UL 444:5ED 2017-01-20
Current
The latest, up-to-date edition.
Communications Cables
Hardcopy
20-01-2017
Preface
Communication Cables
1 Scope
2 Reference publications
3 Definitions
4 General Requirements
5 Construction
6 Manufacturing and Production Tests
7 Capability Tests
8 Marking of Cables
9 Marking on Tag, Reel, or Carton
10 Date of Manufacture
ANNEX A - Electrical codes for wire types
ANNEX B - Guidelines for sample selection for flame and
smoke test requirements
ANNEX C - Cable substitutions
This revision of ANSI/UL 444 dated June 16, 2021 includes the following changes in requirements: – Introduction of Optional Suffixes HF, LSHF and ST1; 8.3.3.1, 8.4.7 – 8.4.10 – Use of an Additional 14 AWG Conductor in a Multi-conductor Communications Cable; 5.2.1, 8.3.9.1, 9.1.9, Table 4 – Criteria for FT6 flame test classification; 7.14.1 – Delete Annex C – Cable substitution – Add a definition – Grounding/Bonding Conductor; 3.9A As noted in the Commitment for Amendments statement located on the back side of the title page, UL and CSA are committed to updating this harmonized standard jointly.
DevelopmentNote |
Also Numbered As CSA C22.2.214 (04/2002) NEW CHILD REV 2 2021 IS NOW ADDED.
|
DocumentType |
Standard
|
Pages |
0
|
ProductNote |
NEW CHILD REV 2 2021 IS NOW ADDED.
|
PublisherName |
Underwriters Laboratories
|
Status |
Current
|
1.1 This standard applies to 60 – 250°C single- or multiple-conductor jacketed or unjacketed, integral or nonintegral cables and single or multiple coaxial cables for telephone and other communication circuits such as voice, data, and audio for on-premise customer systems.
EN 62680-2-3:2015 | Universal Serial Bus interfaces for data and power - Part 2-3: Universal Serial Bus Cables and Connectors Class Document, Revision 2.0 (TA 14) |
NEMA WC 63.2:1996(R2003) | Performance Standard for Coaxial Premise Data Communications Cables |
CSA T568.2 : 2005 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED-PAIR CABLING COMPONENTS |
NFPA 76 : 2016 | FIRE PROTECTION OF TELECOMMUNICATIONS FACILITIES |
CSA T568.1 : 2005 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS |
IEEE 789-2013 | IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments |
BS EN 62680-2-3:2015 | Universal Serial Bus interfaces for data and power Universal Serial Bus Cables and Connectors Class Document Revision 2.0 (TA 14) |
UL 508A:3ED 2018-04-24 | Industrial Control Panels |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
I.S. EN 62680-4:2014 | UNIVERSAL SERIAL BUS INTERFACES FOR DATA AND POWER - PART 4: UNIVERSAL SERIAL BUS CABLES AND CONNECTORS CLASS DOCUMENT, REVISION 2.0 |
IEC 62680-4:2013 | Universal serial bus interfaces for data and power - Part 4: Universal Serial Bus Cables and Connectors Class Document, Revision 2.0 |
BS EN 62680-4:2014 | Universal serial bus interfaces for data and power Universal Serial Bus Cables and Connectors Class Document, Revision 2.0 |
UL 1424:4ED 2015-01-22 | Cables for Power-Limited Fire-Alarm Circuits |
IEC 62680-2-3:2015 | Universal serial bus interfaces for data and power - Part 2-3: Universal Serial Bus Cables and Connectors Class Document Revision 2.0 |
NFPA 301 : 2018 | SAFETY TO LIFE FROM FIRE ON MERCHANT VESSELS |
UL 343:9ED 2008-12-17 | Pumps for Oil-Burning Appliances |
NASA KSC E 165 : 2009 | ELECTRICAL GROUND SUPPORT EQUIPMENT FABRICATION, SPECIFICATION FOR |
UL 1690:4ED 2015-07-07 | Data-Processing Cable |
I.S. EN 62680-2-3:2015 | UNIVERSAL SERIAL BUS INTERFACES FOR DATA AND POWER - PART 2-3: UNIVERSAL SERIAL BUS CABLES AND CONNECTORS CLASS DOCUMENT, REVISION 2.0 (TA 14) |
CSA T568.2 : 2005 : R2010 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED-PAIR CABLING COMPONENTS |
EN 62680-4:2014 | Universal serial bus interfaces for data and power - Part 4: Universal Serial Bus Cables and Connectors Class Document, Revision 2.0 |
CSA T568.1 : 2005 : R2010 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 1: GENERAL REQUIREMENTS |
TIA 570 : C2012 | RESIDENTIAL TELECOMMUNICATIONS INFRASTRUCTURE STANDARD |
UL 1685:4ED 2015-07-07 | Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables |
NFPA 262 : 2015 | METHOD OF TEST FOR FLAME TRAVEL AND SMOKE OF WIRES AND CABLES FOR USE IN AIR-HANDLING SPACES |
ASTM D 5374 : 2013 : REDLINE | Standard Test Methods for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
UL 2196:2ED 2017-08-29 | Fire Test for Circuit Integrity of Fire-Resistive Power, Instrumentation, Control and Data Cables |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
UL 1666:5ED 2007-02-16 | Test for Flame Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts |
CSA C22.2 No. 2556 : 2015 | WIRE AND CABLE TEST METHODS |
ASTM D 5423 : 2014 | Standard Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.