Chapter 1 General
1.1 Scope
1.2 Purpose
1.3 Existing Facilities
1.4 Definitions
Chapter 2 Construction Requirements
2.1 General Requirements
2.2 Interior Surfaces
2.3 Wall Construction
2.4 Roof Construction
2.5 Bins and Tanks
2.6 Stairs, Elevators, and Manlifts
2.7 Marine Towers
Chapter 3 Ventilation, Venting, and Aeration
3.1 General
3.2 Venting of Bins and Tanks
Chapter 4 Explosion Relief and Venting
4.1 Scope
4.2 Requirements for Enclosures
4.3 Requirements for Equipment
Chapter 5 Equipment
5.1 Elevator Legs
5.2 Processing Machinery
5.3 Clutches and Drive Belts
5.4 Screw Conveyors and En Masse-Type Conveyors
5.5 Bearings
5.6 Spouts and Throw of Grain
Chapter 6 Grain Dryers
6.1 General
6.2 Location
6.3 Construction
6.4 Air Heating Systems
6.5 Safety Controls
6.6 Dryer Operation
6.7 Fire Protection
Chapter 7 Heated Devices and Processes
7.1 Heat Transfer Systems
7.2 Comfort Heating
Chapter 8 Dust Control
8.1 Dust Emissions
8.2 Dust Collection Systems
Chapter 9 Fire Protection
9.1 Standpipe and Hose
Chapter 10 Fumigation
10.1 Definitions
10.2 Regulatory Usage
10.3 Fire Hazards
10.4 Fire and Explosion Protection
10.5 Storage and Handling
10.6 Hazard Warning
Chapter 11 Supplemental Requirements
11.1 Electrical Wiring and Equipment
11.2 Cutting and Welding
11.3 Smoking
11.4 Miscellaneous Storage
11.5 Storage of Oils, Flammable Liquids, and LP-Gas
Chapter 12 Supplemental Miscellaneous Requirements
12.1 Dryer Operation
12.2 Removal of Static Dust
12.3 Dust Collection System
12.4 Fire Protection
12.5 Cutting and Welding
12.6 Propellant Actuated Tools
12.7 Engine and Motor Driven Equipment
12.8 Smoking
Chapter 13 Referenced Publications
Appendix A
Appendix B Supplementary Information on Fire Protection
Appendix C Employee Health and Safety
Appendix D Referenced Publications
Index
Outlines updated practices to prevent dust explosions and to minimize damage if an explosion should occur.
DocumentType |
Standard
|
PublisherName |
National Fire Protection Association
|
Status |
Superseded
|
SupersededBy |
NFPA 650 : 1998 | PNEUMATIC CONVEYING SYSTEMS FOR HANDLING COMBUSTIBLE PARTICULATE SOLIDS |
NFPA 497B : 1991 | RECOMMENDED PRACTICE FOR THE CLASSIFICATION OF CLASS II HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 61D : 1989 | PREVENTION OF FIRE AND DUST EXPLOSIONS IN THE MILLING OF AGRICULTURAL COMMODITIES FOR HUMAN CONSUMPTION |
NFPA 61A : 1989 | PREVENTION OF FIRE AND DUST EXPLOSIONS IN FACILITIES MANUFACTURING AND HANDLING STARCH |
NFPA 61C : 1989 | PREVENTION OF FIRE AND DUST EXPLOSION IN FEED MILLS |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
NFPA 31 : 2016 | INSTALLATION OF OIL-BURNING EQUIPMENT |
NFPA 58 : 2017 | LIQUEFIED PETROLEUM GAS CODE |
NFPA 71 : 1989 | INSTALLATION, MAINTENANCE, AND USE OF SIGNALING SYSTEMS FOR CENTRAL STATION SERVICE |
NFPA 505 : 2013 | FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS |
NFPA 101 : 2018 | LIFE SAFETY CODE |
NFPA 69 : 2014 | EXPLOSION PREVENTION SYSTEMS |
NFPA 255 : 2006 | TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS |
NFPA 650 : 1998 | PNEUMATIC CONVEYING SYSTEMS FOR HANDLING COMBUSTIBLE PARTICULATE SOLIDS |
NFPA 704 : 2017 | STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS FOR EMERGENCY RESPONSE |
NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA 10 : 2018 | PORTABLE FIRE EXTINGUISHERS |
NFPA 68 : 2013 | EXPLOSION PROTECTION BY DEFLAGRATION VENTING |
NFPA 72E : 1990 | AUTOMATIC FIRE DETECTORS |
NFPA 14 : 2016 | INSTALLATION OF STANDPIPE AND HOSE SYSTEMS |
NFPA 86 : 2015 | OVENS AND FURNACES |
NFPA 220 : 2018 | TYPES OF BUILDING CONSTRUCTION |
NFPA 51B : 2014 | FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
NFPA 601 : 2015 | SECURITY SERVICES IN FIRE LOSS PREVENTION |
NFPA 13 : 2016 | INSTALLATION OF SPRINKLER SYSTEMS |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 72A : 1987 | INSTALLATION, MAINTENANCE, AND USE OF LOCAL PROTECTIVE SIGNALING SYSTEMS |
NFPA 77 : 2014 | STATIC ELECTRICITY |
NFPA 490 : 2002 | CODE FOR THE STORAGE OF AMMONIUM NITRATE |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
NFPA 72C : 1986 | INSTALLATION, MAINTENANCE, AND USE OF REMOTE STATION PROTECTIVE SIGNALING SYSTEMS |
ASME B56.1 : 2004 | SAFETY STANDARD FOR LOW LIFT AND HIGH LIFT TRUCKS |
NFPA 80 : 2016 | FIRE DOORS AND OTHER OPENING PROTECTIVES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.