• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 60601-2-4 : 2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - PART 2-4: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CARDIAC DEFIBRILLATORS (IEC 60601-2-4:2010)

Superseded date

04-09-2021

Superseded by

DIN EN 60601-2-4:2021-09

Published date

12-01-2013

Sorry this product is not available in your region.

INTRODUCTION
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
4 General requirements for tests
5 Classification
6 Identification, marking and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
10 Environmental conditions
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK
HAZARDS
14 Requirements related to classification
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
    CURRENTS
20 Dielectric strength
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
SECTION FIVE - PROTECTION AGAINST HAZARDS FROM
UNWANTED OR EXCESSIVE RADIATION
36 Electromagnetic compatibility (EMC)
SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF
FLAMMABLE ANAESTHETIC MIXTURES
SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES
AND OTHER SAFETY HAZARDS
42 Excessive temperatures
44 Overflow, spillage, leakage, humidity, ingress of
    liquids, cleaning, sterilization, disinfection and
    compatibility
46 Human errors
SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
AGAINST HAZARDOUS OUTPUT
50 Accuracy of operating data
51 Protection against hazardous output
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS;
ENVIRONMENTAL TESTS
52 Abnormal operation and fault conditions
SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
56 Components and general assembly
57 MAINS PARTS, components and layout
SECTION 101 - ADDITIONAL REQUIREMENTS RELATING TO SAFETY
101 Charging time
102 Internal electrical power source
103 Endurance
104 Synchronizer
105 Recovery of the MONITOR/ECG INPUT after defibrillation
106 Disturbance to the monitor from charging or internal
    discharging
Appendix L References - Publications mentioned in this
           Standard
Annex AA (informative) General guidance and rationale
Annex BB (informative) AUTOMATED EXTERNAL DEFIBRILLATORS:
         background and rationale
Annex ZA (normative) Normative references to international
         publications with their corresponding European
         publications
Annex ZB (informative) Other international publications
         mentioned in this standard with the reference of
         the European publications

DevelopmentNote
Supersedes DIN IEC 62D-181-CD and DIN VDE 0750-201. (07/2003) Applies in conjunction with DIN EN 60601-1 issue 07-2007. Supersedes DIN IEC 60601-2-4. (06/2012) DRAFT AMD 1 issued in February 2017. (02/2017)
DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy
Supersedes

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.