IEC 61442:2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
19-10-2023
English - French, English, French, Spanish, Castilian
07-03-2005
FOREWORD
1 Scope
2 Normative references
3 Test installations and conditions
4 AC voltage tests
4.1 Dry test for all accessories
4.2 Wet test for outdoor terminations
4.3 Test in water for stop ends
5 DC voltage tests
5.1 Installation
5.2 Method
6 Impulse voltage tests
6.1 Installation
6.2 Method
6.3 Test at elevated temperature
7 Partial discharge test
7.1 Method
7.2 Test at elevated temperature
8 Tests at elevated temperature
8.1 Installation and connection
8.2 Measurement of temperature
9 Heating cycles voltage test
9.1 Installation
9.2 Test in air
9.3 Test in water
9.4 Immersion test for outdoor terminations
10 Thermal short-circuit test (screen)
10.1 Installation
10.2 Method
11 Thermal short-circuit test (conductor)
11.1 Installation
11.2 Method
12 Dynamic short-circuit test
12.1 Installation
12.2 Method
13 Humidity and salt fog tests
13.1 Apparatus
13.2 Installation
13.3 Method
14 Impact test at ambient temperature
15 Screen resistance measurement
15.1 Installation
15.2 Method
16 Screen leakage current measurement
16.1 Installation
16.2 Method
17 Screen fault current initiation test
17.1 Installation
17.2 Method
18 Operating force test
18.1 Installation
18.2 Method
19 Operating eye test
19.1 Installation
19.2 Method
20 Capacitive test point performance
20.1 Installation
20.2 Test method
Annex A (informative) Determination of the cable conductor
temperature
Annex B (informative) Details of the test chamber and spray
equipment for humidity and salt fog tests
Bibliography
Figures
Specifies the test methods to be used for type testing accessories for power cables with rated voltage from 3,6/6 (7,2) kV up to 18/30 (36) kV. Test methods are specified for accessories for extruded and paper insulated cables according to IEC 60502-2 and IEC 60055-1 respectively. Significant technical changes with respect to the previous edition are as follows: a) a test in water has been added for stop ends; b) the heating cycles voltage test has been revised to clarify testing in air and water; c) the testing conditions for the short-circuit tests have been redefined; d) additional information has been provided for testing separable connectors with a metallic housing; e) tests not required by IEC, i.e. an immersion test for outdoor terminations and an impact test, have been included in order to have a common test method document with CENELEC under the IEC/CLC Dresden agreement.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
61
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 61442 : 2005 | Identical |
NEN EN IEC 61442 : 2005 | Identical |
I.S. EN 61442:2005 | Identical |
VDE 0278-442 : 2006 | Identical |
BS EN 61442:2005 | Identical |
UNE-EN 61442:2005 | Identical |
CEI EN 61442 : 2006 | Identical |
EN 61442:2005 | Identical |
BS EN 61158-5-15:2008 | Identical |
IEEE 386-2016 | IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV |
BS 7888-4.1(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
I.S. EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
I.S. HD 629.1:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3.6/6(7.2) KV UP TO 20.8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
EN 45510-2-9:2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
EN 45510-2-9 : 2008 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-9: ELECTRICAL EQUIPMENT - CABLING SYSTEMS |
I.S. HD 629-2:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS EN 45510-2-9:2008 | Guide for procurement of power station equipment Electrical equipment. Cabling systems |
BS 7888-4.2(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60055-1:1997+AMD1:2005 CSV | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.