AS/NZS 5139:2019

Current

Current

The latest, up-to-date edition.

Electrical installations - Safety of battery systems for use with power conversion equipment

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-10-2019

Preview
£143.75
Excluding VAT

AS NZS 5139 2019 specifies requirements for general installation and safety requirements for battery energy storage systems (BESSs), where the battery system is installed in a location, such as a dedicated enclosure or room, and is connected with power conversion equipment (PCE) to supply electric power to other parts of an electrical installation.

Committee
EL-042
DocumentType
Standard
ISBN
978 1 76072 586 0
Pages
160
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out general installation and safety requirements for battery energy storage systems (BESSs), where the battery system is installed in a location, such as a dedicated enclosure or room, and is connected with power conversion equipment (PCE) to supply electric power to other parts of an electrical installation.
This Standard sets out the requirements from the battery system up to but not including the PCE. This Standard also applies to pre-assembled integrated battery energy storage systems, which also include PCE(s).
This Standard outlines the potential hazards that are associated with battery energy storage systems and their associated battery systems and specifies installation methods that minimize risks posed by these hazards.
This Standard is applicable for the following battery systems:
(a) Nominal voltage between 12 V d.c. and 1500 V d.c.
(b) Connected to either single or multiple PCEs.
(c) Using secondary or rechargeable cells.
(d) With a rated capacity equal to or greater than 1 kWh and no more than 200 kWh, at —
(i) C10 rating, for lead acid batteries; or
(ii) 0.1C, for lithium technologies; or
(iii) manufacturer’s specified energy capacity, for other technologies.
Where an installation includes multiple battery energy storage systems, this Standard applies to each individual battery energy storage system if —
(A) the total energy storage capacity is equal to or greater than 1 kWh; and
(B) each individual BESS is no more than 200 kWh.
This Standard does not apply to battery systems in the following electrical installation types:
(1) Premises with critical power continuity requirements (e.g. acute care hospitals, substation support and black start).
(2) Telecommunication applications.
(3) Electric vehicles.
(4) Portable equipment.
(5) Uninterruptible power systems (UPS) that are in accordance with AS 62040.1.1 and AS 62040.1.2.
(6) Transportable structures and vehicles that are in accordance with AS/NZS 3001.
NOTE 1 While this Standard applies to systems of up to 200 kWh, the general requirements of this Standard may apply to larger installations.
NOTE 2 This Standard applies for common BESS technologies, and is not specifically written to support all types of battery system installation types or for other storage technologies, e.g. super capacitors. This Standard may be able to be applied in full or in part to the different storage technologies, or the risk approach may be used to assess the hazards and determine mitigations.

Originated in Australia as AS 4086.2-1997.
Jointly revised and redesignated as AS/NZS 5139:2019.

AS 60947.3:2018 Low voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fusecombination units (IEC 60947-3:2015 (ED. 3.2) MOD)
AS 4029.1-1994 Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1)
ISO 9773:1998 Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV Low-voltage fuses - Part 1: General requirements
AS/NZS 4777.1:2016 Grid connection of energy systems via inverters Installation requirements
AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
IEC 60896-21:2004 Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
AS/NZS 3008.1.2:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
SAA/SNZ HB 76:2010 Dangerous Goods - Initial Emergency Response Guide
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
AS/NZS IEC 60947.1:2015 Low-voltage switchgear and controlgear General rules
AS 62040.1.1-2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas
AS/NZS 4029.2:2000 Stationary batteries - Lead-acid Valve-regulated type (IEC 60896-2:1995, MOD)
AS 3731.1-1995 Stationary batteries - Nickel-cadmium Vented type
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
AS/NZS 3001:2008 Electrical installations - Transportable structures and vehicles including their site supplies
IEC 60896-22:2004 Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements
IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
AS/NZS IEC 60947.2:2015 Low-voltage switchgear and controlgear Circuit-breakers
AS/NZS 60079.14:2017 Explosive atmospheres Design selection, erection and initial inspection (IEC 60079-14:2013 (ED.5.0) MOD)
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 4777.2:2015 Grid connection of energy systems via inverters Inverter requirements
AS 62040.1.2-2003 Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations
IEC 60896-11:2002 Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests
AS/NZS 5000.1:2005 Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)
AS/NZS 1680.1:2006 Interior and workplace lighting General principles and recommendations
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS/NZS 1170.2:2011 Structural design actions Wind actions (Reconfirmed 2016)
AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
AS/NZS 5033:2014 Installation and safety requirements for photovoltaic (PV) arrays
AS/NZS ISO 31000:2009 Risk management - Principles and guidelines
AS 1530.1-1994 Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016)
IEC 62109-1:2010 Safety of power converters for use in photovoltaic power systems - Part 1: General requirements
AS/NZS 60898.2:2004 Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. and d.c. operation (IEC 60898-2, Ed. 1.1 (2003) MOD) (Reconfirmed 2016)
AS/NZS 3112:2017 Approval and test specification - Plugs and socket-outlets
AS/NZS 4509.1:2009 Stand-alone power systems Safety and installation (Reconfirmed 2017)
AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017)
AS 3731.2-1995 Stationary batteries - Nickel-cadmium Valve-regulated type
IEC 60695-11-20:2015 Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
ISO 9772:2012 Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame

AS 3011.2:2019 Electrical installations - Secondary batteries installed in buildings Sealed cells
AS 2676.2:2020 Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings Sealed cells
AS 2676.1:2020 Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells
AS 3011.1:2019 Electrical installations - Secondary batteries installed in buildings Vented cells

You may also be interested in AS 60947.3:2018

Specifies requirements for switches, disconnectors, switch-disconnectors and fuse-combination units to be used in distribution circuits and motor circuits of which the rated voltage does not exceed 1000V a.c. or 1500V d.c.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.