ASTM E 2121 : 2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Standard Practice for Installing Radon Mitigation Systems in Existing Low-Rise Residential Buildings
Hardcopy , PDF
11-11-2021
English
03-28-2013
Committee |
E 06
|
DocumentType |
Standard Practice
|
Pages |
13
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
1.1This practice describes methods for reducing radon entry into existing attached and detached residential buildings three stories or less in height. This practice is intended for use by trained, certified or licensed, or both, or otherwise qualified individuals.
1.2These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed information is contained in references cited throughout this practice.
1.3This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems.
1.4The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s) or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy, and for up to one year after occupancy, are covered by Guide E1465.
1.5This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions, to fulfill objectives of their specific radon contractor certification or licensure programs. Radon mitigation performed in accordance with this practice is considered ordinary repair.
1.6The methods addressed in this practice include the following categories of contractor activity: general practices, building investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation.
1.7The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.8This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety hazards.
ASTM E 2435 : 2005 : R2015 | Standard Guide for Application of Engineering Controls to Facilitate Use or Redevelopment of Chemical-Affected Properties |
ASTM E 2435 : 2005 : R2020 | Standard Guide for Application of Engineering Controls to Facilitate Use or Redevelopment of Chemical-Affected Properties |
ASTM D 7297 : 2021 | Standard Practice for Evaluating Residential Indoor Air Quality Concerns |
ASTM E 1745 : 2011 | Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM E 1465 : 1992 | Guide for Radon Control Options for the Design and Construction of New Low Rise Residential Buildings (Withdrawn 2001) |
ASTM E 1465 : 2008 | Standard Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings |
ASTM E 1745 : 2009 | Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM E 1465 : 2006 | Standard Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings |
ASTM E 1465 : 2007 | Standard Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings |
ASTM E 1465 : 2008 : REV A | Standard Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings (Withdrawn 2017) |
ASTM E 1745 : 2017 | Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM E 1745 : 1997 | Standard Specification for Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs |
ASTM E 1465 : 2007 : REV A | Standard Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings |