ISO 12219-1:2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Interior air of road vehicles Part 1: Whole vehicle test chamber Specification and method for the determination of volatile organic compounds in cabin interiors
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-08-2021
English, French
10-07-2012
ISO 12219-1:2012 describes and specifies the whole vehicle test chamber, the vapour sampling assembly and the operating conditions for the determination of volatile organic compounds (VOCs), and carbonyl compounds in vehicle cabin air. There are three measurements performed: one (for VOCs and carbonyl compounds) during the simulation of ambient conditions (ambient mode) at standard conditions of 23 C with no air exchange; a second only for the measurement of formaldehyde at elevated temperatures (parking mode); and a third for VOCs and carbonyl compounds simulating driving after the vehicle has been parked in the sun starting at elevated temperatures (driving mode). For the simulation of the mean sun irradiation, a fixed irradiation in the whole vehicle test chamber is employed.
The VOC method is valid for measurement of non-polar and slightly polar VOCs in a concentration range of sub-micrograms per cubic metre up to several milligrams per cubic metre. Using the principles described in this method, some semi-volatile organic compounds (SVOC) can also be analysed. Compatible compounds are those which can be trapped and released from the Tenax TA[1] sorbent tubes described in ISO 160006, which includes VOCs ranging in volatility from n-C6 to n-C16.
The sampling and analysis procedure for formaldehyde and other carbonyl compounds is performed by collecting air on to cartridges coated with 2,4-dinitrophenylhydrazine (DNPH) and subsequent analysis by high performance liquid chromatography (HPLC) with detection by ultraviolet absorption. Formaldehyde and other carbonyl compounds can be determined in the approximate concentration range 1 g/m3 to 1 mg/m3.
The method is valid for passenger cars, as defined in ISO 3833.
ISO 12219-1:2012 describes: a) transport and storage of the test vehicles until the start of the test; b) conditioning for the surroundings of the test vehicle and the test vehicle itself as well as the whole vehicle test chamber; c) conditioning of the test vehicle prior to measurements; d) simulation of ambient air conditions (ambient mode); e) formaldehyde sampling at elevated temperatures (parking mode); f) simulation of driving after the test vehicle has been parked in the sun (driving mode).
Buses, motor caravans, and trucks, in accordance with the descriptions given in ISO 3833, are excluded.
[1] Tenax TA is the trade name of a product supplied by Buchem. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.
DevelopmentNote |
Supersedes ISO/DIS 12219-1. (07/2012)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
International Organization for Standardization
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
DIN ISO 12219-1:2013-12 | Identical |
GOST R ISO 12219-1 : 2014 | Identical |
NEN ISO 12219-1 : 2012 | Identical |
BS ISO 12219-1:2012 | Identical |
NF ISO 12219-1 : 2012 | Identical |
DIN ISO 16000-6:2012-11 | Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA? sorbent, thermal desorption and gas chromatography using MS or MS-FID (ISO 16000-6:2011) |
BS ISO 16000-16:2008 | Indoor air Detection and enumeration of moulds. Sampling by filtration |
BS ISO 16000-29:2014 | Indoor air Test methods for VOC detectors |
DIN ISO 12219-3:2013-12 | Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012) |
ASTM D 8141 : 2017 | Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments |
DIN ISO 16000-3:2013-01 | Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (ISO 16000-3:2011) |
DIN ISO 16000-17:2010-06 | Indoor air - Part 17: Detection and enumeration of moulds - Culture-based method (ISO 16000-17:2008) |
ISO 12219-7:2017 | Interior air of road vehicles Part 7: Odour determination in interior air of road vehicles and test chamber air of trim components by olfactory measurements |
DIN ISO 16000-13:2010-03 | Indoor air - Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Collection on sorbent-backed filters (ISO 16000-13:2008) |
DIN ISO 16000-18:2012-01 | Indoor air - Part 18: Detection and enumeration of moulds - Sampling by impaction (ISO 16000-18:2011 + Cor.1:2011) |
15/30273463 DC : 0 | BS ISO 12219-7 - INTERIOR AIR OF ROAD VEHICLES - PART 7: ODOUR DETERMINATION IN INTERIOR AIR OF ROAD VEHICLES AND TEST CHAMBER AIR OF TRIM COMPONENTS BY OLFACTORY MEASUREMENTS |
BS ISO 16000-17:2008 | Indoor air Detection and enumeration of moulds. Culture-based method |
BS ISO 16000-14:2009 | Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
ISO 16000-13:2008 | Indoor air — Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters |
ISO 16000-17:2008 | Indoor air — Part 17: Detection and enumeration of moulds — Culture-based method |
ISO 16000-16:2008 | Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration |
DIN ISO 16000-29:2015-02 | INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014) |
BS ISO 12219-7:2017 | Interior air of road vehicles Odour determination in interior air of road vehicles and test chamber air of trim components by olfactory measurements |
BS ISO 16000-13:2008 | Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Collection on sorbent-backed filters |
DIN ISO 16000-16:2009-12 | Indoor air - Part 16: Detection and enumeration of moulds - Sampling by filtration (ISO 16000-16:2008) |
DIN ISO 16000-14:2012-03 | Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009) |
ISO 16000-14:2009 | Indoor air — Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry |
ISO 16000-29:2014 | Indoor air — Part 29: Test methods for VOC detectors |
JASO Z 125 : 2009 | GENERAL AND OTHERS - ROAD VEHICLES - INTERIOR - MEASUREMENT METHODS OF DIFFUSED VOLATILE ORGANIC COMPOUNDS (VOC) |
ISO 16000-25:2011 | Indoor air Part 25: Determination of the emission of semi-volatile organic compounds by building products Micro-chamber method |
ISO 16000-5:2007 | Indoor air Part 5: Sampling strategy for volatile organic compounds (VOCs) |
ISO 9060:1990 | Solar energy Specification and classification of instruments for measuring hemispherical solar and direct solar radiation |
ISO 16017-1:2000 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling |
ISO 16000-24:2009 | Indoor air Part 24: Performance test for evaluating the reduction of volatile organic compound (except formaldehyde) concentrations by sorptive building materials |
ISO 16017-2:2003 | Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling |
ISO 3833:1977 | Road vehicles — Types — Terms and definitions |
ISO 16000-9:2006 | Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method |
ISO 16000-3:2011 | Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method |
ISO 16000-10:2006 | Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method |
ISO 16000-11:2006 | Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens |
ISO 16000-6:2011 | Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.