Foreword
1 Scope
2 Normative references
3 Terms and definitions, abbreviations and symbols
  3.1 Terms and definitions
  3.2 Abbreviations
  3.3 Symbols
4 Requirements
  4.1 Moisture penetration index
  4.2 Edge seal strength
  4.3 Gas leakage rate
5 Method of test
  5.1 Principle
  5.2 Climate conditions in cabinet
  5.3 Number, description and selection of the test
      specimens
  5.4 Procedure
6 Methods of measurement
  6.1 Measurement of dew point temperature
  6.2 Measurement of moisture content
      6.2.1 General
      6.2.2 Moisture content of desiccant in bulk
      6.2.3 Moisture content of desiccant incorporated
            in organic spacer
      6.2.4 Moisture content in insulating glass units
            without desiccant
7 Test report
Annex A (normative) - Reference method for dew point
        temperature measurement
    A.1 General
    A.2 Apparatus and materials
    A.3 Procedure
Annex B (normative) - Moisture content measurement
        according to the 950 degree C drying method
    B.1 Applicability
    B.2 Apparatus, materials and preparatory work
    B.3 Initial and final moisture content
    B.4 Standard moisture adsorption capacity
Annex C (normative) - Moisture content measurement
        according to the Karl Fischer method
    C.1 Applicability
    C.2 Apparatus, materials and preparatory work
    C.3 Initial and final moisture content
    C.4 Standard moisture adsorption capacity
Annex D (normative) - Establishing the standard moisture
        adsorption capacity of desiccants
    D.1 General
    D.2 Appropriate information
    D.3 Generally accepted values for desiccant in bulk
    D.4 Desiccant manufacturing
Bibliography

This draft European Standard is the product standard fo insulating glass units, which defines insulating glass units, and ensures by means of an adequate evaluation of conformity to this standard that: - energy savings are made because the U-value and solar factor do not change significantly; - health because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.

Committee
CEN/TC 129
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

PREN 13830 : DRAFT 2013 CURTAIN WALLING - PRODUCT STANDARD
BS EN 1279-1:2004 Glass in building. Insulating glass units Generalities, dimensional tolerances and rules for the system description
UNI EN 1279-5 : 2010 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
BS EN 357:2004 Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance
EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
DIN EN 13830:2015-07 CURTAIN WALLING - PRODUCT STANDARD
BS EN 50583-1:2016 Photovoltaics in buildings BIPV modules
13/30281348 DC : 0 BS EN 13830 - CURTAIN WALLING - PRODUCT STANDARD
I.S. EN 1279-1:2004 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
I.S. EN 1279-3:2002 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 3: LONG TERM TEST METHOD AND REQUIREMENTS FOR GAS LEAKAGE RATE AND FOR GAS CONCENTRATION TOLERANCES
DIN EN 1279-5:2015-08 (Draft) GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
I.S. EN 13830:2015 CURTAIN WALLING - PRODUCT STANDARD
I.S. EN 1096-3:2012 GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS
I.S. EN 357:2004 GLASS IN BUILDING - FIRE RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE
EN 1279-5:2005+A2:2010 Glass in building - Insulating glass units - Part 5: Evaluation of conformity
12/30266506 DC : 0 BS EN 50583 - PHOTOVOLTAICS IN BUILDINGS
NF EN 1279-5 : 2005 + A2 2010 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
I.S. EN 1279-5:2005 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
DIN EN 1096-3:2012-04 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
UNE-EN 13830:2016 Curtain walling - Product standard
UNE-EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
EN 13830:2015 Curtain walling - Product standard
UNI EN 1096-3 : 2012 GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS
03/100996 DC : DRAFT MAR 2003 PREN 13022-1 - GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING SYSTEMS - SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING
PREN 50583 : DRAFT 2012 PHOTOVOLTAICS IN BUILDINGS
I.S. EN 50583-1:2016 PHOTOVOLTAICS IN BUILDINGS - PART 1: BIPV MODULES
BS EN 13830:2015 Curtain walling. Product standard
EN 357:2004 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance
UNE-EN 50583-1:2016 Photovoltaics in buildings - Part 1: BIPV modules
BS EN 1279-3:2002 Glass in building. Insulating glass units Long term test method and requirements for gas leakage rate and for gas concentration tolerances
08/30172148 DC : DRAFT MAY 2008 BS ISO 28278-1 - GLASS IN BUILDING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING - PART 1: SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING
BS EN 1279-5 : 2005 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
DIN EN 1279-1:2015-08 (Draft) GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
BS EN 1096-3:2012 Glass in building. Coated glass Requirements and test methods for class C and D coatings
EN 50583-1:2016 Photovoltaics in buildings - Part 1: BIPV modules
DIN EN 1279-3:2003-05 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 3: LONG TERM TEST METHOD AND REQUIREMENTS FOR GAS LEAKAGE RATE AND FOR GAS CONCENTRATION TOLERANCES
DIN EN 357:2005-02 GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE
UNE-EN 1279-5:2006 Glass in building - Insulating glass units - Part 5: Evaluation of conformity

PREN 1279-1 : DRAFT 95 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES AND DIMENSIONAL TOLERANCES
EN 1279-6:2002 Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
ISO 9001:2015 Quality management systems — Requirements
EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
ISO 760:1978 Determination of water Karl Fischer method (General method)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.