• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

VDE 0281-3 : 2001 AMD 2 2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING

Superseded date

01-01-2012

Superseded by

VDE 0285-525-2-31 : 2012

Published date

12-01-2013

Sorry this product is not available in your region.

1 Anwendungsbereich
2 Aderleitung mit ein- oder mehrdrähtigem Leiter für
  allgemeine Anwendungen
  2.1 Bauartkurzzeichen
  2.2 Nennspannung
  2.3 Aufbau
  2.4 Prüfungen
  2.5 Hinweise für die Verwendung
3 Aderleitung mit feindrähtigem Leiter für allgemeine
  Anwendungen
  3.1 Bauartkurzzeichen
  3.2 Nennspannung
  3.3 Aufbau
  3.4 Prüfungen
  3.5 Hinweise für die Verwendung
4 Verdrahtungsleitung mit ein- und mehrdrähtigem Leiter
  für innere Verdrahtung
  4.1 Bauartkurzzeichen
  4.2 Nennspannung
  4.3 Aufbau
  4.4 Prüfungen
  4.5 Hinweise für die Verwendung
5 Verdrahtungsleitung mit feindrähtigem Leiter für
  innere Verdrahtung
  5.1 Bauartkurzzeichen
  5.2 Nennspannung
  5.3 Aufbau
  5.4 Prüfungen
  5.5 Hinweise für die Verwendung

Dieser Teil (Teil 3) des HD enthält die besonderen Bestimmungen für PVC-isolierte, einadrige, nicht-ummantelte Leitungen für die feste Verlegung mit Nennspannungen bis zu 450/750 V. Alle Leitungen müssen mit den entsprechenden Anforderungen des Teiles 1 und die einzelnen Bauarten der Leitungen mit den besonderen Anforderungen in diesem Teil 3 übereinstimmen. ANMERKUNG Die Aussenmasse der Leitungen nach diesem Teil des HD 21 sind in Übereinstimmung mit EN 60719 berechnet worden.

DocumentType
Standard
PublisherName
Verband Deutscher Elektrotechniker
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
HD 21-3 : S3 AMD 2 2008 Identical
IEC 60227-3:1993+AMD1:1997 CSV Identical
DIN VDE 0281-3 : 2001 AMD 2 2009 Identical

DIN EN 81-2:2000-05 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
VDE 0118-2 : 2010 ERRICHTEN ELEKTRISCHER ANLAGEN IM BERGBAU UNTER TAGE - TEIL 2: ZUSATZFESTLEGUNGEN
VDE 0711-202 : 97 AMD 1 97 LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS; SECTION 2: RECESSED LUMINAIRES
VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE
DIN EN 81-2:2010-08 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
DIN EN 81-1:2000-05 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 1: ELECTRIC LIFTS
DIN EN 81-1:2010-06 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 1: ELECTRIC LIFTS
DIN EN 115:1998-12 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF ESCALATORS AND PASSENGER CONVEYORS

DIN EN 60811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
VDE 0281-11 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES POUR LUMINAIRES
DIN EN 60811-1-2 : 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
VDE 0473-811-1-2 : 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
DIN VDE 0281-13 : 2003 POLYVINYL CHLORIDE INSULATED CABLES FOR RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 13: OIL RESISTANT PVC SHEATHED CABLES WITH TWO OR MORE CONDUCTORS
VDE 0281-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
VDE 0473-811-3-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE, TEST FOR RESISTANCE TO CRACKING
VDE 0473-811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION; SECTION 4: TEST AT LOW TEMPERATURE
VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 7: SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREES C
DIN VDE 0298-300 : 2009 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
VDE 0281-12 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR
DIN VDE 0281-10 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 10: EXTENSIBLE LEADS
DIN VDE 0281-11 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 11: CABLES FOR LUMINARIES
DIN EN 60811-3-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3-1: METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE, TEST FOR RESISTANCE TO CRACKING
DIN VDE 0295 : 1992 CONDUCTORS OF CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION
DIN EN 60811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TEST FOR DETERMINING THE MECHANICAL PROPERTIES
VDE 0295 : 2005 Conductors of insulated cables (IEC 60228:2004); German version EN 60228:2005 + Corrigendum:2005
DIN VDE 0281-12 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 12: HEAT-RESISTANT FLEXIBLE CABLES (CORDS)
VDE 0298-300 : 2009 LEITFADEN FUER DIE VERWENDUNG HARMONISIERTER NIEDERSPANNUNGSSTARKSTROMLEITUNGEN
DIN VDE 0281-7 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE
DIN VDE 0281-5 : 2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - FLEXIBLE CABLES (CORDS)
DIN VDE 0281-2 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 2: TEST METHODS
VDE 0482-265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
VDE 0281-2 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 2: TEST METHODS
VDE 0473-811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION; MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS; TEST FOR DETERMINING THE MECHANICAL PROPERTIES
VDE 0473-811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST, THERMAL STABILITY TEST
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
DIN EN 60811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
DIN VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF NOMINAL VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
DIN EN 60719 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
DIN VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
DIN EN 50265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
VDE 0281-10 : 2003 POLYVINYLCHLORID-ISOLIERTE STARKSTROMLEITUNGEN MIT NENNSPANNUNGEN BIS 450/750 V WENDELLEITUNGEN
VDE 0281-5 : 2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 5: FLEXIBLE CABLES AND CORDS
DIN VDE 0281-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
VDE 0281-13 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - PARTIE 13: CABLES SOUPLES AVEC GAINE DE POLYCHLORURE DE VINYLE, RESISTANT A L'HUILE, A DEUX AMES OU PLUS
VDE 0299-2 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.