UFC 3-410-01 : Change 4
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
UNIFIED FACILITIES CRITERIA - HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS
19-11-2022
21-09-2016
CHAPTER 1 - INTRODUCTION
CHAPTER 2 - MECHANICAL CONSENSUS STANDARDS
CHAPTER 3 - GENERAL DESIGN REQUIREMENTS
CHAPTER 4 - SUPPLEMENTAL IMC TECHNICAL CRITERIA
CHAPTER 5 - DESIGN ANALYSIS AND DRAWING REQUIREMENTS
APPENDIX A - REFERENCES
APPENDIX B - BEST PRACTICES
APPENDIX C - GLOSSARY
APPENDIX D - MINIMUM CONTROL POINTS LIST
APPENDIX E - HVAC SYSTEM SELECTION FLOW CHART
APPENDIX F - 90% ENERGY-EFFICIENT HVAC SOLUTIONS (FOR ARMY PROJECTS ONLY)
APPENDIX G - EVALUATION OF DISTRICT AND ISLANDED/DECENTRALIZED UTILITY OPTIONS WITH LIFE-CYCLE COST ANALYSIS GUIDANCE (FOR ARMY PROJECTS ONLY)
Gives requirements and guidance in the design of heating, ventilating, and air-conditioning (HVAC) systems, together with the criteria for selecting HVAC materials and equipment.
DocumentType |
Standard
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Superseded
|
SupersededBy |
FC 4-610-04F : 2015 | FACILITIES CRITERIA - AIR FORCE LEGAL FACILITIES |
FC 4-141-05N : 2015 | FACILITIES CRITERIA - NAVY AND MARINE CORPS INDUSTRIAL CONTROL SYSTEMS MONITORING STATIONS |
FC 1-300-09N : Change 3 | FACILITIES CRITERIA - NAVY AND MARINE CORPS DESIGN PROCEDURES |
UFC 3-540-08 : 2017 | UNIFIED FACILITIES CRITERIA - UTILITY-SCALE RENEWABLE ENERGY SYSTEMS |
FC 4-721-02F : 2015 | FACILITIES CRITERIA - AIR FORCE LEVEL 1 CONFINEMENT FACILITY |
FC 4-740-14N : 2014 | FACILITIES CRITERIA - NAVY AND MARINE CORPS CHILD DEVELOPMENT CENTERS |
FC 4-722-01N : 2013 | FACILITIES CRITERIA - NAVY AND MARINE CORPS DINING FACILITIES |
FC 4-218-01F : 2015 | FACILITIES CRITERIA - AIR FORCE CRITERIA FOR PRECISION MEASUREMENT EQUIPMENT LABORATORY DESIGN AND CONSTRUCTION |
UFC 4-211-02 : 2012 | UNIFIED FACILITIES CRITERIA - AIRCRAFT CORROSION CONTROL AND PAINT FACILITIES |
FC 4-171-06N : 2014 | FACILITIES CRITERIA - NAVY OPERATIONAL SUPPORT CENTER |
UFC 4-440-01 : 2014 | UNIFIED FACILITIES CRITERIA - WAREHOUSES AND STORAGE FACILITIES |
FC 4-740-02N : 2014 | FACILITIES CRITERIA - NAVY AND MARINE CORPS FITNESS CENTERS |
FC 4-730-10N : 2013 | FACILITIES CRITERIA - NAVY AND MARINE CORPS FIRE STATIONS |
UFC 4-211-01 : Change 1 | UNIFIED FACILITIES CRITERIA - AIRCRAFT MAINTENANCE HANGARS |
UFC 1-200-02 : Change 1 | UNIFIED FACILITIES CRITERIA - HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS |
FC 4-179-03F : 2015 | FACILITIES CRITERIA - AIR FORCE INDOOR SMALL ARMS FIRING RANGE |
UFC 3-401-01 : Change 1 | UNIFIED FACILITIES CRITERIA - MECHANICAL ENGINEERING |
UFC 3-520-05 : Change 1 | UNIFIED FACILITIES CRITERIA - STATIONARY BATTERY AREAS |
UL 268A:4ED 2008-12-11 | Smoke Detectors for Duct Application |
UFC 4-010-01 : 2018 | UNIFIED FACILITIES CRITERIA - DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS |
UFC 3-440-01 : V20020614 | UNIFIED FACILITIES CRITERIA - FACILITY-SCALE RENEWABLEENERGY SYSTEMS |
UFC 3-501-01 : 2015 | UNIFIED FACILITIES CRITERIA - ELECTRICAL ENGINEERING |
UFC 3-410-02 : Change 1 | UNIFIED FACILITIES CRITERIA - LONWORKS[R] DIRECT DIGITAL CONTROL FOR HVAC AND OTHER LOCAL BUILDING SYSTEMS |
NFPA 58 : 2017 | LIQUEFIED PETROLEUM GAS CODE |
FC 4-722-01N : 2013 | FACILITIES CRITERIA - NAVY AND MARINE CORPS DINING FACILITIES |
NFPA 96 : 2017 | VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS |
UFC 3-430-07 : Change 4 | UNIFIED FACILITIES CRITERIA - OPERATIONS AND MAINTENANCE: INSPECTION AND CERTIFICATION OF BOILERS AND UNFIRED PRESSURE VESSELS |
ASHRAE 52.2 : 2017 | METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE |
ASHRAE 194 : 2012 | METHOD OF TEST FOR DIRECT-EXPANSION GROUND-SOURCE HEAT PUMPS |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
UFC 3-400-02 : 2003 | UNIFIED FACILITIES CRITERIA - DESIGN: ENGINEERING WEATHER DATA |
CEA 709.1 : D2014 | CONTROL NETWORK PROTOCOL SPECIFICATION |
ICC 2012 INTERNATIONAL MECH. CODE : 2012 | INTERNATIONAL MECHANICAL CODE |
NFPA 88A : 2015 | PARKING STRUCTURES |
ASHRAE HDBK FUNDAMENTALS : 2013 | ASHRAE HANDBOOK - FUNDAMENTALS |
UFC 4-510-01 : Change 2 | UNIFIED FACILITIES CRITERIA - DESIGN: MILITARY MEDICAL FACILITIES |
UFC 3-430-11 : 2001 | UNIFIED FACILITIES CRITERIA - BOILER CONTROL SYSTEMS |
UFC 1-200-01 : 20071127 | UNIFIED FACILITIES CRITERIA (UFC) DOD BUILDING CODE(GENERAL BUILDING REQUIREMENTS) |
ASHRAE 62.1 : 2016 | VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY |
UFC 3-420-01 : Change 10 | UNIFIED FACILITIES CRITERIA - PLUMBING SYSTEMS |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
MIL HDBK 1027/3 : B | RANGE FACILITIES & MISCELLANEOUS TRAINING FACILITIES, OTHER THAN BUILDINGS |
UFC 3-430-08N : Change 1 | UNIFIED FACILITIES CRITERIA - CENTRAL HEATING PLANTS |
ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
FC 4-740-02F : 2013 | FACILITIES CRITERIA - AIR FORCE FITNESS CENTERS |
FC 4-722-01F : Change 1 | UNIFIED FACILITIES CRITERIA - AIR FORCE DINING FACILITIES |
MIL-STD-3007 Revision F:2006 | STANDARD PRACTICE FOR UNIFIED FACILITIES CRITERIA AND UNIFIED FACILITIES GUIDE SPECIFICATIONS |
ASHRAE 135 : 2016 | BACNET - A DATA COMMUNICATION PROTOCOL FOR BUILDING AUTOMATION AND CONTROL NETWORKS |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
UFC 3-430-02FA : Change 1 | UNIFIED FACILITIES CRITERIA - CENTRAL STEAM BOILER PLANTS |
ASHRAE 15 : 2013 | SAFETY STANDARD FOR REFRIGERATION SYSTEMS |
UFC 3-401-01 : Change 1 | UNIFIED FACILITIES CRITERIA - MECHANICAL ENGINEERING |
ASHRAE HDBK HVAC SYSTEMS & EQUIPMENT : 2012 | ASHRAE HANDBOOK - HVAC SYSTEMS AND EQUIPMENT |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.