PD IEC/TS 60079-39:2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Explosive atmospheres Intrinsically safe systems with electronically controlled spark duration limitation
Hardcopy
20-06-2019
English
30-06-2015
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 Power-i architecture
5 Requirements for Power-i devices
6 System requirements
7 Assessment and testing
8 Marking of Power-i devices
9 Instructions
Annex A (normative) - Assessment of
Power-i safety parameters
Annex B (informative) - Explanation and
details of the Power-i basic concept
Annex C (informative) - Examples of
Power-i devices and systems
Annex D (informative) - Example of interconnection
of Power-i devices including Power-i wiring to
a Power-i system
Describes the construction, testing, installation and maintenance of Power-i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety.
Committee |
EXL/31/2
|
DevelopmentNote |
Supersedes 14/30311363 DC. (07/2015)
|
DocumentType |
Standard
|
Pages |
56
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
IEC TS 60079-39:2015(E) specifies the construction, testing, installation and maintenance of Power-i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety. This Technical Specification contains requirements for intrinsically safe apparatus and wiring intended for use in explosive atmospheres and for associated apparatus intended for connection to intrinsically safe circuits entering such atmospheres. This Technical Specification excludes the level of protection \'ia\' and the use of software-controlled circuits. This Technical Specification applies to electrical equipment utilising voltages not higher than 40 V d.c. and a safety factor 1,5 for Groups IIB, IIA, I and III. It is also applicable to Group IIC \'ic\' apparatus with a safety factor 1,0. Group IIC \'ib\' apparatus with a safety factor 1,5 are restricted to voltages up to 32 V d.c. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion of the surrounding explosive atmospheres. This Technical Specification is applicable to intrinsically safe apparatus and systems which utilise electronically controlled spark duration limitation with the aim of providing more electrical power while maintaining an adequate level of safety. This Technical Specification is also applicable to electrical equipment or parts of electrical equipment located outside hazardous areas or protected by another type of protection listed in the IEC 60079 series, where the intrinsic safety of the electrical circuits in explosive atmospheres depends on the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits located in the hazardous area are evaluated for use in such locations by applying this Technical Specification. This Technical Specification supplements and modifies the requirements of IEC 60079-0, IEC 60079-11, IEC 60079-14, IEC 60079-17 and IEC 60079-25. Keywords: Power-i apparatus, intrinsically safe apparatus and wiring intended for use in explosive atmospheres
Standards | Relationship |
IEC TS 60079-39:2015 | Identical |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |