ISO 30011:2010

Current

Current

The latest, up-to-date edition.

Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma mass spectrometry

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

French, English

Published date

24-09-2010

£139.00
Excluding VAT

ISO 30011:2010 specifies a procedure for the use of quadrupole inductively coupled plasma mass spectrometry (ICPMS) for analysing test solutions prepared from samples of airborne particulate matter collected as specified in ISO 152021. Method development, performance checks, and a routine analysis method are specified.

Test solutions for analysis by ISO 30011:2010 are prepared as specified in ISO 152022.

ISO 30011:2010 is applicable to the assessment of workplace exposure to metals and metalloids for comparison with limit values.

DevelopmentNote
Supersedes ISO/DIS 30011. (09/2010)
DocumentType
Standard
Pages
37
PublisherName
International Organization for Standardization
Status
Current

Standards Relationship
BS ISO 30011:2010 Identical
SS-ISO 30011:2021 Identical
NF ISO 30011 : 2010 Identical

UNI CEN ISO/TS 15011-6 : 2012 HEALTH AND SAFETY IN WELDING AND ALLIED PROCESSES - LABORATORY METHOD FOR SAMPLING FUME AND GASES - PART 6: PROCEDURE FOR QUANTITATIVE DETERMINATION OF FUME AND GASES FROM RESISTANCE SPOT WELDING
BS ISO 18158:2016 Workplace air. Terminology
ISO 18158:2016 Workplace air Terminology
ASTM E 1583 : 2017 Standard Practice for Evaluating Laboratories Engaged in Determination of Lead in Paint, Dust, Airborne Particulates, and Soil Taken From and Around Buildings and Related Structures
ISO 15202-2:2012 Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 2: Sample preparation
ISO/TS 15011-6:2012 Health and safety in welding and allied processes — Laboratory method for sampling fume and gases — Part 6: Procedure for quantitative determination of fume and gases from resistance spot welding
PD CEN ISO/TS 15011-6:2012 Health and safety in welding and allied processes. Laboratory method for sampling fume and gases Procedure for quantitative determination of fume from resistance spot welding
15/30269207 DC : 0 BS ISO 18158 - WORKPLACE AIR - TERMINOLOGY
BS ISO 15202-2:2012 Workplace air. Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Sample preparation
S.R. CEN ISO/TS 15011-6:2012 HEALTH AND SAFETY IN WELDING AND ALLIED PROCESSES - LABORATORY METHOD FOR SAMPLING FUME AND GASES - PART 6: PROCEDURE FOR QUANTITATIVE DETERMINATION OF FUME AND GASES FROM RESISTANCE SPOT WELDING (ISO/TS 15011-6:2012)
UNE 81587:2017 Workplace exposure. Determination of metals and metalloids in airborne particles. Atomic Spectrometry method.

ASTM E 1370 : 2014 : REDLINE Standard Guide for Air Sampling Strategies for Worker and Workplace Protection
ISO 8655-5:2002 Piston-operated volumetric apparatus Part 5: Dispensers
ISO 8655-1:2002 Piston-operated volumetric apparatus Part 1: Terminology, general requirements and user recommendations
ISO 3585:1998 Borosilicate glass 3.3 — Properties
ISO 1042:1998 Laboratory glassware — One-mark volumetric flasks
EN 482:2012+A1:2015 Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents
EN 13890:2009 Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods
ISO 15202-1:2012 Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 1: Sampling
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
ISO 3534-2:2006 Statistics — Vocabulary and symbols — Part 2: Applied statistics
ASTM D 7439 : 2014 : REDLINE Standard Test Method for Determination of Elements in Airborne Particulate Matter by Inductively Coupled Plasma–Mass Spectrometry
ISO 9004:2009 Managing for the sustained success of an organization A quality management approach
ISO 8655-2:2002 Piston-operated volumetric apparatus Part 2: Piston pipettes
EN 1540:2011 Workplace exposure - Terminology
ISO 17294-2:2016 Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of selected elements including uranium isotopes
ISO 8655-6:2002 Piston-operated volumetric apparatus Part 6: Gravimetric methods for the determination of measurement error
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
ISO 15202-2:2012 Workplace air Determination of metals and metalloids in airborne particulate matter by inductively coupled plasma atomic emission spectrometry Part 2: Sample preparation

Access your standards online with a subscription