EN 50464-2-3:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-3: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 2 for use on distribution transformers meeting the requirements of EN 50464-2-1
01-03-2018
20-04-2007
1 Scope
1.1 High-voltage side
1.2 Low-voltage side
2 Normative references
3 Definitions
4 High-voltage connections
5 Low-voltage connections
6 Design
7 Test
Cable boxes described in this European Standard correspond to cable boxes Type 2 in EN 50464-2-1 and are suitable for assembly on the cover of oil-immersed distribution transformers meeting the requirements of EN 50464-2-1. Cable boxes are air-filled, metal- or non-metal enclosed, for high- and/or low-voltage connections in the following variations: 1.1High-voltage side a)Connection directly to bushings; b)Connection via busbar system. 1.2Low-voltage side a)Connection directly to bushings (maximum of four connectors per bushing); b)Connection via busbar system.
Committee |
CLC/TC 14
|
DevelopmentNote |
Supersedes HD 428.2.3. (04/2007)
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 50464-2-3 : 2007 | Identical |
NBN EN 50464-2-3 : 2007 | Identical |
NEN EN 50464-2-3 : 2007 | Identical |
I.S. EN 50464-2-3:2007 | Identical |
PN EN 50464-2-3 : 2010 | Identical |
SN EN 50464-2-3 : 2007 | Identical |
VDE 0532-222-3 : 2007 | Identical |
DIN EN 50464-2-3 : 2007 | Identical |
BS EN 50464-2-3:2007 | Identical |
UNE-EN 50464-2-3:2010 | Identical |
CEI EN 50464-2-3 : 2007 | Identical |
UNE-EN 50464-2-3:2007 | Identical |
EN 50464-2-2:2007 | Three-phase oil-immersed distribution transformers 50 Hz, from 50 kVA to 2 500 kVA with highest voltage for equipment not exceeding 36 kV - Part 2-2: Distribution transformers with cable boxes on the high-voltage and/or low-voltage side - Cable boxes type 1 for use on distribution transformers meeting the requirements of EN 50464-2-1 |
EN 50386:2010/A1:2013 | BUSHINGS UP TO 1 KV AND FROM 250 A TO 5 KA, FOR LIQUID FILLED TRANSFORMERS |
EN 50180:2010 | Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.