UNE-EN 62271-201:2015
Current
The latest, up-to-date edition.
High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
Hardcopy , PDF
Spanish, Castilian, English
29-07-2015
1 General
1.1 Scope
1.2 Normative references
2 Normal and special service conditions
3 Terms and definitions
4 Ratings
4.1 Rated voltage (U[r])
4.2 Rated insulation level
4.3 Rated frequency (f[r])
4.4 Rated normal current and temperature rise
4.5 Rated short-time withstand current (I[k])
4.6 Rated peak withstand current (I[p])
4.7 Rated duration of short circuit (t[k])
4.8 Rated supply voltage of closing and opening devices
and of auxiliary and control circuits (U[a])
4.9 Rated supply frequency of operating devices and of
auxiliary and control circuits
4.10 Rated pressure of compressed gas supply for insulation
and/or operation
5 Design and construction
5.1 Requirements for liquids in switchgear and controlgear
5.2 Requirements for gases in switchgear and controlgear
5.3 Earthing of switchgear and controlgear
5.4 Auxiliary and control equipment
5.5 Dependent power closing
5.6 Stored energy closing
5.7 Independent manual operation
5.8 Operation of releases
5.9 Low- and high-pressure interlocking and monitoring devices
5.10 Nameplates
5.11 Interlocking devices
5.12 Position indication
5.13 Degrees of protection by enclosures
5.14 Creepage distances
5.15 Gas and vacuum tightness
5.16 Liquid tightness
5.17 Flammability
5.18 Electromagnetic compatibility (EMC)
5.101 Internal fault
5.102 Insulation enclosure
5.103 Compartments
5.104 Removable parts
5.105 Provisions for dielectric tests on cables
6 Type tests
6.1 General
6.2 Dielectric tests
6.3 Radio interference voltage (r.i.v.) test
6.4 Measurement of the resistance of circuits
6.5 Temperature-rise tests
6.6 Short-time withstand current and peak withstand current
tests
6.7 Verification of the protection
6.8 Tightness tests
6.9 Electromagnetic compatibility tests (EMC)
6.10 Additional tests on auxiliary and control circuits
6.101 Verification of making and breaking capacities
6.102 Mechanical operation tests
6.103 Pressure withstand test for gas-filled compartments
6.104 Tests to prove the protection of persons against
electric shock
6.105 Internal arcing test
6.106 Thermal stability test
6.107 Humidity test
7 Routine tests
7.1 Dielectric tests on the main circuit
7.2 Tests on auxiliary and control circuits
7.3 Measurement of the resistance of the main circuit
7.4 Tightness test
7.5 Design and visual checks
7.101 Partial discharge measurement
7.102 Mechanical operation tests
7.103 Pressure tests of gas-filled compartments
7.104 Tests of auxiliary electrical, pneumatic and hydraulic
devices
7.105 Tests after erection on site
7.106 Measurement of fluid condition after filling on site
8 Guide to the selection of insulation-enclosed switchgear and
controlgear for service
8.1 Selection of rated values
8.2 Selection of design and construction
8.3 Internal arc classification
9 Information to be given with enquiries, tenders and orders
9.101 Information to be given with enquiries and orders
9.102 Information to be given with tenders
10 Rules for transport, storage, erection and maintenance
10.1 Conditions during transport, storage and erection
10.2 Installation
10.3 Operation
10.4 Maintenance
11 Safety
11.101 Procedures
11.102 Internal arc aspects
12 Influence of the product on the environment
Annex A (normative) Internal fault - Method for testing the
insulation-enclosed switchgear and controlgear under
conditions of arcing due to an internal fault
Annex B (normative) Partial discharge measurement
Annex C (normative) Humidity test
Annex D (informative) Protection grades
Annex ZA (normative) Normative references to international
publications with their corresponding European
publications
Annex ZB (informative) A-deviations
Bibliography
Describes requirements for factory-assembled insulation-enclosed switchgear and controlgear for alternating current of rated voltages above 1 kV and up to and including 52 kV for indoor installation and for service frequencies up to and including 60 Hz.
Committee |
CTN 207/SC 17AC-32A
|
DocumentType |
Standard
|
Pages |
106
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN 62271-201:2014 | Identical |
IEC 62271-201:2014 | Identical |
NF EN 62271-201 : 2014 | Identical |
NBN EN 62271-201 : 2014 | Identical |
I.S. EN 62271-201:2014 | Identical |
DIN EN 62271-201 : 2015-03 | Identical |
EN 62271-201:2014 | Identical |
IEC 60243-1:2013 | Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies |
EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV | High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 62271-105:2012 | High-voltage switchgear and controlgear - Part 105: Alternating current switch-fuse combinations for rated voltages above 1 kV up to and including 52 kV |
EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
EN 62271-102:2002/AC:2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013) |
IEC 60909-0:2016 | Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents |
IEEE 400.2-2013 REDLINE | IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz) |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
EN 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC TS 62271-304:2008 | High-voltage switchgear and controlgear - Part 304: Design classes for indoor enclosed switchgear and controlgear for rated voltages above 1 kV up to and includuing 52 kV to be used in severe climatic conditions |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
EN 62271-106:2011 | High-voltage switchgear and controlgear - Part 106: Alternating current contactors, contactor-based controllers and motor-starters |
IEC 62271-103:2011 | High-voltage switchgear and controlgear - Part 103: Switches for rated voltages above 1 kV up to and including 52 kV |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEEE C37.20.7-2007 REDLINE | IEEE Guide for Testing Metal-Enclosed Switchgear Rated Up to 38 kV for Internal Arcing Faults |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
IEC 60059:1999+AMD1:2009 CSV | IEC standard current ratings |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
EN 62271-105:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 105: ALTERNATING CURRENT SWITCH-FUSE COMBINATIONS FOR RATED VOLTAGES ABOVE 1 KV UP TO AND INCLUDING 52 KV (IEC 62271-105:2012) |
EN 50187 : 96 AC 96 | GAS-FILLED COMPARTMENTS FOR A.C. SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 62271-102:2001+AMD1:2011+AMD2:2013 CSV | High-voltage switchgear and controlgear - Part 102: Alternatingcurrent disconnectors and earthing switches |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.