Einleitung
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen
4 Manuell aktivierte Auslösegeräte
5 Prüfungen von manuell aktivierten Auslösegeräten
6 Automatisch aktivierte Auslösegeräte
7 Kennzeichnung
Anhang A (normativ) Messungen der Kontakt- und
         Isolationswiderstände für mechanische
         Kontaktfunktionen
Anhang B (normativ) Spannvorrichtung für die Prüfung der
         Zugentlastung
Anhang C (normativ) Prüfaufbau, wenn HF-geschirmte
         Prüfeinrichtungen eingesetzt werden

Diese Norm legt die Anforderungen und Prüfungen für manuell aktivierte Auslösegeräte fest, die Teile einer Personen-Hilferufanlage sind. Diese Norm bezieht sich nur auf manuell aktivierte Auslösegeräte, die das Alarmauslösesignal an eine Örtliche Zentrale oder ein Übertragungsgerät drahtgebunden oder drahtlos mittels Funkübertragung übermittelt, d. h. a) ortsfest ausgeführter Druckknopf; b) ortsfest ausgeführter Zugschalter; c) tragbar ausgeführter Druckknopf; d) tragbar ausgeführter Zugschalter. Diese Norm gibt auch Hinweise auf automatisch aktivierte Auslösegeräte. Für auf solche Auslösegeräte anwendbaren Anforderungen und Prüfungen sind Verweise auf die einschlägigen CEN/CENELEC-Normen für Geräte für Brandmeldeanlagen, Gaswarn- und Einbruchmeldeanlagen gegeben. Diese Norm legt keine Anforderungen an EMV- Störungsaussendungen/Störstrahlung oder die elektrische Sicherheit fest. Diese sind durch andere Normen abgedeckt.

DevelopmentNote
Supersedes VDE 0830-4-2-1. (10/2001) DRAFT 2016 issued in September 2016. (09/2016)
DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
DIN EN 50134-2 : 2000 Identical
DIN EN 50134-2 : 2000 Corresponds
EN 50134-2:2017 Identical

16/30339543 DC : 0 BS EN 62820-3-2 ED 1.0 - BUILDING INTERCOM SYSTEMS - PART 3-2: APPLICATION GUIDELINES - ADVANCED SECURITY BUILDING INTERCOM

EN 50058:1998 Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % (v/v) gas
DIN IEC 61020-5-1:1994-02 Electromechanical switches for use in electronic equipment; part 5: sectional specification for pushbutton switches; section 1: blank detail specification; identical with IEC 61020-5-1:1991
VDE 0830-1-4 : 2015-04 Alarm systems Part 4: Electromagnetic compatibility – Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems;
EN 50054:1998 Electrical apparatus for the detection and measurement of combustible gases - General requirements and test methods
IEC 60341-1:1970 Push-button switches - Part 1: General requirements and measuring methods
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 50055:1998 Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 5 % (v/v) methane in air
EN 50057:1998 Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group II apparatus indicating up to 100 % lower explosive limit
VDE 0830-1-5 : 2012
DIN EN 60068-1 : 2015 ENVIRONMENTAL TESTING - PART 1: GENERAL AND GUIDANCE (IEC 60068-1:2013)
DIN EN 50130-4 : 2015-04 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 300 220-2 : 2.4.1 SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1 000 MHZ - PART 2: HARMONISED STANDARD FOR ACCESS TO RADIO SPECTRUM FOR NON SPECIFIC RADIO EQUIPMENT
DIN EN 50130-5 : 2012 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 50056:1998 Electrical apparatus for the detection and measurement of combustible gases - Performance requirements for Group I apparatus indicating up to 100 % (v/v) methane in air
DIN EN 300220-2:2017-05 SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ - PART 2: HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE DIRECTIVE 2014/53/EU FOR NON SPECIFIC RADIO EQUIPMENT
EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
DIN IEC 61020-5:1994-02 Electromechanical switches for use in electronic equipment; part 5: sectional specification for pushbutton switches; identical with IEC 61020-5:1991

Access your standards online with a subscription