STATIC THERMOPLASTIC TANKS FOR THE ABOVE GROUND STORAGE OF CHEMICALS - BLOW MOULDED OR ROTATIONALLY MOULDED POLYETHYLENE TANKS - REQUIREMENTS AND TEST METHODS
14-06-2012
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for materials
5 Design requirements
6 Requirements for tanks
7 Marking, transport, handling and installation of tanks
Annex A (informative) - Creep curves
Annex B (normative) - Test methods for determination of
material characteristics
Annex C (normative) - Test methods for determination of
tank characteristics
Annex D (informative) - Evaluation of conformity
Annex E (informative) - A-deviations
Bibliography
Defines requirements for materials, physical properties and performance for blow moulded and rotationally moulded polyethylene single tanks, with or without reinforcement, for the above ground storage of chemical liquids having a maximum specific gravity of 1400 kg/m[3] except water and those liquids dealt with by EN 13341.
DocumentType |
Test Method
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Current
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN 13575:2012 | Identical |
NF EN 13575 : 2012 | Identical |
NEN EN 13575 : 2012 | Identical |
SN EN 13575:2012 | Identical |
EN 13575:2012 | Identical |
I.S. EN 13575:2012 | Identical |
BS EN 13575:2012 | Identical |
DIN EN 13575:2012-06 | Identical |
NBN EN 13575 : 2012 | Identical |
NS EN 13575 : 2012 | Identical |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
ISO 293:2004 | Plastics — Compression moulding of test specimens of thermoplastic materials |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
EN ISO 527-2:2012 | Plastics - Determination of tensile properties - Part 2: Test conditions for moulding and extrusion plastics (ISO 527-2:2012) |
ISO 11357-5:2013 | Plastics — Differential scanning calorimetry (DSC) — Part 5: Determination of characteristic reaction-curve temperatures and times, enthalpy of reaction and degree of conversion |
ISO 23667:2007 | Packaging Transport packaging for dangerous goods Rigid plastics and plastics composite IBCs Compatibility testing |
EN 13341:2005+A1:2011 | Static thermoplastic tanks for above ground storage of domestic heating oils, kerosene and diesel fuels - Blow moulded and rotationally moulded polyethylene tanks and rotationally moulded tanks made of anionically polymerized polyamide 6 - Requirements and test methods |
EN ISO 179-1:2010 | Plastics - Determination of Charpy impact properties - Part 1: Non-instrumented impact test (ISO 179-1:2010) |
ISO 527-2:2012 | Plastics — Determination of tensile properties — Part 2: Test conditions for moulding and extrusion plastics |
EN ISO 293:2005 | Plastics - Compression moulding of test specimens of thermoplastic materials (ISO 293:2004) |
EN ISO 23667:2007 | Packaging - Transport packaging for dangerous goods - Rigid plastics and plastics composite IBCs - Compatibility testing (ISO 23667:2007) |
EN 1778:1999 | Characteristic values for welded thermoplastics constructions - Determination of allowable stresses and moduli for design of thermoplastics equipment |
ISO 1183-1:2012 | Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method |
ISO 1872-2:2007 | Plastics Polyethylene (PE) moulding and extrusion materials Part 2: Preparation of test specimens and determination of properties |
ISO 1183-2:2004 | Plastics Methods for determining the density of non-cellular plastics Part 2: Density gradient column method |
EN 10204:2004 | Metallic products - Types of inspection documents |
ISO 179-1:2010 | Plastics — Determination of Charpy impact properties — Part 1: Non-instrumented impact test |
ISO 11357-6:2008 | Plastics Differential scanning calorimetry (DSC) Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
EN ISO 1872-2:2007 | Plastics - Polyethylene (PE) moulding and extrusion materials - Part 2: Preparation of test specimens and determination of properties (ISO 1872-2:2007) |
EN ISO 1133:2005 | Plastics - Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics (ISO 1133:2005) |
EN ISO 4892-2:2013 | Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2:2013) |
ISO 1133:2005 | Plastics Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics |
EN ISO 1183-1:2012 | Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012) |
CLC/TR 50404:2003 | Electrostatics - Code of practice for the avoidance of hazards due to static electricity |
EN ISO 1183-2:2004 | Plastics - Methods for determining the density of non-cellular plastics - Part 2: Density gradient column method (ISO 1183-2:2004) |