FOREWORD
1 General
  1.1 Scope and object
  1.2 Normative references
2 Terms and definitions
  2.1 Basic definitions
  2.2 Characteristics of a flow rate switch
  2.3 Delay times
3 Classification
  3.1 General
  3.2 Classification according to sensing means
  3.3 Classification according to the construction form
  3.4 Classification according to the switching element function
  3.5 Classification according to the type of output
  3.6 Classification according to the method of connection
4 Characteristics
  4.1 Summary of characteristics
  4.2 Operating conditions
  4.3 Rated and limiting values for the flow rate switch
  4.4 Utilization categories for the switching element
5 Product information
  5.1 Nature of information
  5.2 Marking
  5.3 Instruction for installation, operation and maintenance
6 Normal service, mounting and transport conditions
  6.1 Normal service conditions
  6.2 Conditions during transport and storage
  6.3 Mounting
  6.4 Indicating means
7 Constructional and performance requirements
  7.1 Constructional requirements
  7.2 Performance requirements
  7.3 Shock and vibration
8 Tests
  8.1 Kinds of tests
  8.2 Compliance with constructional requirements
  8.3 Performance
  8.4 Verification of set point and delay times
  8.5 Verification of the electromagnetic compatibility
  8.6 Test results and test report

This part of IEC 60947 applies to flow rate switches that sense the rate of flow of a gas, a liquid or a granular solid. These switches change their output state if a pre-set value for the speed of flow is exceeded. These flow rate switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c.

DevelopmentNote
Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
69
PublisherName
International Electrotechnical Committee
Status
Current

IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61558-2-6:2009 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV Low-voltage switchgear and controlgear - Part 1: General rules
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-3-3:2013 RLV Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60947-5-2:2007+AMD1:2012 CSV Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches
IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.