IEC 60695-1-10:2016
Current
The latest, up-to-date edition.
Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian, Russian
18-11-2016
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Fire hazards associated with electrotechnical
products
5 Fundamentals of fire hazard testing
6 Types of fire test
7 Appropriate use of qualitative fire tests
8 Preparation of requirements and test specifications
9 Common ignition sources
10 Reference documents of TC 89
Annex A (informative) - The power output of ignition
sources
Annex B (informative) - Guidance publications and
test methods
Bibliography
IEC 60695-1-10:2016 provides general guidance with respect to fire hazard testing on how to reduce to a tolerable level the risk of fire and the potential effects of fires involving electrotechnical products. It also serves as a signpost standard to the other guidance publications in the IEC 60695 series. It does not give guidance on the use of fire-resistant compartment boundaries or on the use of detection and suppression systems for the mitigation of fire risk. It describes the relationship between fire risk and the potential effects of fire, and provides guidance to IEC product committees on the applicability of qualitative and quantitative fire tests to the fire hazard assessment of electrotechnical products. Details of the calculation of fire risk are not included in the scope of this document. It emphasises the importance of the scenario approach to fire hazard and risk assessment and discusses criteria intended to ensure the development of technically sound hazard-based fire test methods. It discusses the different types of fire tests, in particular the nature of qualitative and quantitative fire tests. It also describes the circumstances under which it is appropriate for IEC product committees to maintain or develop qualitative fire tests. This standard is intended as guidance to IEC committees, and is to be used with respect to their individual applications. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- reference to IEC 60695-1-12;
- modified Introduction and Scope;
- updated normative references;
- updated terms and definitions;
- modified Table 1;
- addition of Table 2;
- new text in Subclauses 5.2, 5.3 and 5.4;
- mandatory text in Clause 8;
- Annex B changed to Annex A, and modified;
- new Annex B concerning common ignition sources.
This publication is to be read in conjunction with IEC 60695-1-11:2014 and IEC 60695-1-12:2015.
Key words: Fire Hazard, Fire Risk, Fire Safety Engineering
Committee |
TC 89
|
DevelopmentNote |
Together with IEC 60695-1-11, supersedes IEC 60695-1-1. (06/2010) To be read in conjunction with IEC 60695-1-11 and IEC 60695-1-12. Stability Date: 2025. (11/2016)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NF EN 60695-1-10 : 2017 | Identical |
NEN EN IEC 60695-1-10 : 2017 | Identical |
PN EN 60695-1-10 : 2017 | Identical |
SN EN 60695-1-10 : 2017 | Identical |
VDE 0471-1-10 : 2017 | Identical |
DIN EN 60695-1-10 : 2017 | Identical |
UNE-EN 60695-1-10:2017 | Identical |
BS EN 60695-1-10:2017 | Identical |
CEI EN 60695-1-10 : 2012 | Identical |
EN 60695-1-10:2017 | Identical |
JIS C 60695-1-10:2020 | Identical |
CEI EN 60695-1-10:2020 | Identical |
SAC GB/T 5169-2 : 2013 | Identical |
07/30169692 DC : 0 | BS EN 60695-2-12 - FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS |
BS EN 60695-1-40:2014 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Insulating liquids |
BS EN 60695-7-3:2011 | Fire hazard testing Toxicity of fire effluent. Use and interpretation of test results |
CEI EN 60695-1-30 : 2010 | FIRE HAZARD TESTING - PART 1-30: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - PRESELECTION TESTING PROCESS - GENERAL GUIDELINES |
UNE-EN 60695-1-20:2016 | Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance |
09/30206172 DC : 0 | BS EN 60695-7-3 ED.1 - FIRE HAZARD TESTING - PART 7-3: TOXICITY OF FIRE EFFLUENT - USE AND INTERPRETATION OF TEST RESULTS |
CEI 89-38 : 2014 | FIRE HAZARD TESTING - PART 11-11: TEST FLAMES - DETERMINATION OF THE CHARACTERISTIC HEAT FLUX FOR IGNITION FROM A NON-CONTACTING FLAME SOURCE |
09/30166429 DC : 0 | BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
I.S. EN 60695-11-20:2015 | FIRE HAZARD TESTING - PART 11-20: TEST FLAMES - 500 W FLAME TEST METHODS |
I.S. EN 60695-2-10:2013 | FIRE HAZARD TESTING - PART 2-10: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE APPARATUS AND COMMON TEST PROCEDURE (IEC 60695-2-10:2013 (EQV)) |
I.S. EN 60695-2-11:2014 | FIRE HAZARD TESTING - PART 2-11: GLOWING/HOTWIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END-PRODUCTS (GWEPT) |
AAMI ES60601-1 : 2005 : INC : AMD 1 : 2012 : R201200 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
AAMI ES60601-1 : 2005 : INC : AMD 2 : 2012 : R201200 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
AAMI ES60601-1 : 2005 : R2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
UNE-EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
IEC 60695-7-1:2010 | Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance |
IEC 60695-1-40:2013 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
EN 60695-7-3 : 2011 | FIRE HAZARD TESTING - PART 7-3: TOXICITY OF FIRE EFFLUENT - USE AND INTERPRETATION OF TEST RESULTS (IEC 60695-7-3:2011) |
EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
EN 60695-1-11:2015 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
EN 60695-8-2:2017 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
EN 60695-1-30:2017 | Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
BS EN 60695-7-1:2010 | Fire hazard testing Toxicity of fire effluent. General guidance |
BS EN 60695-11-10:2013 | Fire hazard testing Test flames. 50 W horizontal and vertical flame test methods |
DD IEC/TS 60695-8-3:2008 | Fire hazard testing Heat release. Heat release of insulating liquids used in electrotechnical products |
07/30169693 DC : 0 | BS EN 60695-11-11 - FIRE HAZARD TESTING - PART 11-11: TEST FLAMES - DETERMINATION OF THE IGNITION CHARACTERISTIC HEAT FLUX FROM A NON-CONTACTING FLAME SOURCE |
12/30273535 DC : 0 | IEC 60695-2-11 ED 2.0 - FIRE HAZARD TESTING - PART 2-11: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END PRODUCTS |
11/30193150 DC : 0 | BS EN 60601-1:2006 AMD.1 - MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
09/30183765 DC : 0 | BS EN 60695-6-1 A1 ED.2 - FIRE HAZARD TESTING - PART 6-1: SOME OBSCURATION - GENERAL GUIDANCE |
BS EN 60695-2-12 : 2010 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS |
CEI EN 60695-2-11 : 2014 | FIRE HAZARD TESTING - PART 2-11: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY TEST METHOD FOR END-PRODUCTS (GWEPT) |
PD IEC/TR 62757:2015 | Fire prevention measures on converters for high-voltage direct current (HVDC) systems, static var compensators (SVC) and flexible ac transmission systems (FACTS) and their valve halls |
BS EN 60695-6-1 : 2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
I.S. EN 60695-10-3:2016 | FIRE HAZARD TESTING - PART 10-3: ABNORMAL HEAT - MOULD STRESS RELIEF DISTORTION TEST |
I.S. EN 60695-11-2:2017 | FIRE HAZARD TESTING - PART 11-2: TEST FLAMES - 1 KW NOMINAL PRE-MIXED FLAME - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
CEI EN 60695-7-1 : 2013 | FIRE HAZARD TESTING - PART 7-1: TOXICITY OF FIRE EFFLUENT - GENERAL GUIDANCE |
I.S. EN 60695-7-3:2011 | FIRE HAZARD TESTING - PART 7-3: TOXICITY OF FIRE EFFLUENT - USE AND INTERPRETATION OF TEST RESULTS (IEC 60695-7-3:2011) |
CEI EN 60695-10-2 : 2015 | FIRE HAZARD TESTING - PART 10-2: ABNORMAL HEAT - BALL PRESSURE TEST METHOD |
I.S. EN 60695-1-11:2015 | FIRE HAZARD TESTING - PART 1-11: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - FIRE HAZARD ASSESSMENT |
EN 60695-6-1:2005/A1:2010 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
IEC TS 60695-1-20:2008 | Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance |
IEC TS 60695-1-14:2017 | Fire hazard testing - Part 1-14: Guidance on the different levels of power and energy related to the probability of ignition and fire in low voltage electrotechnical products |
IEC PAS 62282-6-150:2011 | Fuel cell technologies - Part 6-150: Micro fuel cell power systems - Safety - Water reactive (UN Devision 4.3) compounds in indirect PEM fuel cells |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
AAMI ES60601-1 : 2005 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD) |
IEC 60695-8-1:2016 | Fire hazard testing - Part 8-1: Heat release - General guidance |
PD IEC/TR 62222:2012 | Fire performance of communication cables installed in buildings |
UNE-EN 60695-1-30:2017 | Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines |
07/30169691 DC : 0 | BS EN 60695-2-13 - FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITABILITY (GWIT) TEST METHOD FOR MATERIALS |
14/30287765 DC : 0 | BS EN 60695-1-20/ED 1.0 - FIRE HAZARD TESTING - PART 1-20: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - IGNITABILITY - GENERAL GUIDANCE |
BS EN 60695-1-20:2016 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Ignitability. General guidance |
BS EN 60695-1-11:2015 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products. Fire hazard assessment |
13/30281097 DC : 0 | BS EN 60695-1-11 ED 2.0 - FIRE HAZARD TESTING - PART 1-11: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - FIRE HAZARD ASSESSMENT |
UNE-EN 60695-10-3:2017 | Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test |
I.S. EN 60695-8-2:2017 | FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
12/30230305 DC : 0 | BS EN 60695-10-2 ED 3.0 - FIRE HAZARD TESTING - PART 10-2: ABNORMAL HEAT - BALL PRESSURE TEST |
IEC TR 63054:2017 | Low-voltage switchgear and controlgear - Fire risk analysis and risk reduction measures |
CEI EN 60695-8-1 : 2009 | FIRE HAZARD TESTING - PART 8-1: HEAT RELEASE - GENERAL GUIDANCE |
UNE-EN 60695-7-1:2011 | Fire hazard testing -- Part 7-1: Toxicity of fire effluent - General guidance |
12/30269145 DC : 0 | BS EN 60695-1-40 ED 1.0 - FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
UNE-EN 60695-8-1:2017 | Fire hazard testing - Part 8-1: Heat release - General guidance |
CEI 89-37 : 2014 | FIRE HAZARD TESTING - PART 8-3: HEAT RELEASE - HEAT RELEASE OF INSULATING LIQUIDS USED IN ELECTROTECHNICAL PRODUCTS |
IEC TR 60695-8-2:2008 | Fire hazard testing - Part 8-2: Heat release - Summary and relevance of test methods |
BS EN 60695-10-3:2016 | Fire hazard testing Abnormal heat. Mould stress relief distortion test |
UNE-EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN IEC 62688:2018 | Concentrator photovoltaic (CPV) modules and assemblies - Safety qualification |
I.S. EN 60695-10-2:2014 | FIRE HAZARD TESTING - PART 10-2: ABNORMAL HEAT - BALL PRESSURE TEST METHOD |
I.S. EN 60601-1:2006&A1:2013&AC:2014&A12:2014 | MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
I.S. EN 60695-1-40:2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
I.S. EN 60695-11-10:2013 | FIRE HAZARD TESTING - PART 11-10: TEST FLAMES - 50 W HORIZONTAL AND VERTICAL FLAME TEST METHODS (IEC 60695-11-10:2013 (EQV)) |
IEC TS 60695-8-3:2008 | Fire hazard testing - Part 8-3: Heat release - Heat release of insulating liquids used in electrotechnical products |
CEI 89-29 : 2010 | FIRE HAZARD TESTING - PART 1-20: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - IGNITABILITY - GENERAL GUIDANCE |
NF EN 60695-1-11 : 2016 | FIRE HAZARD TESTING - PART 1-11: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - FIRE HAZARD ASSESSMENT |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60695-1-20:2016 | Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
16/30336629 DC : 0 | BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION |
UNE-EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
DD IEC/PAS 62282-6-150:2011 | Fuel cell technologies Micro fuel cell power systems. Safety. Water reactive (UN Division 4.3) compounds in indirect PEM fuel cells |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 60695-2-11:2014 | Fire hazard testing Glowing/hot-wire based test methods. Glow-wire flammability test method for end-products (GWEPT) |
I.S. EN 60695-2-13:2010 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS |
BS EN 60695-11-20:2015 | Fire hazard testing Test flames. 500 W flame test methods |
I.S. EN 60695-6-1:2005 | FIRE HAZARD TESTING - PART 6-1: SMOKE OBSCURATION - GENERAL GUIDANCE |
PD IEC/TS 60695-1-14:2017 | Fire hazard testing Guidance on the different levels of power and energy related to the probability of ignition and fire in low voltage electrotechnical products |
UNE-EN 60695-2-11:2015 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
UNE-EN 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
I.S. EN 60695-1-20:2016 | FIRE HAZARD TESTING - PART 1-20: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - IGNITABILITY - GENERAL GUIDANCE |
I.S. EN 60695-8-1:2017 | FIRE HAZARD TESTING - PART 8-1: HEAT RELEASE - GENERAL GUIDANCE |
UNE-EN 60695-7-3:2012 | Fire hazard testing - Part 7-3: Toxicity of fire effluent - Use and interpretation of test results |
BS EN 60695-1-30:2017 | Fire hazard testing Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process. General guidelines |
CEI EN 60695-7-3 : 2013 | FIRE HAZARD TESTING - PART 7-3: TOXICITY OF FIRE EFFLUENT - USE AND INTERPRETATION OF TEST RESULTS |
IEC TS 60695-11-11:2016 | Fire hazard testing - Part 11-11: Test flames - Determination of the characteristic heat flux for ignition from a non-contacting flame source |
IEC 60215:2016 | Safety requirements for radio transmitting equipment - General requirements and terminology |
I.S. EN 60695-7-1:2010 | FIRE HAZARD TESTING - PART 7-1: TOXICITY OF FIRE EFFLUENTS - GENERAL GUIDANCE |
IEC 60695-1-30:2017 | Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
BS EN 60601-1 : 2006 | MEDICAL ELECTRICAL EQUIPMENT PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC TS 60695-7-3:2004 | Fire hazard testing - Part 7-3: Toxicity of fire effluent - Use and interpretation of test results |
BS EN 60695-8-2:2017 | Fire hazard testing Heat release. Summary and relevance of test methods |
IEC 60695-1-11:2014 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60695-6-1:2005+AMD1:2010 CSV | Fire hazard testing - Part 6-1: Smoke obscuration - General guidance |
IEC 60695-10-3:2016 | Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC TR 62222:2012 | Fire performance of communication cables installed in buildings |
UNE-EN 60695-11-20:2016 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test methods |
UNE-EN 60695-11-10:2014 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
DD IEC TS 60695-1-20 : DRAFT MAR 2008 | FIRE HAZARD TESTING - PART 1-20: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - IGNITABILITY - GENERAL GUIDANCE |
BS EN 60695-8-1:2017 | Fire hazard testing Heat release. General guidance |
PD IEC/TR 63054:2017 | Low-voltage switchgear and controlgear. Fire risk analysis and risk reduction measures |
IEC 60695-11-2:2017 RLV | Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance |
BS EN 60695-11-2:2017 | Fire hazard testing Test flames. 1 kW pre-mixed flame. Apparatus, confirmatory test arrangement and guidance |
10/30216236 DC : DRAFT JAN 2010 | BS EN 60695-11-4 - FIRE HAZARD TESTING - PART 11-4: TEST FLAMES - 50 W FLAME - APPARATUS AND CONFIRMATIONAL TEST METHODS |
BS EN 60695-2-13 : 2010 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS |
10/30198657 DC : 0 | BS EN 60695-7-1 - FIRE HAZARD TESTING - PART 7-1: TOXICITY OF FIRE EFFLUENT - GENERAL GUIDANCE |
BS 8492:2009 | Telecommunications equipment and telecommunications cabling. Code of practice for fire performance and protection |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
UNE-EN 60695-2-13:2011 | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods - Glow-wire ignition temperature (GWIT) test method for materials |
17/30357883 DC : 0 | BS IEC 60695-2-14 ED.1.0 - FIRE HAZARD TESTING - PART 2-14: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE TEST METHOD FOR END PRODUCTS (GWITEP) |
BS EN 60695-2-10:2013 | Fire hazard testing Glowing/hot-wire based test methods. Glow-wire apparatus and common test procedure |
UNE-EN 60695-1-11:2016 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
10/30216139 DC : 0 | BS EN 60695-11-3 - FIRE HAZARD TESTING - PART 11-3: TEST FLAMES - 500 W FLAMES - APPARATUS AND CONFIRMATIONAL TEST METHODS |
CEI EN 60695-8-2 : 2ED 2017 | FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
07/30169687 DC : 0 | BS EN 60695-1-11 - FIRE HAZARD TESTING - PART 1-11: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - FIRE HAZARD ASSESSMENT |
IEC 60695-1-12:2015 | Fire hazard testing - Part 1-12: Guidance for assessing the fire hazard of electrotechnical products - Fire safety engineering |
I.S. EN 60695-2-12:2010 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS |
CEI EN 60695-1-40 : 2014 | FIRE HAZARD TESTING - PART 1-40: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - INSULATING LIQUIDS |
BS EN 60695-10-2:2014 | Fire hazard testing Abnormal heat. Ball pressure test method |
I.S. EN IEC 62688:2018 | CONCENTRATOR PHOTOVOLTAIC (CPV) MODULES AND ASSEMBLIES - SAFETY QUALIFICATION |
UNE-EN 60695-2-12:2011 | Fire hazard testing -- Part 2-12: Glowing/hot-wire based test methods - Glow-wire flammability index (GWFI) test method for materials |
I.S. EN 60695-1-30:2017 | FIRE HAZARD TESTING - PART 1-30: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - PRESELECTION TESTING PROCESS - GENERAL GUIDELINES |
13/30277762 DC : 0 | BS EN 60695-8-2 IEC 60695-8-2 ED 1.0 - FIRE HAZARD TESTING - PART 8-2: HEAT RELEASE - SUMMARY AND RELEVANCE OF TEST METHODS |
PD IEC/TR 60695-8-2:2008 | Fire hazard testing Heat release. Summary and relevance of test methods |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
EN 60695-7-1:2010 | Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
EN 60695-1-40:2014 | Fire hazard testing - Part 1-40: Guidance for assessing the fire hazard of electrotechnical products - Insulating liquids |
IEC 60695-11-2:2017 | Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance |
EN 60695-1-20:2016 | Fire hazard testing - Part 1-20: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - General guidance |
EN 60695-8-1:2017 | Fire hazard testing - Part 8-1: Heat release - General guidance |
EN 60695-11-2:2017 | Fire hazard testing - Part 11-2: Test flames - 1 kW nominal pre-mixed flame - Apparatus, confirmatory test arrangement and guidance |
EN 60695-10-3:2016 | Fire hazard testing - Part 10-3: Abnormal heat - Mould stress relief distortion test |
CEI EN IEC 60695-2-11:2023 | Fire hazard testing Part 2-11: Glowing-hot-wire based test methods - Glow-wire flammability test method for end products (GWEPT) |
ISO/TR 9122-1:1989 | Toxicity testing of fire effluents Part 1: General |
IEC 60695-6-2:2011 | Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
IEC 60695-1-1:1999 | Fire hazard testing - Part 1-1: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
ISO 5659-2:2017 | Plastics — Smoke generation — Part 2: Determination of optical density by a single-chamber test |
ISO 5660-2:2002 | Reaction-to-fire tests Heat release, smoke production and mass loss rate Part 2: Smoke production rate (dynamic measurement) |
EN 60695-1-10:2017 | Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
EN ISO 5659-2:2017 | Plastics - Smoke generation - Part 2: Determination of optical density by a single-chamber test (ISO 5659-2:2017) |
ISO 13943:2017 | Fire safety — Vocabulary |
CEI 89-26 : 2006 | PROVE RELATIVE AI RISCHI DI INCENDIO - PARTE 6-2: OPACITA DEI FUMI - ELENCO E SUGGERIMENTI PER L'UTILIZZO DEI METODI DI PROVA |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN 60695-4:2012 | FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012) |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
EN ISO 13943:2017 | Fire safety - Vocabulary (ISO 13943:2017) |
EN 60695-1-11:2015 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
EN 60695-6-2:2011 | FIRE HAZARD TESTING - PART 6-2: SMOKE OBSCURATION - SUMMARY AND RELEVANCE OF TEST METHODS (IEC 60695-6-2:2011) |
ISO 19706:2011 | Guidelines for assessing the fire threat to people |
IEC 60695-1-11:2014 | Fire hazard testing - Part 1-11: Guidance for assessing the fire hazard of electrotechnical products - Fire hazard assessment |
ASTM E 1354 : 2017 : REDLINE | Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter |
EN 60695-1-1:2000 | Fire hazard testing - Part 1-1: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.