• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

EN 12412-2:2003

Current

Current

The latest, up-to-date edition.

Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames

Published date

16-07-2003

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols, units and subscripts
4 Principle
5 Requirements for test specimen and apparatus
  5.1 General
  5.2 Surround panels
  5.3 Specimen requirements and location
      5.3.1 Complete frames for windows and doors
      5.3.2 Frame and sash, transom or mullion profile sections
  5.4 Calibration panels
  5.5 Temperature measurement and baffle positions
6 Test procedure
  6.1 General
  6.2 Calibration measurements
      6.2.1 General
      6.2.2 Total surface resistance
      6.2.3 Surface resistances and surface coefficients of heat
        transfer
      6.2.4 Surround panel and edge effects
  6.3 Measurement procedure for test specimens
7 Test report
Annex A (normative) Determination of environmental temperature
  A.1 General
  A.2 Environmental temperature
  A.3 Mean radiant temperature
  A.4 Convective surface heat transfer coefficient
Annex B (normative) Linear thermal transmittance of the
        edge zone
Annex C (informative) Example of calibration test and
        measurement of frame specimen
  C.1 Calibration test with panel size 1,23 m x 1,48 m
  C.2 Frame specimen measurement

This European Standard specifies a method, based on EN ISO 8990 and EN ISO 12567-1, to measure the thermal transmittance of frame and sash components of windows and doors, including mullions and transoms.The thermal bridging effect of window or door components (handles, hinges, closing devices, etc.) is included.The test procedure is designed to take into account the whole developed area of the frame or sash surface, but excludes the influence of the thermal bridge introduced through the spacer in sealed glazing units.Edge effects occurring outside of the perimeter of the specimen are excluded. Furthermore, energy transfer due to solar radiation is not taken into account, and air leakage is excluded.The measurements are performed under defined conditions to facilitate the comparison of measured values.Information on the design of the calibration transfer standard is given in EN ISO 12567-1.

Committee
CEN/TC 89
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

BS ISO 18292:2011 Energy performance of fenestration systems for residential buildings. Calculation procedure
10/30234542 DC : 0 BS EN ISO 12631 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
16/30310958 DC : 0 BS EN ISO 12631 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
04/30113929 DC : DRAFT MAY 2004 EN ISO 10077-1 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL
15/30323246 DC : 0 BS EN ISO 10077-2 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES
I.S. EN ISO 12631:2017 THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE (ISO 12631:2017)
ISO 10077-1:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General
UNE-EN ISO 10077-1:2010 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General
BS EN 1873 : 2014 PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS
DIN EN 15603:2008-07 ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS
DIN EN 13947:2007-03 THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
DIN EN 13830:2015-07 CURTAIN WALLING - PRODUCT STANDARD
BS EN ISO 12631:2017 Thermal performance of curtain walling. Calculation of thermal transmittance
09/30196724 DC : 0 BS ISO 18292 - ENERGY PERFORMANCE OF FENESTRATION SYSTEMS - CALCULATION PROCEDURE
BS EN ISO 10077-2:2017 Thermal performance of windows, doors and shutters. Calculation of thermal transmittance Numerical method for frames
PREN ISO 10077-2 : DRAFT 2009 THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES
UNI EN 15603 : 2008 ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS
ISO 12631:2017 Thermal performance of curtain walling — Calculation of thermal transmittance
EN ISO 10077-2:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017)
I.S. EN 13830:2015 CURTAIN WALLING - PRODUCT STANDARD
I.S. EN 1873:2014 PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS
DIN EN 1873:2016-07 PREFABRICATED ACCESSORIES FOR ROOFING - INDIVIDUAL ROOFLIGHTS OF PLASTICS - PRODUCT SPECIFICATION AND TEST METHODS
UNE-EN 13947:2011 Thermal performance of curtain walling - Calculation of thermal transmittance
UNE-EN ISO 10077-2:2012 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2012)
00/106948 DC : DRAFT OCT 2000 PREN 13947 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
BS EN 15603:2008 Energy performance of buildings. Overall energy use and definition of energy ratings
ISO 10077-2:2017 Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames
ISO 18292:2011 Energy performance of fenestration systems for residential buildings Calculation procedure
UNE-EN 13830:2016 Curtain walling - Product standard
EN 13830:2015 Curtain walling - Product standard
06/30149044 DC : DRAFT APR 2006 EN 13947 - THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
I.S. EN ISO 10077-1:2017 THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 1: GENERAL (ISO 10077-1:2017)
I.S. EN ISO 10077-2:2017 THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES (ISO 10077-2:2017)
BS EN 13947:2006 Thermal performance of curtain walling. Calculation of thermal transmittance
UNE-EN 1873:2015 Prefabricated accessories for roofing - Individual rooflights of plastics - Product specification and test methods
BS EN 13830:2015 Curtain walling. Product standard
EN ISO 10077-1:2017 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02)
EN 13947:2006 Thermal performance of curtain walling - Calculation of thermal transmittance
EN 15603:2008 Energy performance of buildings - Overall energy use and definition of energy ratings
EN 1873:2014+A1:2016 Prefabricated accessories for roofing - Individual rooflights of plastics - Product specification and test methods
EN ISO 12631:2017 Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017)
12/30237844 DC : 0 BS ISO 16346 - ENERGY PERFORMANCE OF BUILDINGS - ASSESSMENT OF OVERALL ENERGY PERFORMANCE
I.S. EN 13947:2006 THERMAL PERFORMANCE OF CURTAIN WALLING - CALCULATION OF THERMAL TRANSMITTANCE
09/30196505 DC : 0 BS EN ISO 10077-2 - THERMAL PERFORMANCE OF WINDOWS, DOORS AND SHUTTERS - CALCULATION OF THERMAL TRANSMITTANCE - PART 2: NUMERICAL METHOD FOR FRAMES
I.S. EN 15603:2008 ENERGY PERFORMANCE OF BUILDINGS - OVERALL ENERGY USE AND DEFINITION OF ENERGY RATINGS

EN 1946-4:2000 Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 4: Measurements by hot box methods
EN ISO 8990:1996 Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box (ISO 8990:1994)
EN ISO 9288:1996 Thermal insulation - Heat transfer by radiation - Physical quantities and definitions (ISO 9288:1989)
ISO 12567-1:2010 Thermal performance of windows and doors Determination of thermal transmittance by the hot-box method Part 1: Complete windows and doors
EN 12664:2001 Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance
ISO 9288:1989 Thermal insulation — Heat transfer by radiation — Physical quantities and definitions
PREN 12519 : DRAFT 1996 DOORS AND WINDOWS - TERMINOLOGY
ISO 8990:1994 Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box
ISO 7345:1987 Thermal insulation Physical quantities and definitions

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.