• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS IEC 62232:2011

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

Available format(s)

Hardcopy , PDF

Withdrawn date

10-02-2018

Superseded by

BS EN 62232:2017

Language(s)

English

Published date

31-07-2011

£356.00
Excluding VAT

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Developing the evaluation plan
6 Evaluation methods
7 Uncertainty
8 Reporting
Annex A (normative) - Developing the evaluation
        plan
Annex B (normative) - Defining the source-environment
        plane
Annex C (informative) - Guidance on the application
        of the standard to specific evaluation purposes
Annex D (normative) - Evaluation parameters
Annex E (normative) - RF field strength measurement
        equipment requirements
Annex F (informative) - Basic computation implementation
Annex G (normative) - Advanced computation implementation
Annex H (normative) - Validation of computation methods
Annex I (informative) - Guidance on spatial averaging schemes
Annex J (informative) - Guidance on addressing time
        variation of signals in measurement
Annex K (informative) - Guidance on determining ambient field
        levels
Annex L (informative) - Guidance on comparing evaluated
        parameters with a limit value
Annex M (informative) - Guidance on assessment schemes
Annex N (informative) - Guidance on specific technologies
Annex O (informative) - Guidance on uncertainty
Annex P (informative) - Case studies
Bibliography

Gives methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure.

Committee
GEL/106
DevelopmentNote
Supersedes 08/30136850 DC. (08/2011)
DocumentType
Standard
Pages
184
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy
Supersedes

This International Standard provides methods for the determination of radio-frequency (RF) field strength and specific absorption rate (SAR) in the vicinity of radiocommunication base stations (RBS) for the purpose of evaluating human exposure. This standard: considers RBS which transmit on one or more antennas using one or more frequencies in the range 300 MHz to 6 GHz; describes several RF field strength and SAR measurement and computation methodologies with guidance on their applicability to address both the in situ evaluation of installed RBS and laboratory-based evaluations; describes how surveyors with a sufficient level of expertise shall establish their specific evaluation procedures appropriate for their evaluation purpose; considers the evaluation purposes, namely: product conformity: to establish that a RBS conforms to a defined set of limit conditions under its intended use; compliance boundary: to establish the compliance boundary or boundaries for a RBS in relation to a defined set of limit conditions; to evaluate RF field strength or SAR values at one or more evaluation locations, namely: evaluation location(s) at arbitrary locations outside the control boundary to provide information for interested parties; evaluation location(s) at the control boundary to confirm validity of control boundary; evaluation location(s) within the control boundary with the specific conditions relevant to investigate an alleged over-exposure incident; provides guidance on how to report, interpret and compare results from different evaluation methodologies and, where the evaluation purpose requires it, determine a justified decision against a limit value; provides informative guidance on how to evaluate ambient RF field strength levels in the vicinity of a RBS from RF sources other than the RBS under evaluation and at frequencies within and outside the range 300 MHz to 6 GHz; provides short descriptions of the informative example case studies to aid the surveyor given in the companion Technical Report IEC 62669 [54].

Standards Relationship
IEC 62232:2017 Identical
IEC 62232:2011 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEC 60050-394:2007 International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors
IEC 62209-2:2010 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)
CISPR 16-4-2:2011+AMD1:2014 CSV Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty
IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 60050-531:1974 International Electrotechnical Vocabulary (IEV) - Part 531: Electronic tubes
IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 60215:2016 Safety requirements for radio transmitting equipment - General requirements and terminology
CISPR TR 16-4-1:2009 Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests
IEEE C95.3-2002 IEEE Recommended Practice for Measurements and Computations of Radio Frequency Electromagnetic Fields With Respect to Human Exposure to Such Fields, 100 kHz-300 GHz
EN 50492 : 2008 AMD 1 2014 BASIC STANDARD FOR THE IN-SITU MEASUREMENT OF ELECTROMAGNETIC FIELD STRENGTH RELATED TO HUMAN EXPOSURE IN THE VICINITY OF BASE STATIONS
IEC TR 62630:2010 Guidance for evaluating exposure from multiple electromagnetic sources
IEEE C95.1-2005 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz
IEC 62311:2007 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
IEEE 145-2013 REDLINE IEEE Standard for Definitions of Terms for Antennas
IEC 60050-121:1998 International Electrotechnical Vocabulary (IEV) - Part 121: Electromagnetism
TR 102 457 : 1.1.1 TRANSMISSION AND MULTIPLEXING (TM); STUDY ON THE ELECTROMAGNETIC RADIATED FIELD IN FIXED RADIO SYSTEMS FOR ENVIRONMENTAL ISSUES
IEC 60050-705:1995 International Electrotechnical Vocabulary (IEV) - Part 705: Radio wave propagation
IEC 60050-712:1992 International Electrotechnical Vocabulary (IEV) - Part 712: Antennas
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)
IEC TR 62669:2011 Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.