EN 60318-4:2010
Current
The latest, up-to-date edition.

Electroacoustics - Simulators of human head and ear - Part 4: Occluded-ear simulator for the measurement of earphones coupled to the ear by means of ear inserts
07-05-2010
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Construction
5 Calibration
6 Coupling of earphones and hearing aids to the
occluded-ear simulator
7 Maximum permitted expanded uncertainty of measurements
Annex A (informative) - Example of one specific design of
occluded-ear simulator
Annex B (informative) - Principle of calibration for the
occluded-ear simulator
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
IEC 60318-4:2010 describes an occluded-ear simulator intended for the measurement of insert earphones in the frequency range from 100 Hz to 10 000 Hz. It is suitable for air conduction hearing aids and earphones, coupled to the ear by means of ear inserts e.g. ear moulds or similar devices. The occluded-ear simulator is also suitable as the basis for an extension intended to simulate the complete ear canal and the outer ear (for instance in head simulators). The occluded-ear simulator simulates the acoustic transfer impedance for the occluded normal adult human ear. However, it does not simulate the leakage between an earmould and a human ear canal; therefore, the results obtained with the occluded-ear simulator may deviate from the performance of an insert earphone on a real ear, especially at low frequencies. Moreover, large performance variations among individual ears will occur which should be considered when using the ear simulator. Above 10 kHz the device does not simulate a human ear, but can be used as an acoustic coupler at additional frequencies up to 16 kHz. Below 100 Hz, the device has not been verified to simulate a human ear, but can be used as an acoustic coupler at additional frequencies down to 20 Hz. IEC 60318-4:2010 cancels and replaces IEC 60711, published in 1981 and constitutes a technical revision. The main changes with respect to the previous edition are listed below: - extension of the usable frequency range to 100 Hz - 16 000 Hz; - addition of values of maximum permitted expanded uncertainties to all tolerances.
Committee |
CLC/SR 29
|
DevelopmentNote |
Supersedes HD 443. (05/2010)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PN EN 60318-4 : 2011 | Identical |
BS EN 60318-4:2010 | Identical |
DIN EN 60318-4:2010-12 | Identical |
UNE-EN 60318-4:2011 | Identical |
NEN EN IEC 60318-4 : 2010 | Identical |
NF EN 60318-4 : 2011 | Identical |
IEC 60318-4:2010 | Identical |
I.S. EN 60318-4:2010 | Identical |
CEI EN 60318-4 : 2011 | Identical |
NBN EN 60318-4 : 2010 | Identical |
UNE-EN 71-1:2015 | Safety of toys - Part 1: Mechanical and physical properties |
UNE-EN 60645-6:2010 | Electroacoustics - Audiometric equipment -- Part 6: Instruments for the measurement of otoacoustic emissions |
BS EN 60118-0:2015 | Electroacoustics. Hearing aids Measurement of the performance characteristics of hearing aids |
EN 60118-15:2012 | Electroacoustics - Hearing aids - Part 15: Methods for characterising signal processing in hearing aids with a speech-like signal |
EN 61669:2016 | Electroacoustics - Measurement of real-ear acoustical performance characteristics of hearing aids |
BS EN 60645-6:2010 | Electroacoustics. Audiometric equipment Instruments for the measurement of otoacoustic emissions |
I.S. EN 60118-15:2012 | ELECTROACOUSTICS - HEARING AIDS - PART 15: METHODS FOR CHARACTERISING SIGNAL PROCESSING IN HEARING AIDS WITH A SPEECH-LIKE SIGNAL (IEC 60118-15:2012 (EQV)) |
CEI EN 60118-13 : 2012 | ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
I.S. EN 60645-6:2010 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS |
EN 60118-13:2011 | Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
BS EN 60118-15:2012 | Electroacoustics. Hearing aids Methods for characterising signal processing in hearing aids with a speech-like signal |
BS EN 50332-1:2013 | Sound system equipment: Headphones and earphones associated with personal music players. Maximum sound pressure level measurement methodology General method for \'one package equipment\' |
14/30301841 DC : 0 | BS EN 71-1 - SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
13/30281662 DC : 0 | BS EN 50332-1 - SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT" |
I.S. EN 50332-1:2013 | SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PERSONAL MUSIC PLAYERS - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY - PART 1: GENERAL METHOD FOR ONE PACKAGE EQUIPMENT |
PREN 50332-1 : DRAFT 2013 | SOUND SYSTEM EQUIPMENT: HEADPHONES AND EARPHONES ASSOCIATED WITH PORTABLE AUDIO EQUIPMENT - MAXIMUM SOUND PRESSURE LEVEL MEASUREMENT METHODOLOGY AND LIMIT CONSIDERATIONS - PART 1: GENERAL METHOD FOR "ONE PACKAGE EQUIPMENT" |
EN 71-1:2014 | Safety of toys - Part 1: Mechanical and physical properties |
PREN 71-1 : DRAFT 2014 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
UNE-EN 60118-13:2012 | Electroacoustics - Hearing aids - Part 13: Electromagnetic compatibility (EMC) |
DIN EN 71-1:2015-02 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
I.S. EN 60118-13:2011 | ELECTROACOUSTICS - HEARING AIDS - PART 13: ELECTROMAGNETIC COMPATIBILITY (EMC) |
CEI EN 60645-6 : 2013 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 6: INSTRUMENTS FOR THE MEASUREMENT OF OTOACOUSTIC EMISSIONS |
CEI EN 60118-15 : 2014 | ELECTROACOUSTICS - HEARING AIDS - PART 15: METHODS FOR CHARACTERISING SIGNAL PROCESSING IN HEARING AIDS WITH A SPEECH-LIKE SIGNAL |
16/30348450 DC : 0 | BS EN 13819-3 - HEARING PROTECTORS - TESTING - PART 3: SUPPLEMENTARY ACOUSTIC TEST METHOD |
I.S. EN 71-1:2014 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
BS EN 71-1 : 2014 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
BS EN 60118-13:2011 | Electroacoustics. Hearing aids Electromagnetic compatibility (EMC) |
UNI EN 71-1 : 2015 | SAFETY OF TOYS - PART 1: MECHANICAL AND PHYSICAL PROPERTIES |
UNE-EN 60118-15:2012 | Electroacoustics - Hearing aids - Part 15: Methods for characterising signal processing in hearing aids with a speech-like signal |
I.S. EN 61669:2016 | ELECTROACOUSTICS - MEASUREMENT OF REAL-EAR ACOUSTICAL PERFORMANCE CHARACTERISTICS OF HEARING AIDS |
EN 50332-1:2013 | Sound system equipment: Headphones and earphones associated with personal music players - Maximum sound pressure level measurement methodology - Part 1: General method for "one package equipment" |
EN 60118-0:2015 | Electroacoustics - Hearing aids - Part 0: Measurement of the performance characteristics of hearing aids |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
EN 60645-6:2010 | Electroacoustics - Audiometric equipment - Part 6: Instruments for the measurement of otoacoustic emissions |
ANSI/ASA S3.7 : 2016 | METHOD FOR MEASUREMENT AND CALIBRATION OF EARPHONES |
EN 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
IEC 61094-4:1995 | Measurement microphones - Part 4: Specifications for working standard microphones |
EN ISO 389-2:1996 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones (ISO 389-2:1994) |
ISO 389-5:2006 | Acoustics Reference zero for the calibration of audiometric equipment Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz |
EN ISO 389-5:2006 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006) |
EN ISO 389-6:2007 | Acoustics - Reference zero for the calibration of audiometric equipment - Part 6: Reference threshold of hearing for test signals of short duration (ISO 389-6:2007) |
ISO 389-6:2007 | Acoustics Reference zero for the calibration of audiometric equipment Part 6: Reference threshold of hearing for test signals of short duration |
ISO 389-2:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 2: Reference equivalent threshold sound pressure levels for pure tones and insert earphones |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.