UNE-EN ISO 15197:2015

Current

Current

The latest, up-to-date edition.

In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013)

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

23-09-2015

£102.69
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Design and development
  4.1 General requirements
  4.2 Safety
  4.3 Traceability
  4.4 Ergonomic/human factor aspects
  4.5 Risk analysis
  4.6 User verification
5 Information supplied by the manufacturer
  5.1 Labels for the blood-glucose meter
  5.2 Instructions for use for the blood-glucose monitoring
       system
  5.3 Labels for the reagent system and control material
  5.4 Instructions for use for reagents and control material
6 Safety and reliability testing
  6.1 General requirements
  6.2 Protection against electric shock
  6.3 Protection against mechanical hazards
  6.4 Electromagnetic compatibility
  6.5 Resistance to heat
  6.6 Resistance to moisture and liquids
  6.7 Protection against liberated gases, explosion and
       implosion
  6.8 Meter components
  6.9 Performance test
  6.10 Mechanical resistance to shock, vibration and impact
  6.11 Equipment temperature exposure limits
  6.12 Equipment humidity exposure test protocol
  6.13 Reagent storage and use testing
7 Analytical performance evaluation
  7.1 General requirements
  7.2 Precision evaluation
  7.3 System accuracy evaluation
  7.4 Minimum acceptable system accuracy
8 User performance evaluation
  8.1 General
  8.2 Evaluation sites
  8.3 User evaluation
  8.4 Evaluation for instructions for use
Annex A (normative) Additional requirements for electromagnetic
        compatibility
Annex B (informative) Traceability chain
Bibliography

Gives requirements for in vitro glucose monitoring systems that measure glucose concentrations in capillary blood samples and procedures for the verification and the validation of performance by the intended users.

Committee
CTN 129
DocumentType
Standard
Pages
60
PublisherName
Asociacion Espanola de Normalizacion
Status
Current
Supersedes

ISO 5725-1:1994 Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions
IEC 61326-2-6:2012 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment
EN ISO 18113-1:2011 In vitro diagnostic medical devices - Information supplied by the manufacturer (labelling) - Part 1: Terms, definitions and general requirements (ISO 18113-1:2009)
ISO 18113-1:2009 In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 1: Terms, definitions and general requirements
EN 61326-2-6:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical equipment
CLSI EP5 A2 : 2ED 2004 EVALUATION OF PRECISION PERFORMANCE OF QUANTITATIVE MEASUREMENT METHODS
ISO 13485:2016 Medical devices Quality management systems Requirements for regulatory purposes
EN 60068-2-64:2008 ENVIRONMENTAL TESTING - PART 2-64: TESTS - TEST FH: VIBRATION, BROADBAND RANDOM AND GUIDANCE
ISO 18113-4:2009 In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 4: In vitro diagnostic reagents for self-testing
ISO 5725-3:1994 Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method
IEC 60068-2-64:2008 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 62366:2007+AMD1:2014 CSV Medical devices - Application of usability engineering to medical devices
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
ISO 23640:2011 In vitro diagnostic medical devices — Evaluation of stability of in vitro diagnostic reagents
ISO 17511:2003 In vitro diagnostic medical devices Measurement of quantities in biological samples Metrological traceability of values assigned to calibrators and control materials
EN ISO 23640:2015 In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents (ISO 23640:2011)
EN 62366 : 2008 AMD 1 2015 MEDICAL DEVICES - APPLICATION OF USABILITY ENGINEERING TO MEDICAL DEVICES (IEC 62366:2007/A1:2014)
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
CLSI C53 P : 1ED 2008 CHARACTERIZATION AND QUALIFICATION OF COMMUTABLE REFERENCE MATERIALS FOR LABORATORY MEDICINE
EN ISO 14971:2012 Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01)
EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
ISO 14971:2007 Medical devices Application of risk management to medical devices
ISO 18113-5:2009 In vitro diagnostic medical devices — Information supplied by the manufacturer (labelling) — Part 5: In vitro diagnostic instruments for self-testing
EN ISO 18113-5:2011 In vitro diagnostic medical devices - Information supplied by the manufacturer (labelling) - Part 5: In vitro diagnostic instruments for self-testing (ISO 18113-5:2009)
EN 61010-2-101:2017 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
CLSI EP7 A2 : 2ED 2005 INTERFERENCE TESTING IN CLINICAL CHEMISTRY
IEC 61010-1:2010+AMD1:2016 CSV Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
CLSI EP9 A2 : 2ED 2002 METHOD COMPARISON AND BIAS ESTIMATION USING PATIENT SAMPLES
EN ISO 17511:2003 In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials (ISO 17511:2003)