• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

ASTM D 5175 : 1991 : R2017 : EDT 1

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Organohalide Pesticides and Polychlorinated Biphenyls in Water by Microextraction and Gas Chromatography

Available format(s)

Hardcopy , PDF

Superseded date

06-05-2024

Language(s)

English

Published date

05-01-2018

£63.73
Excluding VAT

CONTAINED IN VOL. 11.02, 2018 Pertains to the determination of a number of analytes (listed in the document) in drinking water during intermediate stages of treatment, finished drinking water, and the raw source water.

Committee
D 19
DocumentType
Test Method
Pages
12
ProductNote
Reconfirmed EDT 1
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

1.1This test method (1-3)2 is applicable to the determination of the following analytes in finished drinking water, drinking water during intermediate stages of treatment, and the raw source water:

 Analyte

Chemical Abstract Service
Registry Number A

Alachlor

5972-60-8

Aldrin

309-00-2

Chlordane

57-74-9

Dieldrin

60-57-1

Endrin

72-20-8

Heptachlor

76-44-8

Heptachlor Epoxide

1024-57-3

Hexachlorobenzene

118-74-1

Lindane

58-89-9

Methoxychlor

72-43-5

Toxaphene

8001-35-2

Aroclor B 1016

12674-11-2

Aroclor B 1221

11104-28-2

Aroclor B 1232

11141-16-5

Aroclor B 1242

53469-21-9

Aroclor B 1248

12672-29-6

Aroclor B 1254

11097-69-1

Aroclor B 1260

11096-82-5

(A)Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.
(B)Aroclor is a registered trademark of Monsanto Co.

1.2Detection limits for most test method analytes are less than 1 μg/L. Actual detection limits are highly dependent on the characteristics of the sample matrix and the gas chromatography system. Table 1 contains the applicable concentration range for the precision and bias statements. Only Aroclor 1016 and 1254 were included in the interlaboratory test used to derive the precision and bias statements. Data for other PCB products are likely to be similar.

(A)Bias = C − X.
(B)X  = Mean recovery.
(C)C = True concentration value.
(D)St = Overall standard deviation.
(E)So = Single analyst standard deviation.

1.3Chlordane, toxaphene, and Aroclor products (polychlorinated biphenyls) are multicomponent materials. Precision and bias statements reflect recovery of these materials dosed into water samples. The precision and bias statements may not apply to environmentally altered materials or to samples containing complex mixtures of polychlorinated biphenyls (PCBs) and organochlorine pesticides.

1.4For compounds other than those listed in 1.1 or for other sample sources, the analyst must demonstrate the applicability of this test method by collecting precision and bias data on spiked samples (groundwater, tap water) (4) and provide qualitative confirmation of results by gas chromatography/mass spectrometry (GC/MS) (5) or by GC analysis using dissimilar columns.

1.5This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and in the interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedure described in Section 13.

1.6Analytes that are not separated chromatographically, (analytes that have very similar retention times) cannot be individually identified and measured in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 13.4).

1.7When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.

1.8The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

1.9This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.

1.10This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM D 5241 : 1992 : R2017 Standard Practice for Micro-Extraction of Water for Analysis of Volatile and Semi-Volatile Organic Compounds in Water
ASTM D 3694 : 1996 : R2017 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents
ASTM D 3694 : 1996 : R2024 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 1129 : 2003 Standard Terminology Relating to Water
ASTM D 1129 : 2013 Standard Terminology Relating to Water
ASTM D 1129 : 2013 : R2020 Standard Terminology Relating to Water
ASTM D 1129 : 2013 : R2020 : EDT 2 Standard Terminology Relating to Water
ASTM D 1193 : 1977 : R1983 : EDT 1 Standard Specification for Reagent Water
ASTM D 4128 : 2018 Standard Guide for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry
ASTM D 1129 : 2006 Standard Terminology Relating to Water
ASTM D 1129 : 2013 : R2020 : EDT 1 Standard Terminology Relating to Water
ASTM D 1129 : 1999 : REV A Standard Terminology Relating to Water
ASTM D 4128 : 2001 Standard Guide for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry
ASTM D 3856 : 2011 Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water
ASTM D 1129 : 2006 : REV A Standard Terminology Relating to Water
ASTM D 1193 : 2006 : R2011 Standard Specification for Reagent Water
ASTM D 1129 : 2003 : REV A Standard Terminology Relating to Water
ASTM D 1129 : 2002 Standard Terminology Relating to Water
ASTM D 3534 : 1985 : R1995 : EDT 1 Standard Test Method for Polychlorinated Biphenyls (PCBs) in Water (Withdrawn 2004)
ASTM E 355 : 1996 : R2021 : EDT 1 Standard Practice for Gas Chromatography Terms and Relationships
ASTM D 1193 : 1991 Standard Specification for Reagent Water
ASTM D 3856 : 1995 : R2006 Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water
ASTM D 1129 : 2004 Standard Terminology Relating to Water
CFR 29(PT1910.1000 TO END) : 0 LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR
ASTM D 4128:2006 Standard Guide for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry
ASTM D 3856 : 2011 : R2015 Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water (Withdrawn 2024)
ASTM D 3856 : 1995 : R2000 Standard Guide for Good Laboratory Practices in Laboratories Engaged in Sampling and Analysis of Water
ASTM D 1129 : 2002 : REV A Standard Terminology Relating to Water
ASTM D 1193 : 1970 Standard Specification For Reagent Water
ASTM D 1193 : 2006 Standard Specification for Reagent Water
ASTM D 1193 : 1999 Standard Specification for Reagent Water
ASTM D 1129 : 2010 Standard Terminology Relating to Water
ASTM D 4128 : 2006 : R2012 Standard Guide for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry
ASTM D 4210 : 1989 : R1996 : EDT 1 Standard Practice for Intralaboratory Quality Control Procedures and a Discussion on Reporting Low-Level Data (Withdrawn 2002)
ASTM E 355 : 1996 : R2014 Standard Practice for Gas Chromatography Terms and Relationships
ASTM D 1129 : 2006 : REV A : EDT 1 Standard Terminology Relating to Water
ASTM D 1129 : 2001 Standard Terminology Relating to Water
ASTM D 1129 : 2004 : EDT 1 Standard Terminology Relating to Water
ASTM D 1193 : 2006 : R2018 Standard Specification for Reagent Water
ASTM D 4128 : 1994 Standard Practice for Identification and Quantitation of Organic Compounds in Water by Combined Gas Chromatography and Electron Impact Mass Spectrometry

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.