• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

UNE-EN 1364-4:2015

Current

Current

The latest, up-to-date edition.

Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

11-11-2015

£105.77
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Test equipment
   4.1 General testing principles
   4.2 Furnace configuration
   4.3 Supporting floor
5 Test conditions
6 Test specimen
   6.1 General
   6.2 Number of specimens
   6.3 Size of specimens
   6.4 Surfaces
   6.5 Design
       6.5.1 General
       6.5.2 Restraint of the specimen
   6.6 Construction
   6.7 Verification
7 Installation of test specimen
   7.1 General
   7.2 Supporting floor
       7.2.1 Standard supporting floor
       7.2.2 Non-standard supporting floor
       7.2.3 Furnace closure
   7.3 Fixing
8 Conditioning
9 Application of instrumentation
   9.1 Furnace thermocouples (plate thermometers)
       9.1.1 General
       9.1.2 Standard time temperature curve (internal exposure)
       9.1.3 External fire exposure curve
   9.2 Unexposed face thermocouples
       9.2.1 General
       9.2.2 Mean temperature rise
       9.2.3 Maximum temperature rise
   9.3 Thermocouples on fixings
   9.4 Pressure
   9.5 Deflection
   9.6 Radiation
10 Test procedure
11 Performance criteria
12 Test report
13 Field of direct application of test results
Annex A (informative) Guidance on testing curtain walling -
        part configuration
      A.1 Standard configuration
          A.1.1 General
          A.1.2 Supporting floor
          A.1.3 Parts of curtain walling system
          A.1.4 Specimen selection
      A.2 Test principles and requirements
      A.3 Fire from the inside
          A.3.1 General
          A.3.2 Non-fire-resistant glazing
          A.3.3 Fire-resistant glazing
      A.4 Fire from the outside
Annex B (normative) Standard configurations
      B.1 General
      B.2 Description of the standard configurations
Bibliography

This European Standard specifies a method for determining the fire resistance of parts of curtain walling and of the perimeter seal.

Committee
CTN 23
DevelopmentNote
Supersedes UNE 23801. (01/2012)
DocumentType
Standard
Pages
64
PublisherName
Asociacion Espanola de Normalizacion
Status
Current
Supersedes

Standards Relationship
NF EN 1364-4 : 2014 Identical
NBN EN 1364-4 : 2014 Identical
NEN EN 1364-4 : 2014 Identical
NS EN 1364-4 : 2014 Identical
I.S. EN 1364-4:2014 Identical
SN EN 1364-4 : 2014 Identical
UNI EN 1364-4 : 2014 Identical
BS EN 1364-4:2014 Identical
EN 1364-4:2014 Identical
DIN EN 1364-4:2014-05 Identical

EN 1364-3:2014 Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly)
EN 1364-1:1999 Fire resistance tests for non-loadbearing elements - Part 1: Walls
ISO 13943:2017 Fire safety — Vocabulary
EN 13501-2:2016 Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
EN 13830:2015 Curtain walling - Product standard
EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
EN 13119:2016 Curtain walling - Terminology
EN 1363-2:1999 Fire resistance tests - Part 2: Alternative and additional procedures

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.