Informations concernant la sortie et le montage
3.7 Généralités
3.8 Informations concernant le montage pour la variante
13, embase
3.9 Bouchon pour embase, variante 13
4 Calibres
4.1 Connecteurs, interface CEI 60603-7
5 Caractéristiques
5.1 Catégorie climatique
5.2 Caractéristiques électriques
5.3 Caractéristiques de transmission
6 Programme d'essai
6.1 Généralités
6.2 Procédures d'essai et méthodes de mesure
6.3 Préconditionnement
6.4 Câblage et montage des échantillons
6.5 Disposition pour l'essai de la résistance de contact
6.6 Disposition pour les essais de contrainte dynamique
(phase d'essai AP2)
6.7 Programme d'essais de base (minimal)
6.8 Programme d'essais complet
La présente partie de la CEI 61076 couvre les boîtiers de protection pour améliorer les connecteurs à 8 voies blindés et non blindés existants utilisant l'interface décrite dans la CEI 60603-7-2, la CEI 60603-7-3, la CEI 60603-7-4, la CEI 60603-7-5 et la CEI 60603-7-7 pour les caractéristiques IP65 et IP67 conformément à la CEI 60529, utilisés dans les environnements industriels.
DevelopmentNote |
Indice de classement: C93-406-3-116. PR NF EN 61076-3-116 May 2007. (05/2007)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Standards | Relationship |
IEC 61076-3-116:2008 | Identical |
EN 61076-3-116 : 2008 | Identical |
IEC 60603-7-1:2011 | Connectors for electronic equipment - Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors |
NF EN 60603-7 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
NF EN 60603-7-4 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
NF EN 61076-1 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 1: GENERIC SPECIFICATION |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60603-7-2:2010 | Connectors for electronic equipment - Part 7-2: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
NF EN 60664-1 : 2007 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 1: PRINCIPLES, REQUIREMENTS AND TESTS |
NF EN 60603-7-7 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
NF EN 60603-7-5 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
NF EN 60603-7-1 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-1: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS |
NF EN 60529 : 92 AMD 2 2014 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) |
NF EN 60603-7-2 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-2: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 100 MHZ |
NFC 01 581 : 82 AMD 1 1999 | ELECTROTECHNICAL VOCABULARY - CHAPTER 581 - ELECTROMECHANICAL COMPONENTS FOR ELECTRONIC EQUIPMENT |
NF EN 60512-1 : 2001 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TEST AND MEASUREMENTS - PART 1: GENERAL |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
IEC 60603-7-3:2010 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmission with frequencies up to 100 MHz |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
NF EN 60068-1 : 2014 | ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE |
NF EN 60068 2-14 : 2009 | ENVIRONMENTAL TESTING - PART 2-14: TESTS - TEST N: CHANGE OF TEMPERATURE |
IEC 60512-1-100:2012 | Connectors for electronic equipment - Tests and measurements - Part 1-100: General - Applicable publications |
NF EN 60512-1-100 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 1-100: GENERAL - APPLICABLE PUBLICATIONS |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 60603-7-5:2010 | Connectors for electronic equipment - Part 7-5: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60603-7-7:2010 | Connectors for electronic equipment - Part 7-7: Detail specification for 8-way, shielded, free and fixed connectors for data transmission with frequencies up to 600 MHz |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
NF EN 60603-7-3 : DEC 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-3: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.