API 689 : 2007
Withdrawn
COLLECTION AND EXCHANGE OF RELIABILITY AND MAINTENANCE DATA FOR EQUIPMENT
English
07-01-2007
02-12-2025
API Foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Application
5.1 Equipment coverage
5.2 Time periods
5.3 Users of this International Standard
5.4 Limitations
5.5 Exchange of RM data
6 Benefits of RM data collection and exchange
7 Quality of data
7.1 Obtaining quality data
7.2 Data collection process
8 Equipment boundary, taxonomy and time definitions
8.1 Boundary description
8.2 Taxonomy
8.3 Timeline issues
9 Recommended data for equipment, failures and maintenance
9.1 Data categories
9.2 Data format
9.3 Database structure
9.4 Equipment data
9.5 Failure data
9.6 Maintenance data
Annex A (informative) - Equipment-class attributes
Annex B (normative) - Interpretation and notation of failure
and maintenance parameters
Annex C (informative) - Guide to interpretation and calculation
of derived reliability and maintenance parameters
Annex D (informative) - Typical requirements for data
Annex E (informative) - Key performance indicators (KPI[s]) and
benchmarking
Annex F (informative) - Classification and definition of
safety-critical failures
Bibliography
Provides a comprehensive basis for the collection of reliability and maintenance (RM) data in a standard format for equipment in all facilities and operations within the petroleum, natural gas and petrochemical industries during the operational life cycle of equipment.
| DevelopmentNote |
Also numbered as ISO 14224. (08/2007)
|
| DocumentType |
Standard
|
| Pages |
182
|
| PublisherName |
American Petroleum Institute
|
| Status |
Withdrawn
|
| API 691 : 2017 | RISK-BASED MACHINERY MANAGEMENT |
| ISO 15663-3:2001 | Petroleum and natural gas industries — Life-cycle costing — Part 3: Implementation guidelines |
| IEC 61025:2006 | Fault tree analysis (FTA) |
| ISO 15663-2:2001 | Petroleum and natural gas industries — Life-cycle costing — Part 2: Guidance on application of methodology and calculation methods |
| ISO 15663-1:2000 | Petroleum and natural gas industries — Life cycle costing — Part 1: Methodology |
| IEC 61123:1991 | Reliability testing - Compliance test plans for success ratio |
| IEC 60863:1986 | Presentation of reliability, maintainability and availability predictions |
| ISO 19900:2013 | Petroleum and natural gas industries — General requirements for offshore structures |
| IEC 60605-4:2001 | Equipment reliability testing - Part 4: Statistical procedures for exponential distribution - Point estimates, confidence intervals, prediction intervals and tolerance intervals |
| SAE JA1012_201108 | A Guide to the Reliability-Centered Maintenance (RCM) Standard |
| SAE JA1011_200908 | Evaluation Criteria for Reliability-Centered Maintenance (RCM) Processes |
| IEC 60319:1999 | Presentation and specification of reliability data for electronic components |
| IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| IEC 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
| IEC 61649:2008 | Weibull analysis |
| IEC 60300-3-12:2011 | Dependability management - Part 3-12: Application guide - Integrated logistic support |
| IEC 60300-3-4:2007 | Dependability management - Part 3-4: Application guide - Guide to the specification of dependability requirements |
| IEC 60605-6:2007 | Equipment reliability testing - Part 6: Tests for the validity and estimation of the constant failure rate and constant failure intensity |
| IEC 60706-3:2006 | Maintainability of equipment - Part 3: Verification and collection, analysis and presentation of data |
| IEC 61070:1991 | Compliance test procedures for steady-state availability |
| IEC 61078:2016 | Reliability block diagrams |
| IEC 61165:2006 | Application of Markov techniques |
| ISO 17776:2016 | Petroleum and natural gas industries — Offshore production installations — Major accident hazard management during the design of new installations |
| API 580 : 2016 | RISK-BASED INSPECTION |
| IEC 60300-3-2:2004 | Dependability management - Part 3-2: Application guide - Collection of dependability data from the field |
| IEC 61124:2012 | Reliability testing - Compliance tests for constant failure rate and constant failure intensity |
| IEC 62114:2001 | Electrical Insulation Systems - Thermal classification |
| BS 4778-3.1:1991 | Quality vocabulary. Availability, reliability and maintainability terms Guide to concepts and related definitions |
| IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
| IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 61164:2004 | Reliability growth - Statistical test and estimation methods |
| IEC 61703:2016 | Mathematical expressions for reliability, availability, maintainability and maintenance support terms |
| IEC 60076-1:2011 | Power transformers - Part 1: General |
| IEC 60300-1:2014 | Dependability management - Part 1: Guidance for management and application |
| ISO 14001:2015 | Environmental management systems — Requirements with guidance for use |
| IEC 60300-3-7:1999 | Dependability management - Part 3-7: Application guide - Reliability stress screening of electronic hardware |
| IEC 60706-1:1982 | Guide on maintainability of equipment. Part 1 - Sections One, Two and Three. Introduction, requirements and maintainability programme |
| IEC 60300-3-11:2009 | Dependability management - Part 3-11: Application guide - Reliability centred maintenance |
| IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
| API RP 14B : 2015 | DESIGN, INSTALLATION, OPERATION, TEST, AND REDRESS OF SUBSURFACE SAFETY VALVE SYSTEMS |
| IEC 60706-2:2006 | Maintainability of equipment - Part 2: Maintainability requirements and studies during the design and development phase |
| IEC 60300-2:2004 | Dependability management - Part 2: Guidelines for dependability management |
| IEC 60300-3-9:1995 | Dependability management - Part 3: Application guide - Section 9: Risk analysis of technological systems |
| IEC 60300-3-10:2001 | Dependability management - Part 3-10: Application guide - Maintainability |
| IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
| IEC 60706-5:2007 | Maintainability of equipment - Part 5: Testability and diagnostic testing |
| IEC 60381-2:1978 | Analogue signals for process control systems. Part 2: Direct voltage signals |
| MIL-STD-1629 Revision A:1980 | PROCEDURES FOR PERFORMING A FAILURE MODE, EFFECTS AND CRITICALITY ANALYSIS (NO S/S DOCUMENT) |
| IEC 61650:1997 | Reliability data analysis techniques - Procedures for comparison of two constant failure rates and two constant failure (event) intensities |
| IEC 60706-6:1994 | Guide on maintainability of equipment - Part 6: Section 9: Statistical methods in maintainability evaluation |
| IEC 60300-3-6:1997 | Dependability management - Part 3: Application guide - Section 6: Software aspects of dependability |
| IEC 60706-4:1992 | Guide on maintainability of equipment - Part 4 - Section 8: Maintenance and maintenance support planning |
| IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
| ISO 5208:2015 | Industrial valves — Pressure testing of metallic valves |