• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

UNI EN ISO 16911-2 : 2013

Current

Current

The latest, up-to-date edition.

STATIONARY SOURCE EMISSIONS - MANUAL AND AUTOMATIC DETERMINATION OF VELOCITY AND VOLUME FLOW RATE IN DUCTS - PART 2: AUTOMATED MEASURING SYSTEMS

Published date

16-05-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Principle
6 Type testing, quality assurance level 1 data
7 Selection of automated measuring system location
8 Pre-investigation of flow profile
9 Calibration and validation of the automated measuring
   system (quality assurance level 2 and annual
   surveillance test)
10 Commissioning documentation
11 On-going quality assurance during operation (quality
   assurance level 3)
12 Assessment of uncertainty in volume flow rate
Annex A (informative) - Example of calculation of the
        calibration function (data from tests in
        Copenhagen and Wilhelmshaven)
Annex B (informative) - Flow profile characteristics
Annex C (informative) - Determination of measuring points
        and/or paths
Annex D (normative) - Treatment of a polynomial calibration
        function
Annex E (normative) - Values of k[v](N) and t[0,95(N - 1)]
Annex F (informative) - Example of a pre-investigation
        measurement
Annex G (informative) - Computational fluid dynamics issues
Annex H (informative) - The use of time of flight measurement
        instruments based on modulated laser light
Annex I (informative) - Relationship between this International
        Standard and the essential requirements of
        EU Directives
Bibliography

Defines specific requirements for automated measuring system (AMS) flow monitoring.

Committee
CT 4
DevelopmentNote
Together with UNI EN ISO 16911-1, supersedes UNI 10169. (05/2013)
DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current
Supersedes

Standards Relationship
ISO 16911-2:2013 Identical
EN ISO 16911-2:2013 Identical

EN 15267-3:2007 Air quality - Certification of automated measuring systems - Part 3: Performance criteria and test procedures for automated measuring systems for monitoring emissions from stationary sources
CEN/TR 15983:2010 Stationary source emissions - Guidance on the application of EN 14181:2004
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 16911-1:2013 Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method (ISO 16911-1:2013)
EN 15259:2007 Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
EN 14181:2014 Stationary source emissions - Quality assurance of automated measuring systems

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.