IEC 62439-6:2010
Current
The latest, up-to-date edition.
Industrial communication networks - High availability automation networks - Part 6: Distributed Redundancy Protocol (DRP)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, English - French
26-02-2010
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, abbreviations, acronyms, and
conventions
4 Overview
5 DRP communications
6 DRP class specification
7 DRP attributes
8 DRP services
9 DRP protocol specification
Bibliography
IEC 62439-6:2010 is applicable to high-availability automation networks based on the ISO/IEC 8802-3 (IEEE 802.3) (Ethernet) technology. It specifies a recovery protocol based on a ring topology, designed to react deterministically on a single failure of an inter-switch link or switch in the network. Each switch has equal management role in the network. Double rings are supported. It cancels and replaces IEC 62439 published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to IEC 62439 (2008):
- adding a calculation method for RSTP (rapid spanning tree protocol, IEEE 802.1Q),
- adding two new redundancy protocols: HSR (High-availability Seamless Redundancy) and DRP (Distributed Redundancy Protocol),
- moving former Clauses 1 to 4 (introduction, definitions, general aspects) and the Annexes (taxonomy, availability calculation) to IEC 62439-1, which serves now as a base for the other documents,
- moving Clause 5 (MRP) to IEC 62439-2 with minor editorial changes,
- moving Clause 6 (PRP) was to IEC 62439-3 with minor editorial changes,
- moving Clause 7 (CRP) was to IEC 62439-4 with minor editorial changes, and
- moving Clause 8 (BRP) was to IEC 62439-5 with minor editorial changes,
- adding a method to calculate the maximum recovery time of RSTP in a restricted configuration (ring) to IEC 62439-1 as Clause 8,
- adding specifications of the HSR (High-availability Seamless Redundancy) protocol, which shares the principles of PRP to IEC 62439-3 as Clause 5, and
- introducing the DRP protocol as IEC 62439-6.
This publication is to be read in conjunction with IEC 62439-1:2010.
Committee |
TC 65/SC 65C
|
DevelopmentNote |
Supersedes IEC 62439. To be read in conjunction with IEC 62439-1. (03/2010) A Bilingual edition has been published. (12/2012) Stability Date: 2020. (09/2017)
|
DocumentType |
Standard
|
Pages |
64
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 62439-6 : 2013 | Identical |
NEN EN IEC 62439-6 : 2010 | Identical |
I.S. EN 62439-6:2010 | Identical |
UNE-EN 62439-6:2010 | Identical |
BS EN 62439-6:2010 | Identical |
CEI EN 62439-6 : 2011 | Identical |
EN 62439-6:2010 | Identical |
DIN EN 62439-6:2010-09 | Identical |
PNE-FprEN 62439-6 | Identical |
BS EN 62439-5:2010 | Industrial communication networks. High availability automation networks Beacon redundancy protocol (BRP) |
BS EN 62439-1 : 2010 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS |
EN 61162-460:2015 | Maritime navigation and radiocommunication equipment and systems - Digital interfaces - Part 460: Multiple talkers and multiple listeners - Ethernet interconnection - Safety and security |
14/30297254 DC : 0 | BS EN 62439-X - INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS |
IEC 62439-4:2010 | Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP) |
I.S. EN 62439-5:2010 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP) |
EN 62439-1:2010/A2:2017 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS (IEC 62439-1:2010/A2:2016) |
16/30346333 DC : 0 | BS EN 61162-460 - MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS -DIGITAL INTERFACES - PART 460: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION - SAFETY AND SECURITY |
I.S. EN 62439-1:2010 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 1: GENERAL CONCEPTS AND CALCULATION METHODS |
I.S. EN 61162-460:2015 | MARITIME NAVIGATION AND RADIOCOMMUNICATION EQUIPMENT AND SYSTEMS - DIGITAL INTERFACES - PART 460: MULTIPLE TALKERS AND MULTIPLE LISTENERS - ETHERNET INTERCONNECTION - SAFETY AND SECURITY |
I.S. EN IEC 62439-5:2018 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP) |
IEC 62439-3:2016 | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
EN IEC 62439-5:2018 | Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP) |
EN IEC 62439-3:2018 | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV | Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods |
BS EN 62439-4 : 2010 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 4: CROSS-NETWORK REDUNDANCY PROTOCOL (CRP) |
BS EN 61162-460:2015 | Maritime navigation and radiocommunication equipment and systems. Digital interfaces Multiple talkers and multiple listeners. Ethernet interconnection. Safety and security |
CEI EN 62439-2 : 2011 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 2: MEDIA REDUNDANCY PROTOCOL (MRP) |
CEI EN 62439-3 : 2013 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 3: PARALLEL REDUNDANCY PROTOCOL (PRP) AND HIGH-AVAILABILITY SEAMLESS REDUNDANCY (HSR) |
IEC 62439-5:2016 | Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP) |
BS EN 62439-3:2012 | Industrial communication networks. High availability automation networks Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
I.S. EN 62439-3:2012 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 3: PARALLEL REDUNDANCY PROTOCOL (PRP) AND HIGH-AVAILABILITY SEAMLESS REDUNDANCY (HSR) (IEC 62439-3:2012 (EQV)) |
I.S. EN IEC 62439-3:2018 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 3: PARALLEL REDUNDANCY PROTOCOL (PRP) AND HIGH-AVAILABILITY SEAMLESS REDUNDANCY (HSR) |
CEI EN 62439-5 : 2011 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 5: BEACON REDUNDANCY PROTOCOL (BRP) |
I.S. EN 62439-4:2010 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 4: CROSS-NETWORK REDUNDANCY PROTOCOL (CRP) (IEC 62439-4:2010 (EQV)) |
EN 62439-4:2010/A1:2012 | INDUSTRIAL COMMUNICATION NETWORKS - HIGH AVAILABILITY AUTOMATION NETWORKS - PART 4: CROSS-NETWORK REDUNDANCY PROTOCOL (CRP) (IEC 62439-4:2010/A1:2012) |
IEC 62439-3:2016 RLV | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
IEC 62439-3:2016 | Industrial communication networks - High availability automation networks - Part 3: Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) |
IEC 62439-4:2010 | Industrial communication networks - High availability automation networks - Part 4: Cross-network Redundancy Protocol (CRP) |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
IEEE 802.1Q-2014 | IEEE Standard for Local and metropolitan area networks--Bridges and Bridged Networks |
IEEE 802.1D-2004 | IEEE Standard for Local and metropolitan area networks: Media Access Control (MAC) Bridges |
IEC 62439-5:2016 | Industrial communication networks - High availability automation networks - Part 5: Beacon Redundancy Protocol (BRP) |
IEC 61588:2009 | Precision clock synchronization protocol for networked measurement and control systems |
IEC 62439-1:2010+AMD1:2012+AMD2:2016 CSV | Industrial communication networks - High availability automation networks - Part 1: General concepts and calculation methods |
ISO/IEC TR 8802-1:2001 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 1: Overview of Local Area Network Standards |
IEC 62439-2:2016 | Industrial communication networks - High availability automation networks - Part 2: Media Redundancy Protocol (MRP) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.