BS EN 54-13:2017

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection and fire alarm systems Compatibility and connectability assessment of system components

Available format(s)

Hardcopy , PDF

Superseded date

05-02-2020

Superseded by

BS EN 54-13:2017+A1:2019

Language(s)

English

Published date

28-02-2017

£218.00
Excluding VAT

European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Assessment methods and tests
Annex A (informative) - Example of levels used
        in FDAS
Annex B (informative) - Classification of functions
        of the FDAS
Annex C (informative) - Example methodology for
        theoretical analysis
Annex D (normative) - Software design documentation
Annex E (informative) - Flowchart for assessment of
        compatibility/connectability

Defines the requirements for compatibility and connectability assessment of components of fire detection and fire alarm system or voice alarm system as a subsystem of fire detection and fire alarm system.

Committee
FSH/12/3
DevelopmentNote
Supersedes 96/542173 DC. (09/2005) Supersedes 14/30290848 DC. (02/2017)
DocumentType
Standard
Pages
36
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This European Standard specifies the requirements for compatibility and connectability assessment of components of fire detection and fire alarm systems (including voice alarm systems as a subsystem of fire detection and fire alarm system). The components conform to either with the requirements of EN54 or with a manufacturer’s specification where there is no EN54 standard. The requirements for the transmission path used for a distributed function are covered by the relevant EN54 standard and not by this document. This document also specifies requirements for the integrity of the fire detection and fire alarm system when connected to other systems. This document does not specify the manner in which the system is designed, installed and used in any particular application. This document recognizes that it is not practical to assess the compatibility or connectability of components in all possible configurations. Methods of assessment are specified to reach an acceptable degree of confidence within pre-determined operational and environmental conditions. This document specifies requirements related to compatibility and connectability assessment methods and tests for the components belonging to FDAS or connecting FDAS. This document does not cover components or functions which are not included in a FDAS like functions achieved by a building management system. This document is applicable to systems where the components are interconnected by electrical wires or optical fibre or by radio frequency links or by any combination. For other interconnection technology between components this standard may be used as a guidance. NOTE Other European Standards are expected to cover the requirements of the other systems which may be connected to the fire detection and fire alarm system.

Standards Relationship
SN EN 54-13 : 2017 Identical
NBN EN 54-13 : 2005 Identical
NEN EN 54-13 : 2017 Identical
DIN EN 54-13:2014-09 (Draft) Identical
ONORM EN 54-13 : 2017 Identical
UNE-EN 54-13:2006 Identical
NF EN 54-13 : 2017 Identical
I.S. EN 54-13:2017 Identical
NS EN 54-13 : 2017 Identical
EN 54-13:2017 Identical
UNI EN 54-13 : 2005 Identical

BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
PD 6686:2006 Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
01/540647 DC : DRAFT MAY 2001 BS 5839-1 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 1 - CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION AND MAINTENANCE

EN 54-16:2008 Fire detection and fire alarm systems - Part 16: Voice alarm control and indicating equipment
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.