• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

SN EN 61557-9 : 1999

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 KV A.C. AND 1.5 KV D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS

Withdrawn date

01-02-2012

Superseded by

SN EN 61557-9:2009

Published date

12-01-2013

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Requirements
5 Marking and operating instructions
      5.1 Marking
      5.2 Operating instructions
6 Tests
      6.1 Type test
             6.1.1 Response sensitivity of the insulation
                      fault location system
             6.1.2 Test current (IT)
             6.1.3 Alarm indicator
             6.1.4 Clearance and creepage distances
             6.1.5 Dielectric test
             6.1.6 Electromagnetic compatibility (EMC)
             6.1.7 Additional requirements
             6.1.8 Marking and operating instructions
      6.2 Routine tests
             6.2.1 Response sensitivity
             6.2.2 Test current (IT)
             6.2.3 Alarm indicator
             6.2.4 Dielectric test
             6.2.5 Marking and operating instructions
             6.2.6 Record of routine tests
      6.3 Example of a test matrix for type and routine
             tests
Figure 1 - Example of the components included in an insulation
           fault location system
Table 1 - Requirements for insulation fault location systems
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

TO BE USED IN CONJUNCTION WITH IEC 61557-1. Gives the requirements for insulation fault location systems which localize insulation faults in any part of the system in unearthed IT a.c. systems and unearthed IT a.c. systems with galvanically connected d.c. circuits having nominal voltages up to 1000 V a.c., as well as unearthed IT d.c. systems with voltages up to 1 500 V d.c., independent of the measuring principle.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Withdrawn
SupersededBy

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.