PRECAST CONCRETE PRODUCTS - NORMAL WEIGHT AND LIGHTWEIGHT CONCRETE SHUTTERING BLOCKS - PRODUCT PROPERTIES AND PERFORMANCE

Published date

11-09-2008

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
  3.1 Terms and definitions
  3.2 Symbols
4 Requirements
  4.1 General
  4.2 Raw materials and concrete
  4.3 Dangerous substances
  4.4 Geometric properties
  4.5 Density
  4.6 Moisture movement
  4.7 Reaction to fire
  4.8 Water vapour permeability
  4.9 Mechanical strength
  4.10 Acoustic properties
  4.11 Thermal properties
  4.12 Water absorption by capillarity
  4.13 Durability
5 Test methods
  5.1 Geometric properties
  5.2 Density
  5.3 Mechanical strength
6 Classification
7 Marking
8 Evaluation of conformity
  8.1 General
  8.2 Initial type testing
  8.3 Factory production control
Annex A (normative) - Determination of web tensile strength
      A.1 Principle
      A.2 Apparatus
      A.3 Procedure
      A.4 Determining the tensile strength of webs
      A.5 Test report
Annex B (normative) - Determination of shell flexural strength
      B.1 Principle
      B.2 Apparatus
      B.3 Procedure
      B.4 Determining the flexural strength of the shells
      B.5 Test report
Annex C (normative) - Sampling for initial type testing
      C.1 General
      C.2 Sampling procedure
      C.3 Place and dates of inspection and acceptance testing
Annex D (normative) - Compliance criteria for initial type
        testing and for independent batch acceptance testing
Annex E (informative) - Example of inspection schemes
      E.1 Equipment inspection
      E.2 Materials inspection
      E.3 Production process inspection
      E.4 Product inspection
      E.5 Switching rules
Annex F (informative) - Filling pressure of concrete infill
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Directive
      ZA.1 Scope and relevant characteristics
      ZA.2 Procedure for attestation of conformity of concrete
           shuttering blocks
      ZA.3 CE marking and labelling
Bibliography

Describes the properties, performance and test methods of factory made, non-load bearing hollow concrete shuttering blocks made from normal weight or lightweight aggregates or a combination of both.

Committee
CT 21
DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current

Standards Relationship
EN 15435:2008 Identical

EN 772-1:2011+A1:2015 Methods of test for masonry units - Part 1: Determination of compressive strength
EN 12390-5:2009 Testing hardened concrete - Part 5: Flexural strength of test specimens
EN 1745:2012 Masonry and masonry products - Methods for determining thermal properties
EN 1008:2002 Mixing water for concrete - Specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete
ISO 12572:2016 Hygrothermal performance of building materials and products Determination of water vapour transmission properties Cup method
EN 772-14:2001 Methods of test for masonry units - Part 14: Determination of moisture movement of aggregate concrete and manufactured stone masonry units
EN 772-16:2011 Methods of test for masonry units - Part 16: Determination of dimensions
EN ISO 12572:2016 Hygrothermal performance of building materials and products - Determination of water vapour transmission properties - Cup method (ISO 12572:2016)
EN 12664:2001 Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Dry and moist products of medium and low thermal resistance
EN 772-11:2011 Methods of test for masonry units - Part 11: Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.