• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PD ISO/TR 4191:2014

Current

Current

The latest, up-to-date edition.

Plastics piping systems for water supply. Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O). Guidance for installation

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

28-02-2014

£260.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions, symbols, and
   abbreviations
4 Parameters influencing design
5 Hydraulic properties
6 Assembly methods
7 Storage, handling, and transport of pipes
8 Storage, handling, and transport of fittings,
   valves, and ancillaries
9 Installation
10 Commissioning by site pressure testing
11 Contaminated soil
12 Corrosion protection of metal parts
13 Pressure surge
14 Usage at lower temperature
15 Fatigue
16 Repairs
17 Pipeline detection
Annex A (informative) - - Classification of
        soils
Bibliography

Provides recommended practices for installation of unplasticized poly(vinyl chloride) (PVC-U) and oriented unplasticized poly(vinyl chloride) (PVC-O) pipes, fittings, valves, and ancillaries when used in piping systems conveying water under pressure.

Committee
PRI/88
DocumentType
Standard
Pages
56
PublisherName
British Standards Institution
Status
Current

This ISO Technical Report gives recommended practices for installation of unplasticized poly(vinylchloride) (PVC-U) and oriented unplasticized poly(vinylchloride) (PVC-O) pipes, fittings, valves, and ancillaries when used in piping systems conveying water under pressure.

The recommendations are intended to give practical guidance of design and installation of piping systems incorporating pipes, fittings, valves, and ancillary equipment made from PVC materials and used for the following purposes:

  • water mains and services buried in ground;

  • waste water under pressure;

  • conveyance of water above ground for both outside and inside buildings,

for the supply of water under pressure at approximately 20°C (cold water) intended for human consumption and for general purposes.

This Technical report is also applicable to components for the conveyance of water up to and including 45°C. For temperatures between 25°C and 45°C, Figure1 of ISO1452-2:2009 applies.

In addition, recommendations are given for the connection to fittings, valves, and ancillary equipment made from materials other than PVC.

Standards Relationship
ISO/TR 4191:2014 Identical

ISO 1452-1:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: General
EN 805:2000 Water supply - Requirements for systems and components outside buildings
ISO 1452-4:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 4: Valves
ISO 1452-3:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure Unplasticized poly(vinyl chloride) (PVC-U) Part 3: Fittings
ISO 161-1:1996 Thermoplastics pipes for the conveyance of fluids Nominal outside diameters and nominal pressures Part 1: Metric series
ISO 9080:2012 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
ISO 3:1973 Preferred numbers Series of preferred numbers
ISO 1452-5:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system
CEN/TR 1046:2013 Thermoplastics piping and ducting systems - Systems outside building structures for the conveyance of water or sewage - Practices for underground installation
DIN 18127:2012-09 SOIL, INVESTIGATION AND TESTING - PROCTOR-TEST
ISO 7387-1:1983 Adhesives with solvents for assembly of PVC-U pipe elements Characterization Part 1: Basic test methods
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes
ISO 9311-1:2005 Adhesives for thermoplastic piping systems — Part 1: Determination of film properties
ISO 4065:1996 Thermoplastics pipes Universal wall thickness table
ISO 9969:2016 Thermoplastics pipes Determination of ring stiffness
ISO 4633:2015 Rubber seals — Joint rings for water supply, drainage and sewerage pipelines — Specification for materials

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.