EN 12412-2:2003
Current
The latest, up-to-date edition.
Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames
16-07-2003
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols, units and subscripts
4 Principle
5 Requirements for test specimen and apparatus
5.1 General
5.2 Surround panels
5.3 Specimen requirements and location
5.3.1 Complete frames for windows and doors
5.3.2 Frame and sash, transom or mullion profile sections
5.4 Calibration panels
5.5 Temperature measurement and baffle positions
6 Test procedure
6.1 General
6.2 Calibration measurements
6.2.1 General
6.2.2 Total surface resistance
6.2.3 Surface resistances and surface coefficients of heat
transfer
6.2.4 Surround panel and edge effects
6.3 Measurement procedure for test specimens
7 Test report
Annex A (normative) Determination of environmental temperature
A.1 General
A.2 Environmental temperature
A.3 Mean radiant temperature
A.4 Convective surface heat transfer coefficient
Annex B (normative) Linear thermal transmittance of the
edge zone
Annex C (informative) Example of calibration test and
measurement of frame specimen
C.1 Calibration test with panel size 1,23 m x 1,48 m
C.2 Frame specimen measurement
This European Standard specifies a method, based on EN ISO 8990 and EN ISO 12567-1, to measure the thermal transmittance of frame and sash components of windows and doors, including mullions and transoms.The thermal bridging effect of window or door components (handles, hinges, closing devices, etc.) is included.The test procedure is designed to take into account the whole developed area of the frame or sash surface, but excludes the influence of the thermal bridge introduced through the spacer in sealed glazing units.Edge effects occurring outside of the perimeter of the specimen are excluded. Furthermore, energy transfer due to solar radiation is not taken into account, and air leakage is excluded.The measurements are performed under defined conditions to facilitate the comparison of measured values.Information on the design of the calibration transfer standard is given in EN ISO 12567-1.
Committee |
CEN/TC 89
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
PN EN 12412-2 : 2005 | Identical |
NF EN 12412-2 : 2004 | Identical |
I.S. EN 12412-2:2003 | Identical |
UNE-EN 12412-2:2005 | Identical |
NEN EN 12412-2 : 2003 | Identical |
NBN EN 12412-2 : 2003 | Identical |
DIN EN 12412-2:2003-11 | Identical |
NS EN 12412-2 : 1ED 2003 | Identical |
BS EN 12412-2:2003 | Identical |
SN EN 12412-2 : 2003 | Identical |
UNI EN 12412-2 : 2004 | Identical |
BS ISO 18292:2011 | Energy performance of fenestration systems for residential buildings. Calculation procedure |
10/30234542 DC : 0 | BS EN ISO 12631 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
16/30310958 DC : 0 | BS EN ISO 12631 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
04/30113929 DC : DRAFT MAY 2004 | EN ISO 10077-1 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL |
15/30323246 DC : 0 | BS EN ISO 10077-2 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES |
I.S. EN ISO 12631:2017 | THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE (ISO 12631:2017) |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
UNE-EN ISO 10077-1:2010 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General |
BS EN 1873 : 2014 | PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS |
DIN EN 15603:2008-07 | ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS |
DIN EN 13947:2007-03 | THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
DIN EN 13830:2015-07 | CURTAIN WALLING - PRODUCT STANDARD |
BS EN ISO 12631:2017 | Thermal performance of curtain walling. Calculation of thermal transmittance |
09/30196724 DC : 0 | BS ISO 18292 - ENERGY PERFORMANCE OF FENESTRATION SYSTEMS - CALCULATION PROCEDURE |
BS EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters. Calculation of thermal transmittance Numerical method for frames |
PREN ISO 10077-2 : DRAFT 2009 | THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES |
UNI EN 15603 : 2008 | ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS |
ISO 12631:2017 | Thermal performance of curtain walling — Calculation of thermal transmittance |
EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
I.S. EN 13830:2015 | CURTAIN WALLING - PRODUCT STANDARD |
I.S. EN 1873:2014 | PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS |
DIN EN 1873:2016-07 | PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS |
UNE-EN 13947:2011 | Thermal performance of curtain walling - Calculation of thermal transmittance |
UNE-EN ISO 10077-2:2012 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2012) |
00/106948 DC : DRAFT OCT 2000 | PREN 13947 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
BS EN 15603:2008 | Energy performance of buildings. Overall energy use and definition of energy ratings |
ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
ISO 18292:2011 | Energy performance of fenestration systems for residential buildings Calculation procedure |
UNE-EN 13830:2016 | Curtain walling - Product standard |
EN 13830:2015 | Curtain walling - Product standard |
06/30149044 DC : DRAFT APR 2006 | EN 13947 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
I.S. EN ISO 10077-1:2017 | THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL (ISO 10077-1:2017) |
I.S. EN ISO 10077-2:2017 | THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES (ISO 10077-2:2017) |
BS EN 13947:2006 | Thermal performance of curtain walling. Calculation of thermal transmittance |
UNE-EN 1873:2015 | Prefabricated accessories for roofing - Individual rooflights of plastics - Product specification and test methods |
BS EN 13830:2015 | Curtain walling. Product standard |
EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
EN 13947:2006 | Thermal performance of curtain walling - Calculation of thermal transmittance |
EN 15603:2008 | Energy performance of buildings - Overall energy use and definition of energy ratings |
EN 1873:2014+A1:2016 | Prefabricated accessories for roofing - Individual rooflights of plastics - Product specification and test methods |
EN ISO 12631:2017 | Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017) |
12/30237844 DC : 0 | BS ISO 16346 - ENERGY PERFORMANCE OF BUILDINGS - ASSESSMENT OF OVERALL ENERGY PERFORMANCE |
I.S. EN 13947:2006 | THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE |
09/30196505 DC : 0 | BS EN ISO 10077-2 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES |
I.S. EN 15603:2008 | ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS |
EN 1946-4:2000 | Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 4: Measurements by hot box methods |
EN ISO 8990:1996 | Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box (ISO 8990:1994) |
EN ISO 9288:1996 | Thermal insulation - Heat transfer by radiation - Physical quantities and definitions (ISO 9288:1989) |
ISO 12567-1:2010 | Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors |
EN 12664:2001 | Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance |
ISO 9288:1989 | Thermal insulation — Heat transfer by radiation — Physical quantities and definitions |
PREN 12519 : DRAFT 1996 | DOORS AND WINDOWS - TERMINOLOGY |
ISO 8990:1994 | Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.