![header thumbnail](/images/img-default-logo.png)
ENV 1995-1-2 : DRAFT 94
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
![header thumbnail](/images/img-default-logo.png)
EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-2: GENERAL RULES - STRUCTURAL FIRE DESIGN
01-11-2004
12-01-2013
Foreword
1 General
1.1 Scope
1.2 Normative References
1.3 Definitions
1.4 Symbols
1.5 Units
2 Basic principles
2.1 Performance requirements
2.2 Actions
2.3 Design values of material properties
2.4 Basic design procedure
2.5 Assessment methods
2.5.1 General
2.5.2 Global structural analysis
2.5.3 Analysis of parts of the structure
2.5.4 Member analysis
3 Materials
3.1 Charring depths
3.2 Fire protective cladding
3.3 Adhesives
4 Structural fire design
4.1 Effective cross-section method
4.2 Reduced strength and stiffness method
4.3 General calculation methods
4.4 Special rules
4.4.1 General
4.4.2 Beams
4.4.3 Columns
4.4.4 Mechanically jointed components
4.4.5 Bracings
4.4.6 Floors and walls
4.5 Joints
4.5.1 General
4.5.2 Unprotected joints with side members of wood
4.5.3 Unprotected joints with external steel plates
4.5.4 Protected joints
Annex A (Normative) Reduced strength and stiffness method
for standard fire exposure
Annex B (Normative) Supplementary rules for joints with
unprotected fasteners
B.1 Joints with unprotected nails
B.2 Joints with unprotected bolts
B.3 Joints with unprotected dowels
B.4 Connectors
B.5 Joints with steel plates
Annex C (Normative) Walls and floors
C.1 Scope
C.2 Design procedure
C.2.1 General
C.2.2 Load bearing constructions
C.2.3 Separating members
C.3 Failure times
C.3.1 Wood and wood-based panels
C.3.2 Non-combustible panels and insulating
layers
C.4 Minimum dimensions
C.4.1 Minimum dimensions
C.4.2 Detailing of panel connections
C.4.3 Connections to adjoining floors and walls
Annex D (Informative) Parametric Fire Exposure
D.1 General
D.2 Charring rates and charring depths
D.3 Load bearing capacity of members in edgewise
bending
Annex E (Informative) Thermal properties
Deals with the design of timber structures for the accidental situation of fire exposure.
Committee |
TC 250
|
DevelopmentNote |
To be read in conjunction with ENV 1995-1-1 and ENV 1991-2-2. (07/2004)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
Standards | Relationship |
I.S. ENV 1995-1-2:1994 | Identical |
UNI ENV 1995-1-2 : 1996 | Identical |
DIN V ENV 1995-1-2:1997-05 | Identical |
NEN NVN ENV 1995-1-2 : 1995 | Identical |
DIN-FACHBERICHT 95 : 2000 | Corresponds |
DD ENV 1995-1.2 : DRAFT JAN 2000 | Identical |
NBN ENV 1995 1-2 : 1995 | Identical |
UNE-ENV 1995-1-2:1999 | Identical |
CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 2: Other funicular railways and other installations |
CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons - Prevention and fight against fire - Part 1: Funicular railways in tunnels |
13/30277104 DC : 0 | BS EN 14389-1 - ROAD TRAFFIC NOISE REDUCING DEVICES - PROCEDURES FOR ASSESSING LONG TERM PERFORMANCE - PART 1: ACOUSTICAL CHARACTERISTICS |
PREN 14389-2 : DRAFT 2013 | ROAD TRAFFIC NOISE REDUCING DEVICES - PROCEDURES FOR ASSESSING LONG TERM PERFORMANCE - PART 2: NON-ACOUSTICAL CHARACTERISTICS |
00/106850 DC : DRAFT OCT 2000 | PREN 13914-1 - THE DESIGN, PREPARATION AND APPLICATION OF EXTERNAL RENDERING AND INTERNAL PLASTERING - EXTERNAL RENDERING |
PREN 14389-1 : DRAFT 2013 | ROAD TRAFFIC NOISE REDUCING DEVICES - PROCEDURES FOR ASSESSING LONG TERM PERFORMANCE - PART 1: ACOUSTICAL CHARACTERISTICS |
PD CEN/TR 14819-2:2005 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Other funicular railways and other installations |
02/103010 DC : DRAFT APR 2002 | PREN 13914-2 - DESIGN, PREPARATION AND APPLICATION OF EXTERNAL RENDERING AND INTERNAL PLASTERING - PART 2: INTERNAL PLASTERING |
I.S. CEN TR 14819-1:2004 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 1: FUNICULAR RAILWAYS IN TUNNELS |
DD ENV 13381-2:2002 | Test methods for determining the contribution to the fire resistance of structural members Vertical protective membranes |
I.S. CEN TR 14819-2:2006 | SAFETY RECOMMENDATIONS FOR CABLEWAY INSTALLATIONS DESIGNED TO CARRY PERSONS - PREVENTION AND FIGHT AGAINST FIRE - PART 2: OTHER FUNICULAR RAILWAYS AND OTHER INSTALLATIONS |
ENV 13381-2:2002 | Test methods for determining the contribution to the fire resistance of stuctural members - Part 2: Vertical protective membranes |
02/102266 DC : DRAFT MAR 2002 | PREN 14389-2 - ROAD TRAFFIC NOISE REDUCING DEVICES - PROCEDURES FOR ASSESSING LONG TERM PERFORMANCE - PART 2: NON-ACOUSTICAL CHARACTERISTICS |
PD ISO/TR 12471:2004 | Computational structural fire design. Review of calculation models, fire tests for determining input material data and needs for further development |
13/30277107 DC : 0 | BS EN 14389-2 - ROAD TRAFFIC NOISE REDUCING DEVICES - PROCEDURES FOR ASSESSING LONG TERM PERFORMANCE - PART 2: NON-ACOUSTICAL CHARACTERISTICS |
DD ENV 13381-7:2002 | Test methods for determining the contribution to the fire resistance of structural members Applied protection to timber members |
ISO/TR 12471:2004 | Computational structural fire design Review of calculation models, fire tests for determining input material data and needs for further development |
I.S. ENV 13381-7:2002 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 7: APPLIED PROTECTION TO TIMBER MEMBERS |
I.S. ENV 13381-2:2002 | TEST METHODS FOR DETERMINING THE CONTRIBUTION TO THE FIRE RESISTANCE OF STRUCTURAL MEMBERS - PART 2: VERTICAL PROTECTIVE MEMBRANES |
03/310921 DC : 0 | EN 14732-1 - TIMBER STRUCTURES - PREFABRICATED WALL, FLOOR AND ROOF ELEMENTS - PART 1: PRODUCT REQUIREMENTS |
PD CEN/TR 14819-1:2004 | Safety recommendations for cableway installations designed to carry persons. Prevention and fight against fire Funicular railways in tunnels |
05/30134009 DC : DRAFT MAY 2005 | EN 15254-1 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 1: GENERAL |
ENV 13381-7:2002 | Test methods for determining the contribution to the fire resistance of structural members - Part 7: Applied protection to timber members |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.