PREN 14179-1 : DRAFT 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
GLASS IN BUILDING - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 1: DEFINITION AND DESCRIPTION
01-07-2016
30-09-2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Glass products
5 Manufacturing processes
6 Heat soak process system
7 Fracture characteristics
8 Dimensions and tolerances
9 Edge and/or surface work, holes,
notches and cut-outs
10 Fragmentation test
11 Other physical characteristics
12 Marking
Annex A (normative) - Heat soak process system
calibration test
Annex B (informative) - Curved heat soaked thermally
toughened soda lime silicate safety glass
Annex C (informative) - Examples of particle count
Annex D (informative) - Alternative method for the
measurement of roller wave distortion
Bibliography
Defines the heat soak process system together with tolerances flatness, edgework, fragmentation and physical and mechanical characteristics of monolithic flat heat soaked thermally toughened soda lime silicate safety glass for use in buildings.
Committee |
TC 129
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
14/30310335 DC : 0 | Identical |
02/100468 DC : DRAFT JAN 2002 | Identical |
DIN EN 1096-4:2015-06 (Draft) | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
BS EN 357:2004 | Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance |
I.S. EN 1279-1:2004 | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION |
EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
DIN EN 14449:2005-07 | Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard |
I.S. EN 357:2004 | GLASS IN BUILDING - FIRE RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
DIN EN 14179-2:2005-08 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
UNI EN 14449 : 2005 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - EVALUATION OF CONFORMITY/PRODUCT STANDARD |
04/30123426 DC : DRAFT OCT 2004 | BS 6262-4 - GLAZING FOR BUILDINGS - PART 4: SAFETY RELATED TO HUMAN IMPACT - CODE OF PRACTICE |
BS EN 1096-4:2004 | Glass in building. Coated glass Evaluation of conformity/Product standard |
BS EN 14449:2005 | Glass in building. Laminated glass and laminated safety glass. Evaluation of conformity/product standard |
EN 357:2004 | Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance |
EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
02/103123 DC : DRAFT APR 2002 | BS EN 14449 - GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - EVALUATION OF CONFORMITY |
01/105367 DC : DRAFT JULY 2001 | PREN 14179-2 - HEAT SOAKED THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: EVALUATION OF CONFORMITY |
I.S. EN 1096-4:2004 | GLASS IN BUILDING - COATED GLASS - PART 4: EVALUATION OF CONFORMITY/PRODUCT STANDARD |
DIN EN 1279-1:2015-08 (Draft) | GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION |
BS EN 1279-1:2004 | Glass in building. Insulating glass units Generalities, dimensional tolerances and rules for the system description |
BS EN 14179-2:2005 | Glass in building. Heat-soaked thermally-toughened soda lime silicate safety glass Evaluation of conformity/product standard |
DIN EN 357:2005-02 | GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.