BS 7629-1:2015+A1:2019

Current

Current

The latest, up-to-date edition.

Electric cables. Specification for 300/500 V fire resistant, screened, fixed installation cables having low emission of smoke and corrosive gases when affected by fire Multicore cables

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

20-06-2019

$520.16
Including GST where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Voltage designation and fire resistance categories
5 Conductors and drain wire
6 Insulation
7 Identification of cores
8 Laying-up
9 Screen
10 Sheath
11 Cable marking and additional information
12 Schedule of tests
13 Test conditions
14 Routine tests
15 Sample tests
16 Type tests
Annexes
Annex A (informative) - Guide to selection, installation
         and operation
Annex B (normative) - Method of test for continuity of
        tinned coatings of wires
Annex C (normative) - Method of test for voltage withstand
Annex D (normative) - Method of test for bending
        characteristics
Annex E (normative) - Method of test for resistance to impact
Annex F (normative) - Method of test for shrinkage of sheath
        on cable during heat treatment
Annex G (informative) - Notes on type tests
Bibliography

Defines requirements and test methods for the construction and performance of cables which: - have thermosetting insulation and a rated voltage of 300/500 V; - provide resistance to fire (circuit integrity), including with mechanical shock and with water, as measured by performance in a standard test or tests; - emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; and - are primarily intended for use in emergency lighting, fire detection and fire alarm system circuits.

Committee
GEL/20/17
DocumentType
Standard
ISBN
978 0 580 99630 6
Pages
34
ProductNote
This standard also refers to Electricity Safety, Quality and Continuity Regulations 2002,
PublisherName
British Standards Institution
Status
Current
Supersedes

This British Standard specifies requirements and test methods for the construction and performance of cables which:

  • have thermosetting insulation and a rated voltage of300/500V;

  • provide resistance to fire (circuit integrity), including with mechanical shock and with water, as measured by performance in a standard test or tests;

  • emit limited amounts of smoke and corrosive gases when burned as measured by a standard test; and

  • are primarily intended for use in emergency lighting, fire detection and fire alarm system circuits.

The circuit integrity performance under fire conditions is assessed on the basis of tests which measure resistance to fire with mechanical impact and water spray (Categories: Standard30, Standard60and Enhanced120).

NOTE1 BS5266‑1and BS5839‑1give recommendations and guidance on the factors to be taken into account in the planning, design, installation, commissioning and maintenance of emergency lighting, fire detection and fire alarm systems for buildings, respectively.

It is applicable to2‑core,3‑core and4‑core circular cables with an uninsulated full-size circuit protective conductor (CPC), and7‑core,12‑core and19‑core circular multicore auxiliary cables with an uninsulated drain wire of not less than 0.5mm2. All cables contain a metallic layer, which provides electrostatic screening.

The cables are suitable for operation at a maximum sustained conductor temperature of70°C and for a maximum short‑circuit conductor temperature of250°C (for a maximum period of5s).

NOTE2 AnnexA gives recommendations for the selection, installation and operation of cables, AnnexB gives the method of test for continuity of tinned coating of wires, AnnexC gives the method of test for voltage withstand, AnnexD gives the method of test for bending characteristics, AnnexE gives the method of test for resistance to impact, AnnexF gives the method of test for shrinkage of sheath and AnnexG gives notes on type tests.

BS EN 60811-506:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Impact test at low temperature for insulations and sheaths
BS EN 61034-2 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS PART 2: TEST PROCEDURE AND REQUIREMENTS
BS 5266-1:2011 Emergency lighting Code of practice for the emergency escape lighting of premises
BS EN 60811-502:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Shrinkage test for insulations
BS EN 50200:2015 Method of test for resistance to fire of unprotected small cables for use in emergency circuits
BS EN 61034-1 : 2005 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS
BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
BS EN ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories
BS EN 60332-1-2 : 2004 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004)
BS EN 60228:2005 Conductors of insulated cables
BS 7671(2008) : 2008 REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS
BS EN 60079-14:2014 Explosive atmospheres Electrical installations design, selection and erection
BS 8434-2(2003) : 2003 METHODS OF TEST FOR ASSESSMENT OF THE FIRE INTEGRITY OF ELECTRIC CABLES - PART 2: TEST FOR UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS - BS EN 50200 WITH A 930 DEGREE C FLAME AND WITH WATER SPRAY
BS EN 50395 : 2005 ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice
BS EN 62230 : 2007 ELECTRIC CABLES - SPARK-TEST METHOD
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
BS EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
BS EN 50363-5 : 2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
BS EN 50396 : 2005 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
BS EN 60754-1:2014 Test on gases evolved during combustion of materials from cables Determination of the halogen acid gas content

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more