NS EN 13786 : 2004 + A1 2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
AUTOMATIC CHANGE-OVER VALVES HAVING A MAXIMUM OUTLET PRESSURE OF UP TO AND INCLUDING 4 BAR WITH A CAPACITY OF UP TO AND INCLUDING 100 KG/H, AND THEIR ASSOCIATED SAFETY DEVICES FOR BUTANE, PROPANE OR THEIR MIXTURES
01-09-2013
12-01-2013
Foreword
1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms and definitions
3.2 Terms and definitions concerning gas
3.3 Terms and definitions concerning pressures
3.4 Terms and definitions concerning rates
4 Types of automatic change over devices
4.1 Introduction
4.2 Automatic change over devices for installations where the
final regulator supplies a pressure specified in EN 437
4.3 Other automatic change over devices installation
5 Constructional characteristics
5.1 General
5.2 Materials
5.3 Special requirements
5.3.1 Pressure sensing subassembly
5.3.2 Regulation subassembly
5.3.3 Back pressure subassembly
5.3.4 Connection subassembly
5.3.5 Supply-reserve indicator
5.3.6 Knob for selection of the operational cylinder
5.3.7 Fixing onto a wall
5.4 Mechanical strength
5.4.1 Resistance to pressure
5.4.2 Strength of connections
5.5 Soundness
5.6 Mechanical endurance
5.7 Resistance to humidity changes
5.8 Resistance to corrosion
6 Performance characteristics
6.1 General
6.1.1 Introduction
6.1.2 Supply pressure
6.2 Operational limit characteristics (regulation
function)
6.3 Operational limit characteristics (Change over
function)
6.3.1 Gas flow safety
6.3.2 Change over pressure
6.3.3 Selection of the operating cylinder
7 Test methods
7.1 General conditions
7.1.1 Type of test gas
7.1.2 Test conditions
7.1.3 Equivalence formulae
7.1.4 Test samples
7.2 Verification of constructional characteristics
7.2.1 Resistance to pressure
7.2.2 Mechanical strength of connections
7.2.3 Regulation subassembly
7.2.4 Soundness
7.2.5 Endurance
7.2.6 Resistance to humidity changes
7.2.7 Resistance to corrosion
7.3 Verification of performance characteristics
7.3.1 General
7.3.2 Plotting of regulation curves
8 Marking, packaging, instructions
8.1 General
8.2 Marking of the device
8.3 Packaging
8.4 Instructions for use and maintenance
Annex A (normative) Special requirements for automatic change
over devices fitted with pressure or rate
operated safety valves
A.1 Change over devices fitted with an over-pressure relief
A.1.1 Definition
A.1.2 Constructional characteristics
A.1.3 Performance characteristics
A.1.3.1 Automatic change over devices having a
maximum regulated pressure of up to and
including 150 mbar
A.1.3.2 Automatic change over devices having a
maximum regulated pressure exceeding 150
mbar
A.1.4 Test methods
A.1.4.1 Automatic change over devices having a
maximum regulated pressure of up to and
including 150 mbar
A.1.4.2 Automatic change over devices having a
maximum regulated pressure exceeding 150 mbar
A.1.5 Automatic change over device marking
A.2 Automatic change over device fitted with an over-pressure
shut off safety valve
A.2.1 Definition
A.2.2 Constructional characteristics
A.2.2.1 General
A.2.2.2 Closing force
A.2.2.3 Diaphragm strength
A.2.3 Performance characteristics
A.2.3.1 Automatic change over devices with a
maximum regulated pressure of up to and
including 150 mbar
A.2.3.2 Automatic change over devices with a
maximum regulated exceeding 150 mbar
A.2.4 Test methods
A.2.4.1 Test for the components transmitting the
closing forces
A.2.4.2 Test for diaphragm strength
A.2.4.3 Performance test
A.3 Automatic change over device fitted with an under-pressure
shut off safety device
A.3.1 Definition
A.3.2 Constructional and performance characteristics
A.3.3 Test methods
A.4 Automatic change over devices fitted with an excess flow
valve
A.4.1 Definition
A.4.2 Performance characteristics
A.4.3 Complementary tests for the automatic change over
devices - Test methods
A.4.4 User and maintenance instructions
A.5 Automatic change over devices fitted with a regulated
pressure limiter
A.5.1 Definition
A.5.2 Constructional and performance characteristics
A.5.3 Test methods
A.5.3.1 Test conditions
A.5.3.2 Measurement of the maximum regulated
pressure
A.5.3.3 Measurement of the pressure drop
A.5.4 Users and maintenance instructions
Annex B (normative) Special requirements for automatic change
over devices and automatic change over
devices systems for caravans and leisure
vehicles
Annex C (normative) Special requirements for low pressure
automatic change over devices under extreme
temperature conditions (temperatures below -
20 degree C)
Annex D (normative) Method for measuring leaks at test pressures
less than or equal to 16 bar
D.1 Scope
D.2 Diagram of the test
D.3 Coefficient K
D.3.1 Method
D.3.2 Calculations
D.4 Measurement of the leak
D.4.1 Method
D.4.2 Calculations
D.5 Checks
Annex E (normative) Complementary test requirements for non
metallic thermoplastic or thermal setting
materials used in the construction of
automatic change over devices
E.1 Scope
E.2 Materials
E.3 Special conditions for carrying out the test mentioned in
the body of the standard
E.3.1 Resistance to impact
E.3.2 Mechanical resistance of connections
E.3.3 Soundness
E.4 Special requirements
E.4.1 Resistance to hydrocarbons
E.4.2 Resistance to cracking under stress and when chemical
agents are present
E.4.3 Characteristics relating to fire resistance
E.4.4 Accelerated ageing
E.5 Sampling and order of tests
Annex F (normative) Requirements for elastomeric reinforced
diaphgrams
Annex G (normative) Inlet connections
Annex H (normative) Outlet connections
Annex I (normative) Test method for resistance to corrosion
I.1 Principle
I.2 Reagents
I.2.1 Saline solution
I.2.2 Compressed air
I.2.3 Salt mist
I.3 Apparatus
I.3.1 Spraying chamber
I.3.2 Sprayers
I.3.3 Heating device
I.3.4 Salt solution supply device
I.3.5 Compressed air supply device
I.3.6 Mist collectors
I.4 Test method
I.4.1 Method of exposure of automatic change over device
I.4.2 Duration of tests
I.4.3 Checks
I.4.4 Cleaning of automatic change over device
I.5 Results
Annex ZA (informative) Clauses of this European Standard addressing
essential requirements or other provisions of
EU Directives
Bibliography
Defines the constructional and operational characteristics, the safety requirements and test methods, and the marking of automatic change over devices with a capacity of less than or equal to 100 kg/h and having a maximum regulated pressure of less than or equal to 4 bar for butane, propane or their mixtures only in the vapour phase.
DevelopmentNote |
2004 Edition Re-Issued in March 2009 & incorporates AMD 1 2008. (03/2009)
|
DocumentType |
Standard
|
PublisherName |
Norwegian Standards (Norges Standardiseringsforbund)
|
Status |
Superseded
|
Standards | Relationship |
DIN EN 13786:2010-07 | Identical |
UNE-EN 13786:2005 | Identical |
UNI EN 13786 : 2009 | Identical |
BS EN 13786 : 2004 | Identical |
EN 13786:2004+A1:2008 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.