• Shopping Cart
    There are no items in your cart

ASTM E 2768 : 2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Standard Test Method for Extended Duration Surface Burning Characteristics of Building Materials (30 min Tunnel Test)

Available format(s)

Hardcopy , PDF

Superseded date

09-02-2020

Published date

07-01-2011

US$66.00
Excluding Tax where applicable

CONTAINED IN VOL. 04.07, 2014 Aims to evaluate the ability of a product to limit the surface spread of flame when evaluated for 30 min. This fire-test-response standard uses the apparatus and procedure of Test Method E84 with the total test period extended to 30 min.

Committee
E 05
DocumentType
Test Method
Pages
4
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy

1.1 The purpose of this fire-test-response standard is to evaluate the ability of a product to limit the surface spread of flame when evaluated for 30 min. This fire-test-response standard uses the apparatus and procedure of Test Method E84 with the total test period extended to 30 min.

1.2 Building applications affecting fire and life safety often require products with specific criteria for surface spread of flame and flame spread index. The resulting performance characteristics included in the conditions of classification for this fire-test-response standard are intended to be used for regulatory purposes to determine the suitability of materials or products for use in buildings under specified conditions where significantly reduced surface burning characteristics are required.

1.3 Materials and products that are beyond the scope of Test Method E84 are beyond the scope of this standard.

1.4 Materials or products which melt, drip or delaminate to the extent that the continuity of the flame front is destroyed are beyond the scope of this standard.

Note 1—Testing of materials that melt, drip, or delaminate to such a degree that the continuity of the flame-front is destroyed, results in low flame spread indices that do not relate directly to indices obtained by testing materials that remain in place. Materials or products that melt, drip, or delaminate, or that cannot support their own weight, have the potential for demonstrating reduced flame spread results as compared to the flame spread results where the materials or products remain in place during testing.

1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.6 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding tables and figures, shall not be considered as requirements of the standard.

1.7 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.9 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

NFPA 1144 : 2018 REDUCING STRUCTURE IGNITION HAZARDS FROM WILDLAND FIRE
NFPA 557 : 2016 DETERMINATION OF FIRE LOAD FOR USE IN STRUCTURAL FIRE PROTECTION DESIGN
NFPA 5000 : 2018 BUILDING CONSTRUCTION AND SAFETY CODE
ASTM D 3201/D3201M : 2013 : REDLINE Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products
NFPA 703 : 2018 FIRE RETARDANT-TREATED WOOD AND FIRE-RETARDANT COATINGS FOR BUILDING MATERIALS
NFPA 1 : 2021 FIRE CODE
ASTM E 84 : 2019 : REV B Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM D 3201/D3201M : 2013 Standard Test Method for Hygroscopic Properties of Fire-Retardant Wood and Wood-Based Products
ASTM D 5516 : 2018 Standard Test Method for Evaluating the Flexural Properties of Fire-Retardant Treated Softwood Plywood Exposed to Elevated Temperatures
NFPA 101 : 2018 LIFE SAFETY CODE
ICC IWUIC INTERNATIONAL WILDLAND U.I. CODE : 2015 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
ASTM D 7857 : 2016 Standard Test Method for Evaluating the Flexural Properties and Internal Bond Strength of Fire-Retarded Mat-Formed Wood Structural Composite Panels Exposed to Elevated Temperatures
NFPA 1 : 2018 FIRE CODE
NFPA 703:2024 Standard for Fire-Retardant-Treated Wood and Fire-Retardant Coatings for Building Materials

NFPA 101 : 2018 LIFE SAFETY CODE
ICC 2009 INTERNATIONAL RESI. CODE : 2009 INTERNATIONAL RESIDENTIAL CODE[R] FOR ONE- AND TWO-FAMILY DWELLINGS
ICC 2010 CALIFORNIA BUILDING CODE : 2010 CALIFORNIA BUILDING CODE, TITLE 24 - PART 2 (2 VOLUMES - INCLUDES PARTS 8 & 10)
ICC 2009 INTERNATIONAL BUILDING CODE : 2009 INTERNATIONAL BUILDING CODE
ICC 2009 INTERNATIONAL WILDLAND U.I. CODE : 2009 INTERNATIONAL WILDLAND URBAN INTERFACE CODE

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.