• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

DIN EN 60601-2-30 : 2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE SAFETY, INCLUDING ESSENTIAL PERFORMANCE, OF AUTOMATIC CYCLING NON-INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT

Superseded date

01-05-2011

Superseded by

DIN EN 80601-2-30 : 2016

Published date

12-01-2013

Sorry this product is not available in your region.

Vorwort
Einleitung
HAUPTABSCHNITT EINS - ALLGEMEINES
1 Anwendungsbereich und Zweck
2 Begriffe und Definitionen
3 Allgemeine Anforderungen
4 Allgemeines über die Prüfungen
5 Klassifikation
6 Bezeichnungen, Aufschriften und Begleitpapiere
HAUPTABSCHNITT ZWEI - UMWELTBEDINGUNGEN
HAUPTABSCHNITT DREI - SCHUTZ GEGEN DIE GEFAHR EINES
ELEKTRISCHEN SCHLAGES
14 Anforderungen in Bezug auf die Einteilung der Geräte
17 Trennung
19 Dauer-Ableit- und Patientenhilfsströme
20 Spannungsfestigkeit
HAUPTABSCHNITT VIER - SCHUTZ GEGEN MECHANISCHE GEFÄHRDUNG
21 Mechanische Festigkeit
22 Bewegte Teile
HAUPTABSCHNITT FÜNF - SCHUTZ GEGEN GEFAHREN DURCH UNERWÜNSCHTE
ODER ÜBERMÄSSIGE STRAHLUNG
36 Elektromagnetische Verträglichkeit
HAUPTABSCHNITT SECHS - SCHUTZ GEGEN GEFAHREN DURCH ZÜNDUNG
BRENNBARER GEMISCHE
HAUPTABSCHNITT SIEBEN - SCHUTZ GEGEN ÜBERMÄSSIGE TEMPERATUREN
UND ANDERE GEFÄHRDUNGEN
42 Übermässige Temperaturen
44 Überlaufen, Verschütten, Auslaufen, Feuchte, Eindringen
   von Flüssigkeit, Reinigung, Sterilisation und Desinfektion
45 Druckbehälter und durch Druck beanspruchte Teile
49 Unterbrechung der Stromversorgung
HAUPTABSCHNITT ACHT - GENAUIGKEIT DER BETRIEBSDATEN UND
SCHUTZ GEGEN GEFÄHRDENDE AUSGANGSWERTE
50 Genauigkeit der Betriebsdaten
51 Schutz gegen gefährdende Ausgangswerte
HAUPTABSCHNITT NEUN - NICHT BESTIMMUNGSGEMÄSSER BETRIEB
UND FEHLERFÄLLE; UMWELTPRÜFUNGEN
HAUPTABSCHNITT ZEHN - KONSTRUKTIVE ANFORDERUNGEN
56 Bauelemente und Allgemeines zum Zusammenbau
57 Netzteile, Bauteile und Ausführung
Anhang L (normativ) Schriftstücke, auf die in dieser Norm
          Bezug genommen wird
Anhang AA (informativ) Allgemeine Erklärung und Begründung
Anhang BB (informativ) Alarm-Diagramme
Anhang ZA (normativ) Normative Verweisungen auf Internationale
          Publikationen mit ihren entsprechenden Europäischen
          Publikationen
Anhang ZB (informativ) Andere in dieser Norm zitierte
          internationale Publikationen mit den Verweisungen auf
          die entsprechenden europäischen Publikationen

Specifies criteria for safety and essential performance of AUTOMATIC CYCLING NON-INVASIVE BLOOD PRESSURE MONITORING EQUIPMENT, (referred to as equipment). The equipment may be attended or unattended. Does not apply to blood pressure measuring equipment which uses finger transducers or to semi-automatic blood pressure measuring equipment, where each determination typically needs to be initiated manually.

DevelopmentNote
Supersedes DIN IEC 62D-289-CDV. (03/2003)
DocumentType
Standard
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

Standards Relationship
I.S. EN 60601-2-30:2000 Identical
IEC 60601-2-30:1999 Identical
VDE 0750-2-30 : 2016 Corresponds
EN 60601-2-30:2000 Identical
SN EN 60601-2-30 : 2000 Identical
UNE-EN 60601-2-30:2001 Identical
BS EN 60601-2-30:2000 Identical
NF EN 60601-2-30 : 2002 Identical

HD 395.2.2 : 200S1 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE SAFETY OF HIGH FREQUENCY SURGICAL EQUIPMENT
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
DIN EN 60601-2-2 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-2: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH FREQUENCY SURGICAL EQUIPMENT AND HIGH FREQUENCY SURGICAL ACCESSORIES
VDE 0847-4-6 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
DIN VDE 0470-1 : 1992
VDE 0750-1-2 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES REQUIREMENTS AND TESTS (IEC 60601-1-2:2014)
VDE 0750-2-2 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-2: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF HIGH FREQUENCY SURGICAL EQUIPMENT AND HIGH FREQUENCY SURGICAL ACCESSORIES
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
VDE 0847-4-8 : 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
IEC 61000-4-6:2013 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-2:2017 Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories
DIN EN 61000-4-6 : 2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
DIN EN 61000-4-3 : 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
DIN EN 61000-4-8 : 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
EN 60601-1-4:1996/A1:1999 MEDICAL ELECTRICAL EQUIPMENT - GENERAL REQUIREMENTS FOR SAFETY - COLLATERAL STANDARD: PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
VDE 0750-1-4 : 2001 MEDICAL ELECTRICAL EQUIPMENT - PART 1-4: GENERAL REQUIREMENTS FOR SAFETY; COLLATERAL STANDARD: PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS
VDE 0847-4-3 : 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
VDE 0750-1 : 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005 + COR.:2006 + COR.:2007 + A1:2012)
IEC 60601-1-4:1996+AMD1:1999 CSV Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems
DIN EN 55011 : 2011 INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 11:2015, MODIFIED + A1:2017)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.