Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 12150-2:2004

Current

Current

The latest, up-to-date edition.

Glass in building. Thermally toughened soda lime silicate safety glass Evaluation of conformity/Product standard

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

18-10-2004

$520.16
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
  4.1 Product description
  4.2 Conformity with the definition of thermally strengthened
      soda lime silicate safety glass
  4.3 Determination of the characteristic's performances
      4.3.1 Characteristics of thermally strengthened soda
            lime silicate safety glass
      4.3.2 Determination of characteristics of thermally
            strengthened soda lime silicate safety glass products
  4.4 Durability
  4.5 Dangerous substances
5 Evaluation of conformity
  5.1 General
  5.2 Initial type testing of the product
      5.2.1 General
      5.2.2 Initial type testing of thermally strengthened
            soda lime silicate safety glass
      5.2.3 Initial type testing of characteristic's performances
  5.3 Factory production control and inspection of samples in
      accordance with a prescribed test plan
  5.4 Initial inspection of factory and of factory production
      control
  5.5 Continuous surveillance and assessment of the factory
      production control
6 Marking and/or labelling
  6.1 General
  6.2 Product marking
  6.3 Product characteristics
  6.4 'Characteristics/performance identification paper'
Annex A (normative) Factory production control
  A.1 Factory Production Control Requirements
      A.1.1 General
      A.1.2 Organisation
      A.1.3 Control system
  A.2 Marking
  A.3 Inspection and testing tables of chemically strengthened
      soda lime silicate safety glass production
      A.3.1 Information on Table A.1
      A.3.2 Use of proxy testing
Annex B (informative) Test for factory production control
  B.1 Strength Measurement
      B.1.1 Four point bending strength test
      B.1.2 Optical surface pre-stress measurement
  B.2 Fragmentation test
      B.2.1 Requirements
      B.2.2 Test method
Annex C (informative) Provisions for voluntary involvement of
                      third party(ies)
  C.1 General
  C.2 Voluntary tasks for third parties
  C.3 Marking and labelling
Annex ZA (informative) Clauses of this European Standard addressing
                       the provisions of EU Construction Products
                       Directive
  ZA.1 Scope and relevant characteristics
  ZA.2 Procedure(s) for the attestation of conformity of
       thermally toughened soda lime silicate safety glass
       products
       ZA.2.1 System(s) of attestation of conformity
       ZA.2.2 EC Certificate and Declaration of conformity
  ZA.3 CE marking and labelling
Bibliography

Describes the evaluation of conformity and the factory production control of flat thermally toughened soda lime silicate safety glass for use in buildings.

Committee
B/520
DevelopmentNote
Supersedes 01/105365 DC (11/2004)
DocumentType
Standard
Pages
42
PublisherName
British Standards Institution
Status
Current
Supersedes

This document covers the evaluation of conformity and the factory production control of flat thermally toughened soda lime silicate safety glass for use in buildings. Note: For glass products with electrical wiring or connections for, e.g. alarm or heating purposes, other directives, e.g. Low Voltage Directive, may apply.

08/30143158 DC : DRAFT AUG 2008 BS 644 - TIMBER WINDOWS - FULLY FINISHED FACTORY ASSEMBLED WINDOWS OF VARIOUS TYPES - SPECIFICATION
BS 6262-7:2017 Glazing for buildings Code of practice for the provision of information
BS 6262-1:2017 Glazing for buildings General methodology for the selection of glazing
BS 7412:2007 Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles
06/30143171 DC : DRAFT SEP 2006 BS 7412 - PLASTICS WINDOWS AND DOORSETS MADE FROM UNPLASTICIZED POLYVINYL CHLORIDE (PVC-U) EXTRUDED HOLLOW PROFILES

PREN 13501-5 : DRAFT 2015 FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 5: CLASSIFICATION USING DATA FROM EXTERNAL FIRE EXPOSURE TO ROOFS TESTS
EN 673:2011 Glass in building - Determination of thermal transmittance (U value) - Calculation method
EN 12758:2011 Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties
EN 410:2011 Glass in building - Determination of luminous and solar characteristics of glazing
EN 1096-1:2012 Glass in building - Coated glass - Part 1: Definitions and classification
EN 12898:2001 Glass in building - Determination of the emissivity
EN 13541:2012 Glass in building - Security glazing - Testing and classification of resistance against explosion pressure
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 1288-3:2000 Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending)
EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
EN 12150-1:2015 Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN 1063:1999 Glass in building - Security glazing - Testing and classification of resistance against bullet attack
EN 572-4:2012 Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass
EN 357:2004 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance
ISO 9001:2015 Quality management systems — Requirements
EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
EN 356:1999 Glass in building - Security glazing - Testing and classification of resistance against manual attack
EN 572-5:2012 Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass
EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
EN 12600:2002 Glass in building - Pendulum test - Impact test method and classification for flat glass
EN 1096-2:2012 Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more