• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

UNI CEN/TS 14383-3 : 2006

Current

Current

The latest, up-to-date edition.

PREVENTION OF CRIME - URBAN PLANNING AND BUILDING DESIGN - PART 3: DWELLINGS

Published date

16-02-2006

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Objectives and methodology
5 Risk analysis and assessment of related protection levels
6 Level of protection
7 Individual dwellings
8 The building envelope
9 Residential blocks
10 Enhancing security in residential blocks
11 Apartments
12 Management and maintenance of residential blocks
Annex A (informative) - Resistance classes for windows,
   doors and shutters and requirements for related hardware
   conforming to ENV 1627
Annex B (informative) - Risk analysis of the vulnerability
   of dwellings to burglary
Annex C (informative) - Quick reference guide to the
   vulnerability of dwellings to burglary
Annex D (informative) - Security grades of intrusion alarm
   systems as EN 50131-1
Annex E (informative) - Indicators of security problems in
   residential areas
Annex F (informative) - Cost/benefit checklist of methods
   to enhance security in residential blocks
Bibliography

Provides guidance and recommendations for reducing the risk of crimes against people and property in dwellings and their immediate surroundings through planning and design.

Committee
CT 33
DocumentType
Technical Specification
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current

Standards Relationship
CEN/TS 14383-3:2005 Identical

ENV 1630:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
EN 1906:2012 Building hardware - Lever handles and knob furniture - Requirements and test methods
EN 13123-2:2004 Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test
ENV 1629:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading
EN 1303:2015 Building hardware - Cylinders for locks - Requirements and test methods
EN 1143-1:2012 Secure storage units - Requirements, classification and methods of test for resistance to burglary - Part 1: Safes, ATM safes, strongroom doors and strongrooms
EN 13541:2012 Glass in building - Security glazing - Testing and classification of resistance against explosion pressure
EN 10223-6:2012 Steel wire and wire products for fencing and netting - Part 6: Steel wire chain link fencing
EN 81-1:1998+A3:2009 Safety rules for the construction and installation of lifts - Part 1: Electric lifts
ENV 14383-2:2003 Prevention of crime - Urban planning and design - Part 2: Urban planning
EN 12839:2012 Precast concrete products - Elements for fences
EN 12209:2016 Building hardware - Mechanically operated locks and locking plates - Requirements and test methods
EN 1176-1:2017 Playground equipment and surfacing - Part 1: General safety requirements and test methods
EN 13123-1:2001 Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube
IEC 60598-2-3:2002+AMD1:2011 CSV Luminaires - Part 2-3: Particular requirements - Luminaires for road and street lighting
PREN 13637 : DRAFT 2014 BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS
EN 1063:1999 Glass in building - Security glazing - Testing and classification of resistance against bullet attack
ENV 1628:1999 Windows, doors, shutters - Burglar resistance - Test method for the determination of resistance under static loading
ENV 1627:1999 Windows, doors, shutters - Burglar resistance - Requirements and classification
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 356:1999 Glass in building - Security glazing - Testing and classification of resistance against manual attack
EN 1522:1998 Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification
EN 60598-2-3:2003/A1:2011 LUMINAIRES - PART 2-3: PARTICULAR REQUIREMENTS - LUMINAIRES FOR ROAD AND STREET LIGHTING (IEC 60598-2-3:2002/A1:2011)
EN 50132-7:2012 Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines
EN 14600:2005 Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
EN 50133-1 : 1996 AMD 1 2002 ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS
EN 179:2008 Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.